E20. PRESSURE SENSOR OF THE ADDITIONAL AGITATION PUMP
(On demand)
The sensor of the pressure pump, placed on the delivery cone of the additional pump sends the pump
pressure control signal to the control gearbox.
CAUTION: at starting the RED low pressure warning light is “ON” ( CHECK LAMP
function ) and it switches “OFF” while engaging the PTO.In case this warning ligh
is still “ON” during the working operation or at the PTO engagement, STOP the PTO
and check the liquid level in the main tank. In the E.P.A. versions, the warning lamp
is situated on the electronic control unit (see specific manual).
The pump pressure sensor is protected by a waterproof rubber cap. In case of
malfunctioning due to a breaking or a damage occurred to the rubber cap, replace
it immediately
P18. ADDITIONAL PUMP 3-WAY LEVER TAP
(For versions in which is envisaged)
Positioned on the pipe (T7), between the centrifugal pump (P19) and the main tank (P1),it is equipped
with a closing plug of the discharge fitting, with the relevant safety chain.
The control lever (P18) can be set to the following positions:
1 - Agitation
Le liquid gets out from the tank (P1) and is sucked by the pump (P19), then, through the delivery pipe
(T7) it returns to the tank, so provoking a further hydraulic agitation of the mixture.
The drainage is
closed.
1 - Agitation/mixing (E.P.A. versions only)
The liquid gets out from tank (P1) and is sucked by pump (P19), and, through the agitation/mixing pipe
(T8), gets back to the tank through cock (P12), which allows either the product mixing (pos. “1”) or
the hydraulic agitation of the mixture (pos. “2”).
Outlet is closed
.
00630
®
+
-
ON
ON
OFF
OFF
Spin
Remote Control
H O
2
Press.
Pump
00987
1
2
95094
cima
1
2
00989