TRANSTIG 170Pi
Manual 0-5242
3-3 INSTALLATION
NOTE 4
Minimum Generator Recommendation at the Maximum Output Duty Cycle.
Due to large variations in performance and specifications of different brands and types of generators,
Cigweld cannot guarantee full welding output power or duty cycle on every brand or type of generator.
Some small generators incorporate low cost circuit breakers on their outputs. These circuit breakers
usually will have a small reset button, and will trip much faster than a switchboard type circuit
breaker. This may result in not being able to achieve full output or duty cycle from the power source
/ generator combination. For this reason we recommend a generator that incorporates switchboard
type circuit breakers.
Cigweld recommends that when selecting a generator, that the particular power source / generator
combination be adequately trialled to ensure the combination performs to the users expectations.
NOTE 5
CIGWELD reserves the right to change product performance and specifications without notice.
3.03 Environment
These units are designed for use in environments with
increased hazard of electric shock as outlined in AS
60974.1 and AS 1674.2.
A. Examples of environments with increased hazard
of electric shock are:
1. In locations in which freedom of movement
is restricted, so that the operator is forced
to perform the work in a cramped (kneeling,
sitting or lying) position with physical contact
with conductive parts.
2. In locations which are fully or partially limited
by conductive elements, and in which there
is a high risk of unavoidable or accidental
contact by the operator.
3. In wet or damp hot locations where humidity
or perspiration considerable reduces the
skin resistance of the human body and the
insulation properties of accessories.
B. Environments with increased hazard of electric
shock do not include places where electrically
conductive parts have been insulated.
3.04 Location
Be sure to locate the welder according to the following
guidelines:
A. In areas, free from moisture and dust.
B. Ambient temperature between 0° C to 40° C.
C. In areas, free from oil, steam and corrosive gases.
D. In areas, not subjected to abnormal vibration or
shock.
E. In areas, not exposed to direct sunlight or rain.
F. Place at a distance of 300mm or more from walls
or similar that could restrict natural air flow for
cooling.
G. The enclosure design of this power source meets
the requirements of IP23S as outlined in AS60529.
This provides adequate protection against solid
objects (greater than 12mm), and direct protection
from vertical drops. Under no circumstances
should the unit be operated or connected in a
micro environment that will exceed the stated
conditions. For further information please refer
to AS 60529.
H. Precautions must be taken against the power
source toppling over. The power source must
be located on a suitable horizontal surface in the
upright position when in use.
Summary of Contents for 170Oi
Page 6: ......
Page 16: ...TRANSTIG 170Pi GENERAL INFORMATION 1 10 Manual 0 5242 Notes ...
Page 20: ...TRANSTIG 170Pi INTRODUCTION 2 4 Manual 0 5242 Notes ...
Page 26: ...TRANSTIG 170Pi INSTALLATION 3 6 Manual 0 5242 Notes ...
Page 44: ...TRANSTIG 170Pi OPERATION 4 18 Manual 0 5242 Notes ...
Page 46: ...TRANSTIG 170Pi INTRODUCTION 5 2 Manual 0 5242 Notes ...
Page 66: ...TRANSTIG 170Pi TROUBLESHOOTING 6 20 Manual 0 5242 Notes ...
Page 80: ...TRANSTIG 170Pi ASSEMBLY PROCEDURE 8 6 Manual 0 5242 Notes ...
Page 84: ...TRANSTIG 170Pi KEY SPARE PARTS 9 4 Manual 0 5242 Notes ...