EN - 1
CONTENTS
PAGE
1 IMPORTANT RECOMMENDATIONS
3
1.1 Electrical power supply
3
1.2 Specifications of the X
TRACONNECT
2
board
3
1.3 Warning
3
1.4 Earthing
3
1.5 Connection of sensors
3
1.6 Connection of the communication buses and of the remote console
3
1.7 Connection of the on/off inputs
3
2 GENERAL
3
2.1 Description
4
2.2 Description of the motherboard
5
2.3 Description of expansion board 3 (ADD3) on a 2-circuit machine and with the rotary switch set to '1'
0
1
2
3
4 5 6
7
8
6
2.4 Description of expansion board 3 (ADD3) on a 3-circuit machine. Module 2, rotary switch set to '2'
01
2
3
4 5 6
7
8
7
2.5 Description of expansion board 1 on a 3-circuit machine. Module 2, rotary switch set to '3'
0 1
2
3
4 5 6 7
8
8
2.6 Connection via RS485 serial port for BMS or control console and Multiconnect with 500 kW module
9
2.7 RELAY BOARD
10
3 ACCESS LEVELS
10
3.1 Selecting an authorised access level
10
3.2 Accessing the various access levels
10
3.3 Configuring access levels on the controller
11
3.4 Management of the numeric codes for accessing levels 2 and 3
12
3.5 Classification of the menus and their functions
12
4 LIST OF PARAMETERS
12
5 CONTENTS OF THE MENUS
19
5.1 Main menu
19
5.2 Setpoint menu
19
5.3 Unit status menu
19
5.4 Measured values menu
20
5.5 Unit parameters menu
21
5.6 Adjustment parameters menu
21
5.7 Reading parameters menu
22
5.8 Fault memory menu
23
5.9 Test mode menu
24
5.10 TIME SCHEDULES menu
25
5.11 COMMUNICATION Menu
25
5.12 MASTER/SLAVE menu
26
5.13 AERO-CONNECT menu
26
5.14 ACCESS LEVEL SELECTION menu
26
6 MANAGEMENT OF THE ON/OFF INPUTS
26
6.1 Automatic machine operation control
26
6.2 Automatic water pump control
26
6.3 Load shedding control
27
6.4 Water flow switch
27
6.5 Phase controller fault
28
6.6 Pump 6 fault
28
6.7 Emergency stop (split system unit and dry cooler.
28
6.8 Fan fault (circuits 1, 2 and 3)
29
6.9 External fault
29
6.10 Compressor 1, 2 or 3 protection ("SE" box)
29
6.11 Discharge fault on circuit 1, 2 or 3
29
6.12 High-pressure switch fault on circuit 1, 2 or 3
30
6.13 LP fault on circuit 1, 2 or 3
30
6.14 Minimum desuperheat discharge fault
31
6.15 Electronic expansion valve fault
31
6.16 Lubrication fault
31
6.17 Minimum and maximum superheat fault
32
7 MANAGEMENT OF THE ANALOGUE INPUTS
33
8 PRESSURE SENSOR
34
9 PUMP MANAGEMENT
35
10. EVAPORATOR WINTER AND FROST PROTECTION
35
11. MANAGEMENT OF THE OUTPUTS OF LIQUID VALVES 1, 2 AND 3
36
12. MANAGEMENT OF THE ECONOMISER VALVES (HPS)
36
13. MANAGEMENT OF THE 25% OUTPUT COMPRESSOR VALVES
37
14 MANAGEMENT OF THE LIQUID INJECTION VALVES
37
15. MANAGEMENT OF THE FUNCTIONS
37
15.1 Compressor starting order (3 circuits) and runtime balancing
37
15.2 Short-cycle protection and minimum off-time
37