OPERATION
Note that when the unit is powered on the mode selection control will automatically default to LIFT TIG/HF
TIG mode. This is necessary so as to prevent inadvertent arcing should an electrode holder be connected
to the unit and mistakenly be in contact with the work piece during power up.
11. Thermal Overload Indicator
This welding power source is protected by a self resetting thermostat. The indicator will illuminate if the
duty cycle of the power source has been exceeded. Should the thermal overload indicator illuminate the
output of the power source will be disabled. Once the power source cools down this light will go OFF and
the over temperature condition will automatically reset. Note that the mains power switch should remain
in the on position such that the fan continues to operate thus allowing the unit to cool sufficiently. Do not
switch the unit off should a thermal overload condition be present.
The display will also show error code E-- in the event of an over current or over temperature.
A-11665
12. Shielding Gas Inlet
The Shielding Gas Inlet connection is used to supply the appropriate shielding gas to the unit. Refer to
section 4.03 for GTAW (TIG) set up details.
!
WARNING
Only Inert Shielding Gases specifically designed for welding applications should be used.
13. On / Off Switch
This switch is used to turn the unit on/off.
14. Fan on Demand
The Transtig 170Pi is fitted with a fan on demand feature. Fan on demand automatically switches the cooling
fan off when it is not required. This has two main advantages; (1) to minimize power consumption, and
(2) to minimize the amount of contaminants such as dust that are drawn into the power source.
Note that the fan will only operate when required for cooling purposes and will automatically switch off when
not required.
Summary of Contents for 170Oi
Page 6: ......
Page 16: ...TRANSTIG 170Pi GENERAL INFORMATION 1 10 Manual 0 5242 Notes ...
Page 20: ...TRANSTIG 170Pi INTRODUCTION 2 4 Manual 0 5242 Notes ...
Page 26: ...TRANSTIG 170Pi INSTALLATION 3 6 Manual 0 5242 Notes ...
Page 44: ...TRANSTIG 170Pi OPERATION 4 18 Manual 0 5242 Notes ...
Page 46: ...TRANSTIG 170Pi INTRODUCTION 5 2 Manual 0 5242 Notes ...
Page 66: ...TRANSTIG 170Pi TROUBLESHOOTING 6 20 Manual 0 5242 Notes ...
Page 80: ...TRANSTIG 170Pi ASSEMBLY PROCEDURE 8 6 Manual 0 5242 Notes ...
Page 84: ...TRANSTIG 170Pi KEY SPARE PARTS 9 4 Manual 0 5242 Notes ...