18
Mounting CPX extension neck
All CPX extension necks are mounted to the Septic Tank in identical way.
_________________________________________________________________________________
_________________________________________________________________________________
1.
Clean the contact surface on the
Septic Tank and apply a flowy
string with supplied sealant in the
middle and all way around.
2.
Clean the contact surface on the
extension neck.
Center the extension neck and
place it on the Septic Tank.
Avoid moving around the
extension neck once placed on
the tank.
3.
Mount the extension neck with the
provided screws and torque them
alternately and gently until the neck has
fully contact with the tank.
Summary of Contents for 23012
Page 25: ...25...