7

7

 

 

CAUTION

 

 

ATTENTION

 

 

When removing inboard cover (4) from pump in step 1, below, DO NOT pull out rotors (7 & 8) 
They may drop to floor and be damaged. If rotors start to come out, hold them in place.

 

 

1.

 

Remove bolts (3) from inboard cover (4) and then remove inboard cover (4) from pump housing (1).  

 

2.

 

Remove stationary seat {16B} of seal (16), on pumps with seals, and O-ring (31) from inboard cover (4).  

 

 

CAUTION

 

 

ATTENTION

 

 

In next step, the rotors will be removed from pump. They will come out as a unit.  Use care to 
support rotor set as it is withdrawn from housing so the idlers will not be dropped on floor

 

 
3.

 

Remove power rotor (7) and idlers (8) by grasping shaft of power rotor and easing it out of housing (1). Set 
rotors aside. 

 

4.

 

For Elastomeric Bellows Type Seals (see Fig 2 below) – Slide rotating assembly {16A} of mechanical seal 
off of power rotor (7) with rotating motion. 

 

5.

 

For Metal Bellows Type Seals (see Fig 3 below) – Loosen set screw {16C}and slide rotating assembly 
{16A} from power rotor (7). 

.062

METAL BELLOWS MECHANICAL SEAL

 

                   Figure 3                                                              Figure 2 
 

NOTE: If only replacing seals, pump disassembly is complete. For mechanical seal installation, 
complete steps 3 through 12 in reassembly procedure. If remainder of pump needs to be disassembled, 
proceed below. 

Summary of Contents for AA3G/NVPKFB187SP000

Page 1: ...Installation Operation Maintenance and Troubleshooting Manual No SRM00046 this manual and associated component manuals supplied with the unit should be read thoroughly prior to pump installation star...

Page 2: ...this box could cause damage or failure of the equipment Non compliance of safety instructions identified by the following symbol could affect safety for persons Safety instructions where electrical s...

Page 3: ...ough 250 Imo Pumps This pump series has been designed for general use in lubricating seal and distillate fuel oil applications Size and construction of each pump is identified in model number on pump...

Page 4: ...ure filtration duty cycle drive type mounting etc are interrelated Due to these variable conditions specific application limits may be different from operational limitations This equipment must not be...

Page 5: ...y 4 1 Inboard Cover 21 4 Bolt Foot Mt Pumps Only 7 1 Shaft 26X 1 Inlet Cover O Ring 8 2 Idler Rotor 31X 1 Inboard Cover O Ring 11X 1 Ball Bearing 47 1 Pipe Plug 2 on Weep Hole Pumps 13 1 Key 95 1 Pin...

Page 6: ...CAUTION ATTENTION Fluid leakage from disassembly of pump may make floor slippery and cause personal injury The following steps are required before starting any maintenance action A De energize and loc...

Page 7: ...it is withdrawn from housing so the idlers will not be dropped on floor 3 Remove power rotor 7 and idlers 8 by grasping shaft of power rotor and easing it out of housing 1 Set rotors aside 4 For Elast...

Page 8: ...n power rotor 7 3 Before installing seal 16 insure power rotor 7 shaft is clean and has no burrs or sharp edges 4 If seal has elastomeric rubber bellows see figure 2 apply light film of oil to bore of...

Page 9: ...tup For detailed instructions regarding installation alignment operation and trouble shooting see General Installation Operation Maintenance Troubleshooting Manual CA 1 FIELD AND FACTORY SERVICE AND P...

Page 10: ...10...

Page 11: ...11...

Page 12: ...2 CIRCOR 1710 Airport Road 28110 PO Box 5020 Monroe NC USA 28111 5020 Tel 1 877 853 7867 Fax 1 704 289 9273 Email cc circor com Web www circorpt com 2020 CIRCOR Pumps North America LLC All rights rese...