Blitz 45 - 50 - 55
4-2012
54
8.1.b Fan engagement to perform the treatment
EXECUTION:
1. Disengage the power take off (PTO)
2.
Stop the tractor, remove the key from the control panel and check that
the fan is stopped.
3. Unscrew the nuts that fix the protection mobile cover and remove it to enter the release.
4. Fully press the spring push button, push the front body forward, if necessary, turning it to the right
or left, until the frontal teeth of the joint engage the corresponding teeth of the pulley; at the same
time, the spring push button must return to the outward position. This way, the body is again
integrated with the pulley, thus transmitting the movement to the fan.
5. Reposition the mobile protection cover and suitably tighten the securing nuts.
6. Start the tractor.
8.2 - FILLING THROUGH POURING FROM THE TOP
For this type of filling, use the supplementary filler (BS) located in the upper side
of the tank, towards the rear of the sprayer.
THE INLET OF THE FILLER PIPING MUST NEVER COME INTO CONTACT WITH THE ANTI-
PARASITIC MIXTURE: IT MUST ALWAYS BE KEPT AT A SAFE HEIGHT ABOVE THE TANK
FILLER AND MUST BE EQUIPPED WITH A NON-RETURN VALVE.
THE PUMP MUST NEVER RUN DRY
EXECUTION:
1. Disengage the fan (for the version where foreseen): see point 8.1.a.
2. Verify that the lever of the 3-way cock (P2) it’s in the position
“A”
.
3. For the version where foreseen: verify that the spray-line rinsing cock (P15) is on
“1”
position.
4
.
Completely open the pressure regulator (P5), by rotating counterclockwise the handle or by setting
the pressure at zero (keep the joystick on “- “ for about 15 seconds) if the atomizer is provided
with electric regulator (E5).
5. For the versions on which it is foreseen: verify that the three-way cock (P18) lever of the additional
agitation pump (P19) on “
1
”; make sure that the tap (P21) is open.
6. Close the cocks of the 2-way distributor:
a. if electric (E9), position to “
OFF
” the quick-break switches on the control panel (E10) or on the
the control unit for E.P.A. versions;
b. if manual (P9), the levers are to be lowered (horizontally positioned);
7. Close the cock (P12) by positioning the lever on “
c
”.
(on “
2
” position for E.P.A. versions).
8
.
Pour some water into the tank, for about 1/3 of its capacity, by acting from the secondary filler
(BS).
9. Start the tractor and engage the PTO; t
hen bring it up to a 500 r.p.m. rate
.
540
Use ONLY the PTO at 540 rpm. Engage the PTO with the engine of the tractor
at low speed and with maximum modularity, obtaining soft and progressive
graft and avoiding abrupt starts of the cardan shaft.
10a.
WHEN NOT USING THE MIXER (WITH MEDICINE MIXTURES OR LIQUID PRODUCTS)
10a1. Pour the mixture of water and plant protection product previously prepared (or the liquid product)
(and the possible washing water for the medicine packs and for the instruments used for
preparing the mixture) into the main filler (BP).
Summary of Contents for BLITZ 45
Page 4: ......
Page 43: ...4 2012 Blitz 45 50 55 35 01169 01171 01170...
Page 102: ...Blitz 45 50 55 4 2012 NOTES...