9
4
4.. IIn
nsstta
alllla
attiio
on
n P
Prre
ecca
au
uttiio
on
nss
Do not install the product at the following places.
•
Near fire
•
Near flammable material
•
Wet place
•
A place exposed to rain and snow
•
A place exposed to direct sunlight
•
Near chemicals(volatile material, organic solvent, etc.)
•
Dark place
•
A place below 32
O
F(0
O
C) or a place with the possibility of dropping below 32
O
F(0
O
C).
※
When the product is installed in a dark place while the power saving function is
selected, hot water may not operate even during daytime due to lack of light.
(Please install it in a brighter location.)
1
When transporting the product, do not tilt it over 45
°
.
※
Severe tilting can cause reduced performance.
2
Install the product at a place where the surface is flat, and after installation,
always adjust the level of the product using a level gauge.
※
Tilting of the product can reduce water purification performance and ice making
capability.
3
Leave approximately 8 in(20cm). between the wall, sides and rear surfaces of the prod-
uct so that ventilation may be smoothly performed for safe operation.
※
This can be cause reduced performance.
4
Do not install any heat radiating products near rear of the product.
5
Use the following water quality range.
•
Water pressure : 7~120psi(0.5~8.4kgf/cm
2
)
•
Water temperature : 39~100
O
F(4~38
O
C)
•
pH : 5~10
•
Hardness : 300ppm or less
•
Evaporated remains : 500ppm or less
•
Water quality : Biologically safe water quality
※
When using another water quality than the above, discuss with our company.
※
If you do not use water quality within the above range without prior discussion
with our company, the product can be excluded from the stated warranty period.
6
Do not connect hot water over 100
O
F(38
O
C) to this product.
※
This can be the cause of trouble and decline in ice making performance.
7
Summary of Contents for Iguassu ICE 500