Options
Description
Advantages
LD
ILD
HP evap. variable-speed
single-pump
Evaporator hydraulic module equipped with
a high pressure variable-speed pump, drain
valve, air vent and pressure sensors.
For more details, refer to the dedicated
section (expansion tank not included; option
with built-in hydraulic safety components
available.)
Quick and easy installation (plug & play),
significant reduction in pumping energy
consumption level (more than two-thirds),
precise water flow control, improved system
reliability
●
●
Variable-speed dual
high-pressure pump
Dual high-pressure water pump with speed
regulator, pressure sensors. Multiple water
flow rate control options. For more details,
refer to the dedicated chapter.
Quick and easy installation (plug & play),
significant reduction in pumping energy
consumption level (more than two-thirds),
precise water flow control, improved system
reliability
●
●
High nominal energy
efficiency
Higher air flow through the condenser coils
improving heat exchange efficiency on the
condenser
Energy cost reduction and extended
operating envelope (full load operation at
higher air temperature)
●
●
High seasonal energy
efficiency (VSD)
Unit equipped with variable-speed fans
(VSD)
Enhances the unit seasonal energy efficiency
performance and reduces the noise emission
thanks to a smooth fan speed variation.
0602R-1400R
●
High seasonal energy
efficiency (EC)
Variable-speed fans with EC motors
Enhances the unit seasonal energy efficiency
performance and reduces the noise emission
thanks to a smooth fan speed variation.
●
●
High energy efficiency
underfloor heating/cooling
system application
Optimisation of the refrigerant circuit for the
underfloor heating/cooling system application
Improvement of performances and reduction
of energy costs for the underfloor heating/
cooling system application
No
●
Lon gateway
Two-directional communication board
complying with Lon Talk protocol
Connects the unit by communication bus to a
building management system
●
●
Bacnet over IP
Two-directional high-speed communication
using BACnet protocol over Ethernet
network (IP)
Easy and high-speed connection by Ethernet
line to a BMS. Allows access to multiple unit
parameters
●
●
Energy management
module
EMM control board with additional inputs/
outputs. See Energy Management Module
section
Extended remote control capabilities (setpoint
reset, ice storage end, demand limits, boiler
on/off command...)
●
●
Contact for refrigerant
leak detection
0-10 V signal to report any refrigerant
leakage in the unit directly (the leak detector
itself must be supplied by the customer)
Immediate customer notification of refrigerant
losses to the atmosphere, allowing timely
corrective actions
●
●
Compliance with Swiss
regulations
Additional tests on the water type heat
exchangers: supply of supplementary test
certifications and certificates (supplementary
documents linked to the Pressure Equipment
Directive)
Compliance with Swiss regulations
●
●
Compliance with
Russian regulations
EAC certification
Compliance with Russian regulations
●
●
Compliance with
Australian regulations
Unit approved to Australian code
Compliance with Australian regulations
●
●
Coil defrost resistance
heaters
Electric heaters under the coils and the
condensate pans
Prevents frost formation on the coils;
compulsory in heating mode if the outdoor
temperature is below 0°C
No
●
Insulation of the
evaporator inlet/outlet
refrigerant lines
Thermal insulation of the evaporator
inlet/outlet refrigerant lines, with flexible
and UV-resistant insulation
Prevents condensation on the evaporator
inlet/outlet refrigerant lines
●
●
MCHE anti-corrosion
protection Protect2
Coating applied using a conversion process
which modifies the surface of the aluminium
producing a coating that is integral to the
coil. Complete immersion in a bath to
ensure 100% coverage. No heat transfer
variation, tested to withstand more than
4000 hours of salt spray as per ASTM B117
Protect2 Improved corrosion resistance of the
MCHE coils by 2, recommended for use in
moderately corrosive environments
●
No
MCHE anti-corrosion
protection Protect4
Extremely durable and flexible epoxy
polymer coating applied on micro channel
coils by electro coating process, final UV
protective topcoat. Minimal heat transfer
variation, tested to withstand 6000 hours
of constant neutral salt spray as per
ASTM B117, improved impact resistance
as per ASTM D2794
Protect4 Improved corrosion resistance of the
MCHE coils by 4, recommended for use in
corrosive environments
●
No
Flanged evaporator
water connection kit
Victaulic piping connections with flanged
joints
Easy installation
●
●
Compressor enclosure
Compressor enclosure
Improved aesthetics, compressor protection
against external elements (dust, sand,
water…)
●
●
230 V electrical plug
230 VAC power source provided with plug
socket and transformer (180 VA, 0.8 A)
Enables connection of a laptop or an
electrical device during system start-up or
maintenance
●
●
Expansion tank
6-bar expansion tank integrated in the
hydraulic module (requires hydraulic module
option)
Easy and fast installation (plug & play),
and protection of closed water systems from
excessive pressure
●
●
12 - OPTIONS
EN-53
AQUACIAT
POWER
™ LD/ILD