background image

Precautions 

To prevent harm to users or other people during usage of the product and 
to extend the lifespan of the product, please follow the precautions below:

General Instruction

The wireless accessories should be connected to the control panel before use.

Low power voltage would affect transmitting distance range.

2 cells of 3.7V/800mAh battery backup or standard power adapter for power supply.

All accessories from our company are compatible with this control panel.

Do not press SOS key if there is no emergency to avoid disturbing neighborhood.

Check the system regularly to ensure the system works properly in case of emergency.

The control panel is neither waterproof nor moisture-proof, please install it in a shady, 
cool and dry place. 

The case of the control panel is made of ABS. Please keep it away from strong light 
for a longer lifespan. 

Forbiddance

The control panel is non explosion-proof. Please keep it away from fire, flame sources. 

Install the control panel away from objects such as heater,  air conditioner,  microwave 
oven etc. that produces heat or electric-magnetic.

Forbiddance of Decomposition

Take the control panel for disposal of recycling according to the local regulation. 

Disassembly for this product can not be done by non-professionals.

FAQ 

Phenomena  

Cause of Malfunction 

Troubleshoot Method

No response from 
control panel 
operation

Accessories cannot 
connect to control 
panel

No response from 
the control panel 
by operating 
remote control 

RFID card/tag fail 
to disarm

Touch keyboard fail 
to make related 
setting

Power switch is off

A/C Power failure

Lithium battery backup 
power exhausted 

Panel not in learning 
status

Accessories not triggered 
for learning

When learning, 2 beeps 
are heard from panel

Remote control is not 
learned to control panel

Out of range between 
remote control and panel

RFID car/tag not connected 
to the panel

Not logged onto the 
setting menu. 

Open battery compartment, 
turn on the power

Contact local main power 
supply bureau 

Connect to main power with 
adapter

Make sure the panel set in 
learning status

Make sure the triggered 
accessories transmitting signal 
to panel for learning 

This means accessory has 
been coded already

Follow the manual and connect 
the remote control to panel

No more than 80 meters in 
open area
(no interference)

Signal repeater could be added

Follow the work manual and 
code RFID card/tag to the panel

Input the correct admin code,
press 

 and log on menu 

[ Enter ]

setting

32

31

Summary of Contents for CG-A11

Page 1: ...A11 Security Alarm System Printed in China PA A11 UM EN V1 0 2014 Chuango All rights reserved...

Page 2: ...te controls 50 wireless sensors and 50 RFID tags Store 6 alarm phone numbers and 2 ADEMCO CID CMS numbers 10 seconds voice memo and alarm voice message recordable Disarm the system by RFID tags and un...

Page 3: ...Delay Backlight Time Timed Arm Disarm Edit Greeting Message Remote Phone Control Linecut Alarm 7 9 10 11 13 14 28 Connect to Electronic Lock Connect to CMS Center Add CMS Phone Number Delete CMS Phon...

Page 4: ...ower CG A11 Control Panel x1 Pet Immune PIR Motion Detector x 1 Wireless Remote Control x 2 The remote control is compact and portable it is convenient to carry it to arm disarm part arm the alarm sys...

Page 5: ...Down Enter SOS Clear Call Front Side Control Panel Layout Buzzer Tamper Switch Speaker Backup Batteries AC Adapter Interface Power ON OFF PSTN Land Line Interface Interfaces for Wired Sensors MIC Out...

Page 6: ...ers Please make sure the panel has been connected to PSTN land line to ensure safety 1 2 Connect the smaller connector of provided telephone cable to the PSTN land line interface at the back side of t...

Page 7: ...control panel the system enters Home Mode Home Mode when one beep is heard and the Home Mode LED Indicator lights on All the Normal Sensors are armed except the Home Mode Sensors which are disarmed s...

Page 8: ...ialing or press Esc Call button to end a conversation 4 Voice Memo Press the button to record 10 seconds voice Record Voice Memo message The Play Voice Memo circle will be flashing in blue to remind y...

Page 9: ...01 50 Edit Sensor Type Normal Sensor 24 Hour Sensor Delay Sensor Home Sensor Edit Sensor Name Phone Numbers System Settings Date And Time Entry Exit Delay Backlight Time 20S Auto Arm Disarm Edit Welc...

Page 10: ...r 1 2 3 4 Add Alarm Phone Number Note If user want to check or edit the stored phone number enter Alarm Number1 6 to check and edit Delete Alarm Phone Number Note If user wants to set CMS center phone...

Page 11: ...choose Edit press Enter Press or choose Sensor 01 50 press Enter Press or choose Edit Sensor Type press Enter Press or choose one type of Normal Sensor 24 Hour Sensor Delay Sensor Home Sensor press E...

Page 12: ...D display will collect the triggering time of the sensors Then you can count the connected sensors based on the numbers displayed on the LCD screen Exit by pressing Esc button 3 System Settings 3 1 Da...

Page 13: ...delay is set to leave time for user to disarm the system before the sensors send signal to control panel after triggering after the set time User can set timed arm and disarm according to daily sched...

Page 14: ...low 1 2 3 4 Note Alarm system will hang up after 30 seconds with no operation Remote Phone Control Instruction Table When linecut alarm function is on the control panel will alarm once the PSTN land l...

Page 15: ...he panel will silently dial alarm telephone numbers stored 1 2 3 4 Log on the menu press or choose System Settings press Enter Press or choose Access Code press Enter Press or choose Duress Code press...

Page 16: ...ion Turn on off wireless siren Log on the menu press or choose System Settings press Enter Press or choose Siren Setup press Enter Press or choose Wireless Siren press Enter Press or choose Siren On O...

Page 17: ...ng Time Set Ringing Time for All Sirens Press or choose Siren Setup press Enter Press or choose Siren Alert Time press Enter Input the ringing time press Enter Siren ringing time is calculated as seco...

Page 18: ...nter Press or choose Del Phone Number press Enter Press or choose in order CMS Number1 2 press Enter Delete stored CMS phone no Press Enter User ID 1 2 3 Log on the menu press or choose System Setting...

Page 19: ...ol panel for disposal of recycling according to the local regulation Disassembly for this product can not be done by non professionals FAQ Phenomena Cause of Malfunction Troubleshoot Method No respons...

Page 20: ...ensors 50 pcs Maximum RFID Tags 50 pcs Maximum Event Logs 150 events Housing Material ABS plastic Operation Condition Temperature 10 C 55 C Relative Humidity 80 non condensing Dimension L x W x H 185x...

Page 21: ...n one beep is heard and the Home Mode LED Indicator lights on All the Normal Sensors are armed except the Home Mode Sensors which are disarmed so that users can move freely at home Mute Mode When arm...

Page 22: ...magnet mounted near the sensor is moved away External input for wired accessory is available at the N C interface The tamper protection ensures that sabotage attempts to move the contact will result i...

Page 23: ...smitter and magnet with double sided tapes or screws Avoid mounting sensors in areas with a large quantity of metal or electrical wiring such as a furnace or utility room 40 39 Specifications Power su...

Page 24: ...res pet immunity for small animals up to 25kgs Appearance 1 Detection window 2 LED indicator 3 Snap joint 4 Test button 5 Bracket 1 2 Infrared sensor It detects the infrared rays released by human bod...

Page 25: ...will switch to the sleeping state to save power At this time the LED will not blink even human movement is detected and no alarm After no movement within the next 3 minutes the detector switches back...

Page 26: ...ted the LED blinks once Side view Top view Adjust the angle Adjust the bracket angle to achieve the best detection effect Note If pet immune function is applied please do not adjust the angle up or do...

Page 27: ...Strong light interferes with detection sensitivity In addition complicated situations such as traffic flow stream of people also should be avoided Mount the detector in a proper angle The installatio...

Page 28: ...n Scope 8m 110 Pet Immunity 25kg Transmitting Distance 80m in open area Radio Frequency 433 92MHz 75KHz Housing Material ABS plastic Operation Condition Temperature 10 C 55 C Relative Humidity 80 non...

Reviews: