7
7. Finalizing the Fitting Make-up
7.1
Insert the end with pre-set ferrules and nut into
the fi tting. Thread and rotate the nut until hand-tight.
While supporting the fi tting body, tighten the nut
with a wrench
1
⁄
2
turn for tubing up to 1” (25mm).
For tubing greater than 1” (25mm)
3
⁄
4
turn is required.
The initial fi tting make-up is now complete.
8. Dismantle & Store Unit
8.1
Open the Hand pump release valve.
8.2
Remove the Die and Jig from the Pre-Setting head
by fi rst unscrewing the Die-Fixing bolt, using the 5mm Hex
wrench
provided.
8.3
Remove the Die-Fixing bolt and store in a safe place.
Unscrew the Jig along with the Die, turning it
counter-clockwise, using the wrench provided.
8.4
Disconnect the hand pump hose from the female
coupler on the Pre-Setting head by loosening the coupler collar.