TRANSTIG 170Pi
OPERATION 4-4
Manual 0-5242
Programming Parameter
Control Panel Display
Arc Force
Arc Force is effective when in
STICK mode only. Arc Force control
provides an adjustable amount of
Arc Force (or "dig") control. This
feature can be particularly beneficial
in providing the operator the ability
to compensate for variability in
joint fit-up in certain situations with
particular electrodes. In general
increasing the Arc Force control
toward 100% (maximum Arc Force)
allows greater penetration control to
be achieved.
Range is 0 to 100%. Factory default
is 30%.
LIFT TIG and hF TIG Programming Mode
Programming Parameter
Control Panel Display
Pre Flow
This parameter operates in 2T and
4T HF TIG mode only and is used to
provide gas to the weld zone prior
to striking the arc, once the torch
trigger switch has been pressed.
This control is used to dramatically
reduce weld porosity at the start of
a weld.
Range is 0.0 to 5.0 seconds.
Factory default is 0.1 second.
Initial Current
This parameter operates in TIG
modes only and is used to set the
start current for TIG. In 4T mode
the Initial Current remains on until
the torch trigger switch is released
after it has been depressed. In 2T
mode this is the Initial Current for
the Up Slope current ramp.
Range is 5 to 170A. Factory default
is 30A.
Summary of Contents for 170Oi
Page 6: ......
Page 16: ...TRANSTIG 170Pi GENERAL INFORMATION 1 10 Manual 0 5242 Notes ...
Page 20: ...TRANSTIG 170Pi INTRODUCTION 2 4 Manual 0 5242 Notes ...
Page 26: ...TRANSTIG 170Pi INSTALLATION 3 6 Manual 0 5242 Notes ...
Page 44: ...TRANSTIG 170Pi OPERATION 4 18 Manual 0 5242 Notes ...
Page 46: ...TRANSTIG 170Pi INTRODUCTION 5 2 Manual 0 5242 Notes ...
Page 66: ...TRANSTIG 170Pi TROUBLESHOOTING 6 20 Manual 0 5242 Notes ...
Page 80: ...TRANSTIG 170Pi ASSEMBLY PROCEDURE 8 6 Manual 0 5242 Notes ...
Page 84: ...TRANSTIG 170Pi KEY SPARE PARTS 9 4 Manual 0 5242 Notes ...