ZRMV
高压固态软起动装置说明书
User’s Manual for ZRMV High Voltage Solid Soft Starter
29
F15
也将进行欠载保护。同时软起动也时时检测三相电流,当三相电流超出了
F12
所设定的不平衡度时,也
将进行相电流不平衡保护;保护的同时将会在界面上显示相应的故障类型,便于用户查找。
Users can set F00, the rated current of motor, according to the power of the motor, so as to make the soft
starter fit in well with the motor and protect the motor perfectly. The soft starter will carry out the over-current
protection when the current exceeds the over-current protection value set by means of the parameter F13 in the
process of running. If the electronic heat overload class and tripping time set by means of the parameter F11 are
exceeded, the soft starter will carry out overload protection. The soft starter can also perform underload protection
according to the parameter F14 and F15. In addition, the soft starter can inspect three-phase current at all times, and
perform phase current imbalance protection when the three-phase current exceeds the imbalance degree set by
means of F12. It will display the type of the fault in the interface while providing protection, which can facilitate the
search of users.
5.5.5
高级参数项
高级参数项
高级参数项
高级参数项
(Senior Parameters)
参数
参数
参数
参数
Parameter
名称
名称
名称
名称
Item
范围
范围
范围
范围
Range
出厂值
出厂值
出厂值
出厂值
Value
P00
显示选择
Display options
0-
电机额定电流
1-
平均电流
2-R
相电流
3-S
相电流
4-T
相电流
5-
模拟口值
%
6-
输出电压
%
7-
起动倒计时时间
8-
刹车倒计时时间
0-rate current of motor 1-average current 2-R current
3-S current 4-T current 5-analogue input (%)
6-output voltage (%) 7-start countdown 8-brake countdown
1
P01
Run/stop
控制方式
Control mode of run/stop
0-
键盘运行禁止
/485
通讯控制禁止
1-
键盘运行允许
/485
通讯控制禁止
2-
键盘运行禁止
/485
通讯控制允许
3-
键盘运行允许
/485
通讯控制允许
4-
键盘点动允许
/485
通讯控制禁止
1