background image

 

International Edition, Rev. A0.9 

Summary of Contents for Fuzzyscan

Page 1: ...International Edition Rev A0 9...

Page 2: ...Revision History Rev No Released Date Description Rev A0 9 Nov 9 2020 First Release...

Page 3: ...e Warranty Cino warrants its products against defects in workmanship and materials from the date of shipment provided that the product is operated under normal and proper conditions The warranty provi...

Page 4: ...ology ID Transmission 15 Readable Barcode Setting 16 Code 39 Code 32 Setting 18 Code 39 Setting 19 Codabar NW 7 Setting 20 UPC A UPC E Setting 21 EAN Setting 24 UCC Coupon Extended Code Setting 27 IAT...

Page 5: ...Language Setting 45 Record Suffix Preamble Postamble FNC1 Symbol Character Transmission 46 Caps Lock Caps Lock Release Control 47 Delay Setting 48 Function Key Key Pad Emulation Upper Lower Case Setti...

Page 6: ...ead Duration 66 Light Source On Time Hands free Time out Good Read Duration 67 OK NG Beeping Control NG Message Output 68 Operation Control 69 Batch Reading 69 Condensed DataWizard 73 Preamble Postamb...

Page 7: ...6 Host Interface Quick Set Commands 92 Operation Mode Quick Set Commands 93 Option Codes 94 System Commands 95...

Page 8: ...f you want to change the programming family for multiple settings you need only turn over the programming page to find next desired programming family System Command The System Command is the highest...

Page 9: ...ramming procedures Each kind of programming procedure is listed in the following pages for your reference Please give careful attention to become familiar with each programming procedure If the progra...

Page 10: ...duct information and revision number to host via selected host interface then issue the completion beeping Scan M_DEFAULT FuzzyScan will recover all programmable parameters into factory preset configu...

Page 11: ...ect one option code of desired parameter Want to select another programming family Exit programming mode Enter programming mode Select one of desired programming families 1 Select one or several optio...

Page 12: ...ramming mode Scan PROGRAM Scan One of Family Codes Scan One of Option Codes Repeat Selection Scan END No Yes Scan FIN Enter programming mode Select one of desired programming families Select several o...

Page 13: ...ection MS MS MS MS MS MS MS MS MS MS IBM PS 2 25 30 series keyboard wedge interface Standard TTL RS 232 peer to peer serial USB Com Port Emulation PS 2 DOS V direct link keyboard replacement PS 2 DOS...

Page 14: ...fault S Telepen default T GS1 DataBar default X UPC E default E EAN 8 default N Trioptic Code 39 default W UCC Coupon Extended Code default Z PDF417 Micro PDF417 default V Codablock F default Y Code 1...

Page 15: ...n Code Symbol ID 1 character DS Aztec Code default e Chinese Sensible default f Australian Post default g British Post default h Intelligent Mail USPS 4CB One Code default j Japan Post default k Nethe...

Page 16: ...ology ID Transmission SS SS SS SS SS SS SS Disable symbology ID transmission Enable prefix CINO symbology ID transmission Enable suffix CINO symbology ID transmission Enable both prefix and suffix CIN...

Page 17: ...NW 7 Code 39 Trioptic Code 39 Standard Industrial 2 of 5 Matrix 2 of 5 Interleaved 2 of 5 China Postal Code Germany Postal Code Code 93 Code 11 MSI Plessey UK Plessey Telepen GS1 DataBar RSS 14 IATA P...

Page 18: ...wn symbologies only to increase the reading speed and decrease the possibility of reading error Furthermore to add the Symbology ID into the transmitted data is also helpful to identify the specific s...

Page 19: ...de 32 leading A transmission Disable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission Disable Code 39 buffering E...

Page 20: ...If you are experiencing misread of poorly printed or serious out of spec barcodes in level 1 please select level 0 Level 1 If you are experiencing misread of poorly printed or out of spec barcodes in...

Page 21: ...ol transmission Enable abcd tn e start stop symbol transmission Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission 0 1 2...

Page 22: ...leading 1 portion Enable UPC leading 1 portion 0 1 2 3 4 5 6 7 8 9 A B C D E F When enable UPC E expansion the UPC E decoded data will be converted to UPC A format and affected by related setting suc...

Page 23: ...with only 5 supplement digits Select UPC with 2 5 supplement digits Disable force supplement digits output Enable force supplement digits output UPC Family Addenda Separator Off UPC Family Addenda Sep...

Page 24: ...ng in spec UPC EAN barcodes Level 2 If you failed to read poorly printed or out of spec barcodes in level 1 please select level 2 This is the most aggressive setting and may increase the misread The S...

Page 25: ...e EAN 13 check digit transmission Disable EAN 8 check digit transmission Enable EAN 8 check digit transmission Disable ISBN ISSN Conversion reading check Enable ISBN ISSN Conversion reading check 0 1...

Page 26: ...3 0 1 2 3 4 5 6 7 8 9 A B C D The Supplement Scan Voting is the number of times the same UPC EAN with 2 5 supplement digits has to be decoded before it is transmitted It is helpful when decoding a mix...

Page 27: ...lly in characters 1 2 7 and 8 in level 1 please select level 0 Selection of this security level may significantly impair the decoding ability of the scanner Level 1 This is the default setting which a...

Page 28: ...Option Code UCC Coupon Extended Code SS SS Disable UCC Coupon Extended Code Enable UCC Coupon Extended Code 0 1 UCC Coupon Extended Code When UCC coupon extended code function is enabled scanner deco...

Page 29: ...igit verification only Enable CPN checking digit verification only Enable CPN Airline and S N check digit verification Disable check digit transmission Enable check digit transmission Disable start st...

Page 30: ...le check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 7 8 9 Code 25 Family Min Length SS MS Default 04 01 Maximum Scan 2 digits from the option code chart in Appendix then FuzzySca...

Page 31: ...endix then FuzzyScan will terminate this selection automatically FIN 2 digits Code 11 Max Length SS MS Default 98 98 Minimum Scan 2 digits from the option code chart in Appendix then FuzzyScan will te...

Page 32: ...lect MOD 10 10 check digit Select MOD 11 10 check digit Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 MSI Plessey Min Length SS MS Default 04 01 Maximum Scan 2 digits...

Page 33: ...ode 128 Setting ISBT Concatenation Off The scanner will not output ISBT concatenated barcodes ISBT Concatenation On The scanner will only decode and output ISBT concatenated barcodes The scanner will...

Page 34: ...ng SS SS Disable GS1 128 Enable GS1 128 0 1 GS1 128 Min Length SS MS Default 01 01 Maximum Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatical...

Page 35: ...lessey CLSI Format Disable Convert X to A F Enable Convert X to A F Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 7 UK Plessey Min Length SS MS Default 04 01 Maximum S...

Page 36: ...ic mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 Telepen Min Length SS MS Default 04 01 Maximum Scan 2 digits from the option code ch...

Page 37: ...chart in Appendix then FuzzyScan will terminate this selection automatically FIN 2 digits GS1 DataBar Max Length SS MS Default 74 74 Minimum Only available for GS1 DataBar Expanded Scan 2 digits from...

Page 38: ...codes UPC Composite Mode UPC never linked UPC Composite Mode UPC always linked If UPC Composite Mode UPC never linked is selected UPC barcodes are transmitted whether MicroPDF417 symbol is detected or...

Page 39: ...tically FIN 3 digits Code 16K Max Length SS MS Default 160 160 Minimum Scan 3 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically FIN 3 digits Code...

Page 40: ...rom the option code chart in Appendix then FuzzyScan will terminate this selection automatically FIN 4 digits QR Code Max Length SS MS Default 7089 7089 Minimum Scan 4 digits from the option code char...

Page 41: ...Scan 4 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically FIN 4 digits Damaged DM Code Reading SS SS SS Standard Level 1 Level 2 0 1 2 Data Matrix...

Page 42: ...SS SS Disable MaxiCode Enable MaxiCode 0 1 MaxiCode Min Length SS MS Default 01 01 Maximum Scan 3 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatica...

Page 43: ...SS Disable Aztec Code Enable Aztec Code 0 1 Aztec Code Min Length SS MS Default 01 01 Maximum Scan 4 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automat...

Page 44: ...e 0 1 2 3 4 5 US Planet Setting SS SS SS SS Disable US Planet Enable US Planet Disable Check Digit Transmission Enable Check Digit Transmission 0 1 2 3 US Postnet Setting SS SS SS SS Disable US Postne...

Page 45: ...ting F_DEFAULT Family Code Selection P C Parameter Selection Option Code Netherlands KIX Code Setting SS SS Disable Netherlands KIX Code Enable Netherlands KIX Code 0 1 Intelligent Mail Setting USPS 4...

Page 46: ...an DOS V Czech QWERTY Universal 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 99 Please refer to the ASCII HEX Table listed in the Appendix to determine HEX codes for characters symbols and fu...

Page 47: ...um 15 character input scan FIN to terminate this selection FIN 00 7F FIN FNC1 Symbol Char Transmit SS SS Disable Enable 0 1 FNC1 Symbol Char Transmit When this function is enabled and the FNC1 is cont...

Page 48: ...f 0 1 The function of Caps Lock Control is only available for IBM PC AT PS VP PS 2 series personal computers and compatible machines While selecting the other host interfaces these selections don t pe...

Page 49: ...ix then FuzzyScan will terminate this selection automatically FIN 2 digits Intermessage Delay is a time delay between messages output by FuzzyScan Increasing this delay will help host applications pro...

Page 50: ...0 1 2 Key Pad Emulation SS SS Disable key pad emulation Enable numeric output as key pad Num Lock On output 0 1 Upper Lower Case SS SS SS SS Normal case neglect the upper lower case control Inverse ca...

Page 51: ...949 Codepage 936 Codepage 932 Codepage 874 WIN1250 WIN1251 WIN1252 WIN1253 WIN1254 WIN1255 WIN1256 WIN1257 WIN1258 ISO 8859 1 Latin 1 Western European ISO 8859 2 Latin 2 Central European ISO 8859 3 L...

Page 52: ...de Output Codepage 950 Output Codepage 949 Output Codepage 936 Output Codepage 932 Output Codepage 874 Output WIN1250 Output WIN1251 Output WIN1252 Output WIN1253 Output WIN1254 Output Codepage 852 Ou...

Page 53: ...re that it also matches this language 1 Mac Device Output If your host is a Mac device select MAC Unicode Output as the scanner s output setting the data will be in Unicode You must also first ensure...

Page 54: ...15 character input scan FIN to terminate this selection FIN 00 7F FIN Postamble SS MS None 1 15 characters Maximum 15 character input scan FIN to terminate this selection FIN 00 7F FIN FNC1 Symbol Cha...

Page 55: ...yScan will terminate this selection automatically FIN 2 digits Intermessage Delay is a time delay between messages output by FuzzyScan Increasing this delay will help host applications process the inc...

Page 56: ...the host up to the preset Serial Response Time out If the scanner doesn t get a response the scanner will issue an error indication and discard the data When a NAK is received the scanner transmits th...

Page 57: ...800 BPS 2400 BPS 1200 BPS 57 6K BPS 115 2K BPS 0 1 2 3 4 5 8 9 Data Frame SS SS SS SS SS SS SS SS 8 None 1 8 Odd 1 8 Even 1 8 Space 1 8 Mark 1 8 None 2 7 Odd 1 7 Even 1 7 Space 1 7 Mark 1 7 None 2 7 O...

Page 58: ...50 WIN1251 WIN1252 WIN1253 WIN1254 WIN1255 WIN1256 WIN1257 WIN1258 ISO 8859 1 Latin 1 Western European ISO 8859 2 Latin 2 Central European ISO 8859 3 Latin 3 Southern European ISO 8859 4 Latin 4 North...

Page 59: ...t WIN1252 Output WIN1253 Output WIN1254 Output WIN1255 Output WIN1256 Output WIN1257 Output WIN1258 Output CP852 CP855 CP866 CP850 CP437 CP737 CP857 CP862 CP720 CP775 CP950 Output Little Endian CP949...

Page 60: ...may not work properly You can also choose different level of sensibility to meet your application Please refer to the setting of Image Sensing Sensitivity Force Mode Continued Power On The scanner alw...

Page 61: ...vel 5 Level 6 Level 7 0 1 2 3 4 5 6 Presentation Background Lighting Under presentation mode you can enable or disable background lighting of the scanner according to the ambient light condition Be aw...

Page 62: ...trigger mode and multiple read mode Under Regular Aiming the aiming light is turned on only when the trigger button is pressed Under Intelligent Aiming the aiming light is turned on when the scanner...

Page 63: ...rcode Reporting SS SS Disable Enable 0 1 Center Alignment When this function is enabled the scanner only decodes barcode s around aiming dot Unique Barcode Reporting This function is only effective un...

Page 64: ...n set the scanner to Scene 3 to optimize scanners motion tolerance scanning speed and scanning sensitivity Scene 4 This is also for general retail applications It optimizes the scanner s sensitivity a...

Page 65: ...zer Tone Adjust SS SS SS SS SS SS SS Buzzer tone mute Buzzer tone low Frequency 1 20 kHz Buzzer tone medium Frequency 2 70 kHz Buzzer tone high Frequency 2 81 kHz Buzzer tone extremely high Frequency...

Page 66: ...ction Option Code 1D Barcode Inverse Reading SS SS Disable Enable 0 1 With 1D Barcode Inverse Reading enabled besides traditional 1D barcode with darker lines over lighter background the scanner can a...

Page 67: ...S SS SS SS SS None 200 msec 500 msec 1 sec 1 5 sec 2 sec 3 sec 0 1 2 3 4 5 6 Good Read Duration SS SS SS SS SS Short Medium Long Extremely long Extremely short 0 1 2 3 4 The Reread Delay Double Scan V...

Page 68: ...ight source time out counter for Presentation Mode The scanner keeps the light source on till the pre defined light source on time is up You can adjust this parameter to meet your own application requ...

Page 69: ...S SS Disable OK and NG beep Enable OK and NG beep Enable OK beep while disable NG beep Enable NG beep while disable OK beep 0 1 2 3 NG Message Output SS SS SS None Message NG User defined message 1 15...

Page 70: ...e barcodes Batch Reading Rule To set the Batch Reading rule 1 Scan the PROGRAM symbol 2 Scan the Batch Reading symbol Family Code 3 Use the Option Code to define the preset Batch Reading rule 4 Scan t...

Page 71: ...to find the Hex value that represents the character s you want to match Use the Option Code to scan the alphanumeric combination that represents the ASCII characters You can match up to 4 characters w...

Page 72: ...for Code 39 9999 all lengths 42 Start character that must match for Code 39 42h B FF End of second code 09 Code identifier of Code 93 9999 Code length that must match for Code 93 9999 all lengths 43 S...

Page 73: ...g all character Also indicate end of second code 09 Code identifier of Code 93 0009 Code length that must match for Code 93 C CODE93 sample length 8 plus Suffix Symbol ID 1 9 43 Start character match...

Page 74: ...1 2 3 4 5 6 DataWizard is the most powerful Artificial Intelligence based data editing expert system provided specially for the FuzzyScan family barcode readers Through DataWizard you can process the...

Page 75: ...FIN 4th Insertion SS DS Disable Enable 2 digits identified position max 3 insertion characters FIN 2 digits position 1 3 characters FIN The Data Formatter is used to edit the scanned raw data prior t...

Page 76: ...cter SS DS Disable Enable 2 digits checking position 1 identified character FIN 2 digits position 00 7F The Data Verifier is used to provide advanced verification for error free scanning and to work a...

Page 77: ...osition 1 replacement character FIN 2 digits position 00 7F The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you to se...

Page 78: ...data excluded the data of identified position Transmitted data included the data of identified position 0 1 The Data Organizer is used to edit the scanned raw data prior to transmitting the data to t...

Page 79: ...AN 13 with 5 supplement 44 GS1 DataBar 14 EAN 8 05 GS1 DataBar Limited 22 EAN 8 with 2 supplement 35 GS1 DataBar Expanded 23 EAN 8 with 5 supplement 45 Composite Codes 24 Codabar NW 7 06 IATA 15 Code...

Page 80: ...6 Actual Output A81025 TAB SN123456 TAB 76 TAB Programming Procedure Data Verifier Scan Program to enter the programming mode Scan Verifier Control and set barcode symbology to 48 Interleaved 2 of 5...

Page 81: ...nization and set the identified position to 16 then set the data transmission to 0 forward Scan 2nd Organization and set the identified position to 17 then set the data transmission to 1 backward Scan...

Page 82: ...FuzzyScan Programming Manual Appendix 81 APPENDIX...

Page 83: ...45 is transmitted as E449123562 E212345 Code 128 Code 128 01 B C m Code 93 Code 93 09 H G m GS1 128 31 C 1 Code 11 Code 11 10 P H m Codabar Codabar NW 7 06 D F m MSI Plessey MSI Plessey 11 R M m Code...

Page 84: ...de A0 b Q m British Post British Post B1 h X 0 Micro QR Code Micro QR Code Intelligent Mail barcode Intelligent Mail barcode B3 j 0 Data Matrix Data Matrix A1 c d m Japanese Post Japanese Post B4 k 0...

Page 85: ...SHIFT Ctrl C ALT BREAK Left 04 EOT 04H CAPS LOCK Ctrl D CAPS LOCK 05 ENQ 05H NUM LOCK Ctrl E NUM LOCK 06 ACK 06H ESC Ctrl F ESC 07 BEL 07H F1 Ctrl G F1 08 BS 08H BACK SPACE Ctrl H BACK SPACE 09 HT 09...

Page 86: ...Edit Ctrl 6 LEFT Edit 31 US 1FH RIGHT Edit see below note RIGHT Edit To emulate the keyboard function key input for user definable parameters user must configure actual content using the Reserved ASC...

Page 87: ...tin American 850 Danish 850 Latvian 775 Dutch 850 Lithuanian 775 Estonian 775 Norwegian 850 English United Kingdom 850 Polish 852 English Australia 850 Portuguese 850 English Canada 850 Romanian 852 E...

Page 88: ...the Windows Registry Step 1 Open the Registry Editor You can do so by typing regedit in the Search Windows function or in Command Prompt Step 2 Go to HKEY_CURRENT_USER Control Panel Input Method Step...

Page 89: ...anual Appendix 88 Step 4 Name the new String value as EnableHexNumpad and set its Value data to 1 Step 5 Reboot the computer 2 MAC Adding Unicode Hex Input in menu bar Step 1 Go to the Apple Menu Syst...

Page 90: ...FuzzyScan Programming Manual Appendix 89 Step 2 On the Keyboard tab click on Input Sources and check the Show Input menu in menu bar box Step 3 Click the button to add an input source...

Page 91: ...Scroll to and select Others Click on Unicode Hex Input you can also use the Search function to find it When done click on the Add button Step 5 Close the Keyboard Preferences menu Step 6 Change the i...

Page 92: ...family Refer to the Hex ASCII Table you will find the HEX value of is 24 Scan the option code 2 listed on the fold out back cover Scan the option code 4 listed on the fold out back cover Scan the sys...

Page 93: ...FuzzyScan Programming Manual Appendix 92 Host Interface Quick Set Commands RS232 Serial USB Com Port Emulation USB HID Turbo Mode USB HID Standard Mode...

Page 94: ...FuzzyScan Programming Manual Appendix 93 Operation Mode Quick Set Commands Trigger Mode Presentation Mode Multiple Read Mode Force Mode...

Page 95: ...FuzzyScan Programming Manual Appendix 94 Option Codes 0 A 5 F 1 B 6 2 C 7 3 D 8 4 E 9 FIN Finish Abort END Exit...

Page 96: ...mmand the scanner will remain the pre set parameters of Host Interface Selection Keyboard Interface Control except Record Suffix Preamble Postamble Serial Interface Control except Record Suffix Preamb...

Page 97: ...FuzzyScan Programming Manual Appendix 96...

Reviews: