1.- 

SAFETY PRECAUTIONS 

Follow the warnings described in this manual with the symbols shown below. 
 

 

DANGER 
Warns of a risk, which could result in personal injury or material damage. 

 

 

ATTENTION 
Indicates that special attention should be paid to a specific point. 

 

If you must handle the unit for its installation, start-up or maintenance, the following should 
be taken into consideration: 

 

Incorrect  handling  or  installation  of  the  unit  may  result  in  injury  to  personnel  as 

well  as  damage  to  unit.  In  particular,  handling  with  voltage  applied  may  result  in 

electric  shock,  which  may  cause  death  or  serious  injury  to  personnel.  Defective 

installation or maintenance may also lead to the risk of fire.  

Carefully  read  the  manual  prior  to  connecting  the  unit.  Follow  all  the  installation 

and maintenance instructions for the unit throughout its working life. In particular, 

follow  the  installation  standards  indicated  in  the  Low  Voltage  Directive  and 

additional technical instructions.  

The installation, operation and maintenance of LV units must only be carried out by 

authorised  installers.  LV  regulations  (Art.  22)  specifically  define  the  requirements 

that authorised installers must meet. 

If in order to install the unit,  you must work in areas that have high-voltage  (HV) 

units installed, then the personnel handling units in this area must be authorised to 

work  in  HV  installations.  See  National  Electric  Code  55/2004 dated  18-06-2004, 

which regulates the requirements and the operation of high-voltage installation and 

maintenance companies.

 

 

2.- 

PRODUCT DESCRIPTION 

 

2.1.- DESCRIPTION 

Step and contact analyzer based on current injection during one network cycle. Provides up to 50 
A to a maximum recommended earthing resistance of 10 ohms. Remote control via telephone and 
Bluetooth communication. The unit's software is easily updated and customized.  
 
 
 
 
 

Summary of Contents for Getest

Page 1: ...INSTRUCTION MANUAL M98224701 03 13A...

Page 2: ...has the skills and knowledge related to the construction and operation of the electrical equipment and installations and who has received safety training on the hazards involved WARNING Consult the i...

Page 3: ...as a cabo exclusivamente por pessoal qualificado O C digo El ctrico Nacional define uma pessoa qualificada como uma pessoa que se encontre familiarizada com a constru o e opera o do equipamento assim...

Page 4: ...______________________________________________ 9 5 1 PERFORMANCE FEATURES ________________________________________________________9 5 2 ELECTRICAL FEATURES ____________________________________________...

Page 5: ...the unit throughout its working life In particular follow the installation standards indicated in the Low Voltage Directive and additional technical instructions The installation operation and mainte...

Page 6: ...he instrument has two ergonomic handles and we recommend it be carried by two people The device also includes two electrodes These weigh 25 kg each This weight may be harmful if it is not lifted If th...

Page 7: ...libration certificate Samsung Galaxy Young telephone with all its components charger box etc Cocodrile clamp Cable to connect the weights Measuring pick 2 switches Instruction Manual If any problem is...

Page 8: ...The centre of gravity of some units may be found at a considerable height Therefore when handling with a forklift it is recommended that the unit be securely fastened and that no abrupt operations are...

Page 9: ...ications to the device or the unit specifications set out in this instruction manual without prior notice CIRCUTOR SA advises the user to obtain the device s latest version of the specifications and a...

Page 10: ...nt 15 Aac You need a low impedance power supply line to get maximum performance given that peaks of up to 130 A for 20 ms may appear when applying maximum power We recommend using cable with a cross s...

Page 11: ...Compliance The device complies with EU directives LVD 2006 95 EC and EMC 89 336 EEC Due to the nature of the device an injection of several amps will cause some disturbances in the power supply lines...

Page 12: ...nical service representative 6 1 INSTALLATION The Getest may be powered directly from the mains 230 Vac and 50 60 Hz or from a single phase generator set The required power of the generator set will d...

Page 13: ...to perform the test as well as the current and voltage coils supplied with the unit 6 2 UNIT PARTS GETEST Wiring Max R 5A Max R 10A Max R 25A Max R 50A Power on indicator Safety switch 20 A D curve c...

Page 14: ...GETEST Page 14 of 24 PDA Android PDA Windows Mobile...

Page 15: ...the device to a line or generator capable of supplying the required power Required power 600 V x current to be injected 3 Flip the switch 6 The red LED will light up 4 Before connecting the telephone...

Page 16: ...switch 5 to the Enabled position 9 Select the testing mode resistance step or contact If you select resistance you must indicate the test current In step and contact mode you must indicate the maximu...

Page 17: ...nal b Current output contactor connection c Erratic voltage measurement d Test at 25 Vac e Injection of as a minimum the required current f Increased voltage if the desired current is not reached g In...

Page 18: ...t must not exceed 10 Hardware earthing detail You must find or build a good auxiliary earthing as it will determine whether the unit can inject the test current Bearing in mind that the ohmic value of...

Page 19: ...yellow green to the Getest s voltage terminals yellow green Run the other end to the weights one cable for each weight Arrange the weights one metre apart from each other simulating the passage of a p...

Page 20: ...or substation Once the connections are made select step voltage mode in the PDA and enter the maximum fault current value provided by the supply company 7 2 CONTACT VOLTAGE To perform the contact test...

Page 21: ...contact or resistance the auxiliary earth must be good enough to allow a correct measurement Bear in mind that a poor auxiliary earth adds a series resistance to the circuit which reduces the MPC dev...

Page 22: ...oid version 1 Connect your telephone to the computer with a USB cable 2 Enable the phone s connection to the computer 2 Enter in My PC and select the Removable device icon 3 Open the desired file 9 WA...

Page 23: ...ontinue There is a risk of electric shock The loop resistance is too high for the requested current MPC will apply the maximum power but will not be able to reach the required value Error impossible t...

Page 24: ...to LV Regulations or that surpasses the limits indicated in the technical and environmental features of this manual In particular capacitor units are very sensitive to adverse environmental condition...