Cipax 23012 Installation And User Manual Download Page 20

 

20 

 

 

Function and operation 

 

 

 

 

 

 

 

 

 

____________________________________________________________________ 

 

Start using the Septic Tank 
 

When the installation is done the Septic Tank is almost ready to get started. First make a 
quick check that it is filled with water up to the outlet pipe. If not, fill it all the way up.  
During first week of usage make a few checks that sewage comes in and water goes out and 
the level is intact to ensure the whole system works properly. 

 
 
 
 
 
 

 

_____________________________________________________________________ 

 

        

Emptying and refilling the Septic Tank 

 

The Septic Tank must be emptied in time to prevent potential escape of sludge out to the 
infiltration. It is very important the Septic Tank is filled up with water directly after sludge 
emptying. The Septic Tank must never be empty during longer time while installed or refilled 
only with sewage water. 

 
 

 

 

 
 

Note: 

Do not flush down any other waste than grey water. 

 

The main task of the Septic Tank is to settle sludge from water. 
Incoming water and sludge arriving via piping from e.g. a house is 
moving slowly through the two chambers inside.  
The two chambers are communicating via specific holes placed at a 
certain height in the smaller chamber two. Thereafter the cleaned water 
is leaving the Septic Tank via the outlet pipe alternatively using a pump. 
Avoid discharge large amount of water in a short time from e.g. a 
bathtub. Avoid oil and fat from cooking. 
Do not flush down strong chemicals or toxins.  

 

Note: 

The Septic Tank does not work if it is not filled with water all the 
way up to the outlet pipe. If it is not filled there is a risk the 
sludge will not stay in intended chamber and later on can clog 
the infiltration. 

Note: 

A good routine is to note the dates of emptying. 
See prepared logbook further back in this document. 

Summary of Contents for 23012

Page 1: ...1 CPX Slamavskiljare 1200L CPX Septic tank 1200L Installation och anv ndarhandbok Installation and user manual Utg va 2 Edition 2 www cipax se...

Page 2: ...gjuten polyetenplast Locket r testat och godk nt av SP numera RISE enligt Boverkets handbok om Barns kra brunnar och SP metod 0487 genomtrampningsprov utg va 3 Slamavskiljaren levereras ven med ett f...

Page 3: ...___________________________________________ F rh jningshals h jd 550mm Avst nd vatteng ng till toppen av halsen 770mm CPX art nr 450121 RSK 6251199 ____________________________________________________...

Page 4: ...ga h jd och f sts med medf ljande skruv F r artikel 606171 borras ett 16 mm h l f r kabelgenomf ringen Grada h let Med en syl el liknande g rs ett h l i kabelgenomf ringen och kabeln kan tr s igenom H...

Page 5: ...ter hela eller delar av ret n upp till inloppsr ret Undvik mark som r sank eller l s H nsyn b r ven tas till vilket tj ldjup som r der p platsen T nk p att ____________________________________________...

Page 6: ...Dessa band placeras l mpligast ver tanken enligt skissen till h Se till att inga vassa kanter p bandl sen ligger mot tanken T nk p att Lyftkraften vid tom tank och max till ten grundvattenniv r 13500...

Page 7: ...st f rh jningshalsen med de medf ljande skruvarna Dra skruvarna f rsiktigt v xelvis tills dess att f rh jningshalsen bed ms ha bottnat mot tanken 1 G r ren anl ggningsytan p tanken och l gg en fl dig...

Page 8: ...ystemet anv nder pump ut till markb dden Slamavskiljaren med dess r rdragning m ste ha en bra ventilation f r att fungera tillfredsst llande Antingen via avloppet med luftning p fastighetstak eller vi...

Page 9: ...intr ffa n r avloppsvatten l ngsamt fylls p Slamavskiljaren ska aldrig st tom eller terfyllas endast med avloppsvatten n r den v l r installerad T nk p att En bra rutin r att notera n r tanken t mts S...

Page 10: ...erna Utsl pp av starka kemikalier t ex sprit reng ringsmedel kan sl ut bakterierna verdosering av tv tt eller diskmedel kan sl ut bakterierna Vatten dr neras inte fr n hush llet Kontrollera vattenniv...

Page 11: ...H 580 850 mm Justerbar inkl monteringssats 606171 CPX Niv larm Varnar f r h g niv 606181 CPX Niv larm tr dl st Varnar tr dl st om h g niv 62365 CPX Avluftningsventil med aktivt kol 75 110mm 1500L h 62...

Page 12: ...r ritning p tanken V tvolym 1200 L Vikt 85 kg inklusive lock Vatteng ng 780 mm fr n botten Till tet installationsdjup max 2000 mm Till ten grundvattenniv max 675 mm fr n tankens botten Till ten belas...

Page 13: ...tested and approved by SP according to Boverkets handbok om Barns kra brunnar and SP metod 0487 genomtrampningsprov utg va 3 The Septic Tank is also supplied with a pre mounted DN 110 outlet pipe Impo...

Page 14: ...assembly kit Accessories ______________________________________________________________________ _______________________________________________________________________ _______________________________...

Page 15: ...ipe The alarm will be activated when liquid reaches both metal surfaces at the tip The clamp can be adjusted up or down from it s position on the pipe to activate the alarm sooner or later To get the...

Page 16: ...st not under any circumstances ever go up to the inlet pipe Avoid ground that are marchy or loose Consideration should also be taken about freezing depth at wintertime Note ___________________________...

Page 17: ...anchoring canvas to prevent the Septic Tank to float up when it is empty When using bands place them as shown in the picture to the right to evenly distribute the force Do not let any band locks get i...

Page 18: ..._______________ 1 Clean the contact surface on the Septic Tank and apply a flowy string with supplied sealant in the middle and all way around 2 Clean the contact surface on the extension neck Center...

Page 19: ...ntilation When it is time for back filling and to cover over the Septic Tank it is strongly recommended to fill the Septic Tank with water simultaneously It will stabilize the Septic Tank and push bac...

Page 20: ...empty during longer time while installed or refilled only with sewage water Note Do not flush down any other waste than grey water The main task of the Septic Tank is to settle sludge from water Incom...

Page 21: ...of harsh chemicals such as alcohol cleaning agents can reduce the amount of bacteria Overdose of laundry or dishwasher detergent can reduce the amount of bacteria Water does not drain from the househ...

Page 22: ...H 550 mm Including assembly kit 450141 CPX Extension neck telescope H 580 850 mm Adjustable Including assembly kit 63265 CPX Rubber sealing for corrugated 600 mm pipe Must be used with 600 mm pipe 60...

Page 23: ...iled drawing Wet volume 1200L Weight 85 kg including the lid Water entrance 780 mm from bottom Allowed installation depth Max 2000 mm Max permitted ground water level 675 from bottom of the tank Max p...

Page 24: ...bok f r t mning Emptying log book Slamavskiljaren installerad Septic Tank installed Utf rd av Performed by Kommentar Comment Slamavskiljaren t md Septic Tank emptied Utf rd av Performed by Kommentar C...

Page 25: ...25...

Reviews: