TRANSTIG 170Pi
Manual 0-5242
4-3
OPERATION
A-11647
Figure 4-3: Programming Mode
STICK Programming Mode
Programming Parameter
Control Panel Display
hot Start
This parameter operates in
STICK mode to improve the start
characteristics for stick electrodes
HOT START current is on top of the
BASE current.
e.g. HOT START current = 130 amps
when BASE (WELD) = 100 amps &
HOT START = 30 amps
Range is 0 to 70A. Factory default
is 20A. Note that maximum weld
current is 170A.
Base Current
This parameter sets the STICK weld
current.
Range is 5 to 170A. Factory default
is 120A.
Summary of Contents for 170Oi
Page 6: ......
Page 16: ...TRANSTIG 170Pi GENERAL INFORMATION 1 10 Manual 0 5242 Notes ...
Page 20: ...TRANSTIG 170Pi INTRODUCTION 2 4 Manual 0 5242 Notes ...
Page 26: ...TRANSTIG 170Pi INSTALLATION 3 6 Manual 0 5242 Notes ...
Page 44: ...TRANSTIG 170Pi OPERATION 4 18 Manual 0 5242 Notes ...
Page 46: ...TRANSTIG 170Pi INTRODUCTION 5 2 Manual 0 5242 Notes ...
Page 66: ...TRANSTIG 170Pi TROUBLESHOOTING 6 20 Manual 0 5242 Notes ...
Page 80: ...TRANSTIG 170Pi ASSEMBLY PROCEDURE 8 6 Manual 0 5242 Notes ...
Page 84: ...TRANSTIG 170Pi KEY SPARE PARTS 9 4 Manual 0 5242 Notes ...