CV
-
100
-
P2100 Series | User Manual
102
5.2 P2100 Digital I/O (DIO) Hardware Specification
• XCOM+ / 2XCOM+ : Isolated power in V+
• XCOM- / 2XCOM- : Isolated power in V-
• Isolated power in DC voltage : 9~30V
• 8x / 16x Digital Input (Source Type)
• Input Signal Voltage Level
- Signal Logic 0 : XCOM+ = 9V,
Signal Low
-
V-
< 1V
XCOM+ > 9V,
V+
-
Signal Low
> 8V
- Signal Logic 1 : >
XCOM+
-
3V
• Input Driving Sink Current :
- Minimal : 1 mA
- Normal : 5 mA
• 8x / 16x Digital Output (Open Drain)
- DO Signal have to pull up resistor to XCOM+ for external device, the
resistance will affect the pull up current
- Signal High Level : Pull up resistor to XCOM+
- Signal Low Level : = XCOM-
- Sink Current: 1A (Max)
Summary of Contents for CV-100-P2100 Series
Page 18: ...CV 100 P2100 Series User Manual 18 Chapter 1 Product Introductions ...
Page 23: ...CV 100 P2100 Series User Manual 23 Dimensions CV 112 P2102 CV 112 P2102E ...
Page 25: ...CV 100 P2100 Series User Manual 25 Dimensions CV 115 P2102 CV 115 P2102E ...
Page 27: ...CV 100 P2100 Series User Manual 27 Dimensions CV W115 P2102 CV W115 P2102E ...
Page 29: ...CV 100 P2100 Series User Manual 29 Dimensions CV 117 P2102 CV 117 P2102E ...
Page 39: ...CV 100 P2100 Series User Manual 39 Chapter 2 Switches Connectors ...
Page 49: ...CV 100 P2100 Series User Manual 49 Chapter 3 System Setup ...
Page 73: ...CV 100 P2100 Series User Manual 73 ...
Page 75: ...CV 100 P2100 Series User Manual 75 Chapter 4 BIOS Setup ...
Page 94: ...CV 100 P2100 Series User Manual 94 Chapter 5 Product Application ...
Page 97: ...CV 100 P2100 Series User Manual 97 ...
Page 104: ...CV 100 P2100 Series User Manual 104 Reference Input Circuit Reference Output Circuit ...