30
CIRWATT B 400
Instruction Manual
Table 5:L1 screen�
Screens
Text
Observations
L1
L11
ACTUAL
Access the current values of contract 1
L12
CIer 1
Access the closing 1 (most recent) values for contract 1
L13
CIer 2
Access the closing 2 values for contract 1
L14
CIer 3
Access the closing 3 values for contract 1
L15
CIer 4
Access the closing 4 values for contract 1
L16
CIer 5
Access the closing 5 values for contract 1
L17
CIer 6
Access the closing 6 (oldest) values for contract 1
Atras
Return to previous screen
Screen L11 (CONTRACT 1: CURRENT)
This screen shows the information on the current values for contract 1. When you go into this menu,
two data display options are shown: absolute values and incremental values.
The option
ABSOLUTE
(
ABS
)
displays the absolute values of active and reactive energy, in addition to
excess power and maximums demands.
The option
INCREMENTAL
(
INC
)
displays the incremental values, from the latest billing closing, for
active and reactive energy, as well as for excess power and maximums. If no option is selected, after
the next press, the data will be displayed by default using Absolute values.
On either of the two screens, the information will only be displayed when it is active, meaning if certain
tariffs or certain records, such as excess or maximums, have not been activated, the information on
said tariffs or records will not be shown on the screen.
Below are the codes for the Absolute values:
Table 6: Absolute values�
L11
ABS
Absolute values
OBIS
KWH
1
.
18
.
1
Tariff periods for Active Energy since measuring began (if
active), including the total (period 0)
1.18.x where x = tariff (period)
KWH
1
.
18
.
2
KWH
1
.
18
.
3
KWH
1
.
18
.
4
KWH
1
.
18
.
0
KVARL
1
.
58
.
1
Tariff periods for Reactive Energy Q1 since measuring began
(if active), including the total (period 0)
1.58.x where x = tariff (period)
KVARL
1
.
58
.
2
KVARL
1
.
58
.
3
KVARL
1
.
58
.
4
KVARL
1
.
58
.
0
Excess Power
1
.
12
.
1
Excesses since close of last billing period (if active)
1.12.x where x = tariff (period)
Excess Power
1
.
12
.
2
Excess Power
1
.
12
.
3
Excess Power
1
.
12
.
4
MAXIMUMS
1
.
16
.
1
Maximums (if active) since close of billing period, including
the total (period 0)
1.16.x where x = tariff (period)
MAXIMUMS
1
.
16
.
2
MAXIMUMS
1
.
16
.
3
MAXIMUMS
1
.
16
.
4
MAXIMUMS
1
.
16
.
0