background image

 

 

8

8

 
6.

 

Remove ball bearing (11) from power rotor (7) by first removing retaining ring (15) from groove in 
power rotor (7) shaft. Ball bearing (11) can then be removed with a gear puller or arbor press.  

 

 

CAUTION 

 

Removal of bearing by force applied to its outer ring could damage bearing. 

 
NOTE: Imo Pump strongly recommends replacing ball bearing each time it’s pressed off power rotor. 
 
7.

 

Note inlet cover (2) indexing. Remove inlet head

 

(2) by removing four bolts (3).  

 

8.

 

Remove O-ring (26) from inlet head (2). 

 

9.

 

If steel pump, remove break down bushing (19) from inboard cover (4). 

 

PUMP REASSEMBLY: 
 
See seal drawings (Figures 2 and 3) and assembly drawings (Figures 4 and 5) 

 

NOTE:  Prior to pump assembly, all parts should be cleaned and inspected for nicks, burrs or gouges. 
 

When ready for assembly, wipe all parts, including bolts, O-rings and seal faces with clean, 

 

lubricating oil or pumped product, if applicable. 

 

 

CAUTION 

 

Bearing service life could be significantly reduced if bearing is pushed on by its outer race

 

1.

 

Install ball bearing

 

(11)

 

onto shaft (7) using an arbor press and sleeve by pushing on ball bearing (11) 

inner race only until ball bearing (11) is positioned against shoulder on power rotor (7). 

 
2.

 

Install retaining ring (15) in groove in power rotor (7). 

 
3.

 

Before installing seal (16), insure power rotor (7) shaft is clean and has no burrs or sharp edges.  

 

4.

 

If seal has elastomeric rubber bellows, (see figure 2)

, apply light film of oil to bore of bellows and install 

rotating assembly {16A} on power rotor (7) shaft with a twisting motion by pushing on seal retainer only 
with fingers. Do not touch carbon face with fingers. Clean carbon face of seal with alcohol and lint free 
cloth. Apply light film of clean lubricating oil to carbon face. 

 
5.

 

If seal is metal bellows type, (see figure 3)

, apply a light film of oil to rotating seat O-ring of seal and slide 

rotating assembly {16A} on power rotor shaft (7). Tighten setscrews {16C} Do not touch carbon seal face 
with fingers. Clean carbon face of seal with alcohol and lint free cloth. Apply light film of clean lubricating 
oil to carbon face. 

 

6.

 

Apply light film of clean lubricating oil on seat and O-ring of stationary seat {16B} of mechanical seal 
Install stationary seat {16B} into bore in inboard cover (4) with fingers (do not touch seal face with any 
tools) so slot in face of seal is facing into inboard cover (4). Be sure stationary seat {16B} is all the way 
to bottom of bore in inboard cover (4) and slot in seal mates up to pin (95) in inboard cover (4). 

 
7.

 

Clean stationary seat of mechanical seal (16A) in inboard cover (4) with alcohol and soft, lint free cloth, and 
apply light film of clean lubricating oil to carbon face. 

 

Summary of Contents for AA3G/NVPKFB187SP000

Page 1: ...Installation Operation Maintenance and Troubleshooting Manual No SRM00046 this manual and associated component manuals supplied with the unit should be read thoroughly prior to pump installation star...

Page 2: ...this box could cause damage or failure of the equipment Non compliance of safety instructions identified by the following symbol could affect safety for persons Safety instructions where electrical s...

Page 3: ...ough 250 Imo Pumps This pump series has been designed for general use in lubricating seal and distillate fuel oil applications Size and construction of each pump is identified in model number on pump...

Page 4: ...ure filtration duty cycle drive type mounting etc are interrelated Due to these variable conditions specific application limits may be different from operational limitations This equipment must not be...

Page 5: ...y 4 1 Inboard Cover 21 4 Bolt Foot Mt Pumps Only 7 1 Shaft 26X 1 Inlet Cover O Ring 8 2 Idler Rotor 31X 1 Inboard Cover O Ring 11X 1 Ball Bearing 47 1 Pipe Plug 2 on Weep Hole Pumps 13 1 Key 95 1 Pin...

Page 6: ...CAUTION ATTENTION Fluid leakage from disassembly of pump may make floor slippery and cause personal injury The following steps are required before starting any maintenance action A De energize and loc...

Page 7: ...it is withdrawn from housing so the idlers will not be dropped on floor 3 Remove power rotor 7 and idlers 8 by grasping shaft of power rotor and easing it out of housing 1 Set rotors aside 4 For Elast...

Page 8: ...n power rotor 7 3 Before installing seal 16 insure power rotor 7 shaft is clean and has no burrs or sharp edges 4 If seal has elastomeric rubber bellows see figure 2 apply light film of oil to bore of...

Page 9: ...tup For detailed instructions regarding installation alignment operation and trouble shooting see General Installation Operation Maintenance Troubleshooting Manual CA 1 FIELD AND FACTORY SERVICE AND P...

Page 10: ...10...

Page 11: ...11...

Page 12: ...2 CIRCOR 1710 Airport Road 28110 PO Box 5020 Monroe NC USA 28111 5020 Tel 1 877 853 7867 Fax 1 704 289 9273 Email cc circor com Web www circorpt com 2020 CIRCOR Pumps North America LLC All rights rese...

Reviews: