background image

 

 

3

3

GENERAL INSTRUCTIONS 

 

These instructions cover disassembly, assembly and parts identification of AA3G-187 thru 250 Series, 
Imo Pumps. 

 

NOTE: Individual contracts may have specific provisions that vary from manual.  For further detailed 
information and technical assistance to questions not answered by these manuals, please refer to Imo 
Pump, Technical/Customer Service Department, at (704) 289-6511.

 

This manual cannot cover every situation connected with installation, operation, inspection, and maintenance 
of equipment supplied.  Every effort was made to prepare text of manual so that engineering and design data 
is transformed into the most easily understood wording.  Imo Pump must assume personnel assigned to 
operate and maintain supplied equipment and apply this instruction manual have sufficient technical 
knowledge and experience to apply sound safety and operational practices that may not be otherwise covered 
by this manual. 
 

 

WARNING

 

 

If installation, operation, and maintenance instructions are not correctly and strictly followed and 
observed, injury to personnel or serious damage to pump could result. Imo Pump cannot accept 
responsibility for unsatisfactory performance or damage resulting from failure to comply with 
instructions. 

 

INTRODUCTION

 

This manual covers series AA3G-187 through 250 Imo Pumps.  This pump series has been designed for 
general use in lubricating, seal and distillate fuel oil applications. Size and construction of each pump is 
identified in model number on pump nameplate.  Definitions of model designators are identified below. 

 

                  AA   3G  /  N   V   P   K   F   B     187SP   000 

 

Design Version 

 

 

Special Pump Designator 

Pump Series

 

 

 

 

 

 

 

 

 

 

Size / Lead / Rotation

 

Separator

       187SY 

1.45D 

CW 

250AL 

1.3D 

CW

 

 

187SZ = 1.45D CCW 

250AM = 1.3D CCW

 

Hardened Screw Set     N

 = No 

187SM = 1.75D CW 

250SP = 1.6D CW 

   

187SN = 1.75D CCW 

250SR = 1.6D CCW

 

Seals

   

187SC = 2.0D CW 

250SC = 2.0 CW   

V

 = Fluorocarbon (Viton) Elastomer Bellows Mech.

 

187SD = 2.0D CCW 

250SD = 2.0D CCW 

       Seal, carbon on Ni-Resist, Viton, 0-Ring Seat

 

200SC = 2.0D CW

 

H

 = Metal Bellows, Balanced Mech. Seal, 

200SD = 2.0D CCW 

  Carbon on silicon carbide. Viton, O-ring seat 

J

 = Metal Bellows, Balanced Mechanical Seal, 

 

 

Relief Valve Set Range (

Not available on steel version.)

  

  Carbon on silicon carbide, Neoprene, O-ring seat 

= No Seal, Fluorocarbon (Viton) O-rings   

 

 

A

 = No Relief Valve 

   

B

 = 60 or 75 psig Differential 

Case Materials

 

C

 = 90, 105,120 psig Differential 

P

 = Iron with SAE 4-Bolt Pad Discharge Port  

 

 

D

 = 135, 150,165 psig Differential 

S

 = Steel with SAE 4-Bolt Pad Discharge Port 

 

 

E

 = 175, 190, 210, 225, 240 psig diff. 

 

Inlet Type 

Mounting 

K

 = Axial with SAE 4-Bolt Pad (Seal-less pump only) 

=

 

SAE 4 bolt flange mount 

M

 = Radial with SAE 4-Bolt Pad (Seal-less pump only) 

F

 = Foot Mounted 

P

 = Axial with SAE 4-Bolt Pad and Weep Hole

 

 

 

I

   = Integral Flange Mount (Used With No Seal)

  

= Radial with SAE 4-Bolt Pad and Weep Hole

 

 

Summary of Contents for AA3G/NVPKFB187SP000

Page 1: ...Installation Operation Maintenance and Troubleshooting Manual No SRM00046 this manual and associated component manuals supplied with the unit should be read thoroughly prior to pump installation star...

Page 2: ...this box could cause damage or failure of the equipment Non compliance of safety instructions identified by the following symbol could affect safety for persons Safety instructions where electrical s...

Page 3: ...ough 250 Imo Pumps This pump series has been designed for general use in lubricating seal and distillate fuel oil applications Size and construction of each pump is identified in model number on pump...

Page 4: ...ure filtration duty cycle drive type mounting etc are interrelated Due to these variable conditions specific application limits may be different from operational limitations This equipment must not be...

Page 5: ...y 4 1 Inboard Cover 21 4 Bolt Foot Mt Pumps Only 7 1 Shaft 26X 1 Inlet Cover O Ring 8 2 Idler Rotor 31X 1 Inboard Cover O Ring 11X 1 Ball Bearing 47 1 Pipe Plug 2 on Weep Hole Pumps 13 1 Key 95 1 Pin...

Page 6: ...CAUTION ATTENTION Fluid leakage from disassembly of pump may make floor slippery and cause personal injury The following steps are required before starting any maintenance action A De energize and loc...

Page 7: ...it is withdrawn from housing so the idlers will not be dropped on floor 3 Remove power rotor 7 and idlers 8 by grasping shaft of power rotor and easing it out of housing 1 Set rotors aside 4 For Elast...

Page 8: ...n power rotor 7 3 Before installing seal 16 insure power rotor 7 shaft is clean and has no burrs or sharp edges 4 If seal has elastomeric rubber bellows see figure 2 apply light film of oil to bore of...

Page 9: ...tup For detailed instructions regarding installation alignment operation and trouble shooting see General Installation Operation Maintenance Troubleshooting Manual CA 1 FIELD AND FACTORY SERVICE AND P...

Page 10: ...10...

Page 11: ...11...

Page 12: ...2 CIRCOR 1710 Airport Road 28110 PO Box 5020 Monroe NC USA 28111 5020 Tel 1 877 853 7867 Fax 1 704 289 9273 Email cc circor com Web www circorpt com 2020 CIRCOR Pumps North America LLC All rights rese...

Reviews: