background image

 

22 

 

 
 
Accessories & Spare Parts 

 

 

 
 
 
 
 
For more information about CPX products and accessories please see 

www.cipax.com

 

Contact your local retailer for updated prices. 

 

         

 

 

 

 

 

 

 

Part No.

 

Description 

Comment 

67502 

CPX Rubber sealing Ø 110 mm 

Rubber sealing för Ø110 mm sewage pipe 

45022 

CPX Lid, childproof, Ø 600mm 

For CPX extension neck och 600 pipe 

450251 

CPX Extension neck, H=250 mm 

Including assembly kit 

450501 

CPX Extension neck, H=400 mm 

Including assembly kit 

450121 

CPX Extension neck, H=550 mm 

Including assembly kit 

450141 

CPX Extension neck, telescope H=580-850 mm 

Adjustable, Including assembly kit 

63265 

CPX Rubber sealing for corrugated 600 mm pipe 

Must be used with Ø 600 mm pipe 

606171 

CPX Level alarm 

Alarm for high level  

606181 

CPX Level alarm, wireless 

Wireless alarm for high level 

62365 

CPX Ventilation valve with active coal 

75/110mm 1500L/h 

62366 

CPX Ventilation valve with active coal 

160mm 7000L/h 

62367 

CPX Refill, active coal 

75/110mm 1500L/h 

62368 

CPX Refill, active coal 

160mm 7000L/h 

45019 

CPX Pump-kit, including pump chamber 

If infiltration is placed higher than the tank 

230281 

CPX Infiltration Module 14 m² 

14 m² Infiltration bed 

Summary of Contents for 23012

Page 1: ...1 CPX Slamavskiljare 1200L CPX Septic tank 1200L Installation och anv ndarhandbok Installation and user manual Utg va 2 Edition 2 www cipax se...

Page 2: ...gjuten polyetenplast Locket r testat och godk nt av SP numera RISE enligt Boverkets handbok om Barns kra brunnar och SP metod 0487 genomtrampningsprov utg va 3 Slamavskiljaren levereras ven med ett f...

Page 3: ...___________________________________________ F rh jningshals h jd 550mm Avst nd vatteng ng till toppen av halsen 770mm CPX art nr 450121 RSK 6251199 ____________________________________________________...

Page 4: ...ga h jd och f sts med medf ljande skruv F r artikel 606171 borras ett 16 mm h l f r kabelgenomf ringen Grada h let Med en syl el liknande g rs ett h l i kabelgenomf ringen och kabeln kan tr s igenom H...

Page 5: ...ter hela eller delar av ret n upp till inloppsr ret Undvik mark som r sank eller l s H nsyn b r ven tas till vilket tj ldjup som r der p platsen T nk p att ____________________________________________...

Page 6: ...Dessa band placeras l mpligast ver tanken enligt skissen till h Se till att inga vassa kanter p bandl sen ligger mot tanken T nk p att Lyftkraften vid tom tank och max till ten grundvattenniv r 13500...

Page 7: ...st f rh jningshalsen med de medf ljande skruvarna Dra skruvarna f rsiktigt v xelvis tills dess att f rh jningshalsen bed ms ha bottnat mot tanken 1 G r ren anl ggningsytan p tanken och l gg en fl dig...

Page 8: ...ystemet anv nder pump ut till markb dden Slamavskiljaren med dess r rdragning m ste ha en bra ventilation f r att fungera tillfredsst llande Antingen via avloppet med luftning p fastighetstak eller vi...

Page 9: ...intr ffa n r avloppsvatten l ngsamt fylls p Slamavskiljaren ska aldrig st tom eller terfyllas endast med avloppsvatten n r den v l r installerad T nk p att En bra rutin r att notera n r tanken t mts S...

Page 10: ...erna Utsl pp av starka kemikalier t ex sprit reng ringsmedel kan sl ut bakterierna verdosering av tv tt eller diskmedel kan sl ut bakterierna Vatten dr neras inte fr n hush llet Kontrollera vattenniv...

Page 11: ...H 580 850 mm Justerbar inkl monteringssats 606171 CPX Niv larm Varnar f r h g niv 606181 CPX Niv larm tr dl st Varnar tr dl st om h g niv 62365 CPX Avluftningsventil med aktivt kol 75 110mm 1500L h 62...

Page 12: ...r ritning p tanken V tvolym 1200 L Vikt 85 kg inklusive lock Vatteng ng 780 mm fr n botten Till tet installationsdjup max 2000 mm Till ten grundvattenniv max 675 mm fr n tankens botten Till ten belas...

Page 13: ...tested and approved by SP according to Boverkets handbok om Barns kra brunnar and SP metod 0487 genomtrampningsprov utg va 3 The Septic Tank is also supplied with a pre mounted DN 110 outlet pipe Impo...

Page 14: ...assembly kit Accessories ______________________________________________________________________ _______________________________________________________________________ _______________________________...

Page 15: ...ipe The alarm will be activated when liquid reaches both metal surfaces at the tip The clamp can be adjusted up or down from it s position on the pipe to activate the alarm sooner or later To get the...

Page 16: ...st not under any circumstances ever go up to the inlet pipe Avoid ground that are marchy or loose Consideration should also be taken about freezing depth at wintertime Note ___________________________...

Page 17: ...anchoring canvas to prevent the Septic Tank to float up when it is empty When using bands place them as shown in the picture to the right to evenly distribute the force Do not let any band locks get i...

Page 18: ..._______________ 1 Clean the contact surface on the Septic Tank and apply a flowy string with supplied sealant in the middle and all way around 2 Clean the contact surface on the extension neck Center...

Page 19: ...ntilation When it is time for back filling and to cover over the Septic Tank it is strongly recommended to fill the Septic Tank with water simultaneously It will stabilize the Septic Tank and push bac...

Page 20: ...empty during longer time while installed or refilled only with sewage water Note Do not flush down any other waste than grey water The main task of the Septic Tank is to settle sludge from water Incom...

Page 21: ...of harsh chemicals such as alcohol cleaning agents can reduce the amount of bacteria Overdose of laundry or dishwasher detergent can reduce the amount of bacteria Water does not drain from the househ...

Page 22: ...H 550 mm Including assembly kit 450141 CPX Extension neck telescope H 580 850 mm Adjustable Including assembly kit 63265 CPX Rubber sealing for corrugated 600 mm pipe Must be used with 600 mm pipe 60...

Page 23: ...iled drawing Wet volume 1200L Weight 85 kg including the lid Water entrance 780 mm from bottom Allowed installation depth Max 2000 mm Max permitted ground water level 675 from bottom of the tank Max p...

Page 24: ...bok f r t mning Emptying log book Slamavskiljaren installerad Septic Tank installed Utf rd av Performed by Kommentar Comment Slamavskiljaren t md Septic Tank emptied Utf rd av Performed by Kommentar C...

Page 25: ...25...