Service Manual
41
Raption
Backflow diode and Clixon
E
Backflow diode protects the internal components of the
Raption
from any current that
could come from the oposite side, from the EV to the Charging Station.
This may occur in case there is a problem balancing the voltages, either on the EV or in
the Charging Station side.
In order to keep a safe temperature in this zone, it is installed a radiator and a fan.
Additionally, it is installed a Clixon. This component will notify the Mode 4 board in case
temperature in this zone is above 80ºC. This alarm will generate an error that will stop
any live charging session and will keep the unit out of service until problem is fixed.
Model for Raption 50
Model for Raption 50 HV, Raption 50 EVO
and Raption 100