Normal Sensor: 

In armed mode, when normal sensors are triggered, 

alarm system will alarm. In disarmed mode, when normal sensors are 
triggered, alarm system will not alarm. 

24 Hour Sensor: 

Under any circumstances, when 24 Hour Sensors are 

triggered, alarm system will alarm at once.

Delay Sensor: 

If user wants to use the entry and exit delay, related sensors 

need to be set in entry and exit delay zone. When setting is done, after set 
delay time, those sensors will make system alarm. Refer to Entry and 
Delay Setup for details.

Home Sensor: 

In home mode, only normal sensors will be triggered for 

alarming while home sensors will not be triggered. This will allow user to 
move freely at home.

If user wants to rename the sensors, please choose “Edit Sensor Name” in 
the step    and press

. Then input the sensor name. 

 [Enter]

Names of Sensors

5

Test Mode

Test if the sensors are connected successfully to the control panel.

Log on the menu, press

or

, choose “Accessories”, press

.

 [    ]   [    ] 

 [Enter]

Press

or

, choose “Test Mode”, press

. LCD display will 

 [    ]   [    ] 

 [Enter]

show “Yes?”, Press

 again to start testing mode for 10 minutes.

 [Enter]

Please trigger coded sensors in order, the sensors will transmit signals to 
control panel. When 3 beeps are heard, LCD display will collect the 
triggering time of the sensors. Then you can count the connected sensors 
based on the numbers displayed on the LCD screen. Exit by pressing

 [Esc] 

button.

3. System Settings

3.1 Date and Time

Press

or

, choose “Date and Time”, press

.

 [    ]   [    ] 

 [Enter]

Press

or

, choose “Date”, press

.

 [    ]   [    ] 

 [Enter]

Input date, press 

[Enter].

1

2

Log on the menu, press

or

, choose “System Settings”, press

.

 [    ]   [    ] 

 [Enter]

Date Format

Press

or

, choose “Date and Time”, press

.

 [    ]   [    ] 

 [Enter]

Press

or

, choose “Date Format”, press

.

 [    ]   [    ] 

 [Enter]

Press

or

, choose format, press

.

 [    ]   [    ] 

 [Enter]

1

2

Log on the menu, press

or

, choose “System Settings”, press 

.

 [    ]   [    ] 

[Enter]

Time 

The default time is on 24 hours standard.

Press

or

, choose “Date and Time”, press

.

 [    ]   [    ] 

 [Enter]

Press

or

, choose “Time”, press

.

 [    ]   [    ] 

 [Enter]

Input 

, press 

.

current time  

[Enter]

1

2

Log on the menu, press

or

, choose “System Settings”,  press

.

 [    ]   [    ] 

 [Enter]

Date

I

f user is not used to taking along with the remote control, entry and exit 

delay could be set in the system. Following is the operation instruction for 
arming and disarming. 
When entry and exit delay is set, user could exit the house in set time 
period, then system will be armed automatically; when user is back 
without disarming the system, entry delay will allow time for user to 
disarm the system. Otherwise, the system will treat this as an intrusion and 
it will be triggered and send out alarming alert. 

Note!

The entry and exit delay is only for delay sensors.

18

17

3

4

3

4

3

4

3.2 Entry and Exit Delay 

Summary of Contents for CG-A11

Page 1: ...A11 Security Alarm System Printed in China PA A11 UM EN V1 0 2014 Chuango All rights reserved...

Page 2: ...te controls 50 wireless sensors and 50 RFID tags Store 6 alarm phone numbers and 2 ADEMCO CID CMS numbers 10 seconds voice memo and alarm voice message recordable Disarm the system by RFID tags and un...

Page 3: ...Delay Backlight Time Timed Arm Disarm Edit Greeting Message Remote Phone Control Linecut Alarm 7 9 10 11 13 14 28 Connect to Electronic Lock Connect to CMS Center Add CMS Phone Number Delete CMS Phon...

Page 4: ...ower CG A11 Control Panel x1 Pet Immune PIR Motion Detector x 1 Wireless Remote Control x 2 The remote control is compact and portable it is convenient to carry it to arm disarm part arm the alarm sys...

Page 5: ...Down Enter SOS Clear Call Front Side Control Panel Layout Buzzer Tamper Switch Speaker Backup Batteries AC Adapter Interface Power ON OFF PSTN Land Line Interface Interfaces for Wired Sensors MIC Out...

Page 6: ...ers Please make sure the panel has been connected to PSTN land line to ensure safety 1 2 Connect the smaller connector of provided telephone cable to the PSTN land line interface at the back side of t...

Page 7: ...control panel the system enters Home Mode Home Mode when one beep is heard and the Home Mode LED Indicator lights on All the Normal Sensors are armed except the Home Mode Sensors which are disarmed s...

Page 8: ...ialing or press Esc Call button to end a conversation 4 Voice Memo Press the button to record 10 seconds voice Record Voice Memo message The Play Voice Memo circle will be flashing in blue to remind y...

Page 9: ...01 50 Edit Sensor Type Normal Sensor 24 Hour Sensor Delay Sensor Home Sensor Edit Sensor Name Phone Numbers System Settings Date And Time Entry Exit Delay Backlight Time 20S Auto Arm Disarm Edit Welc...

Page 10: ...r 1 2 3 4 Add Alarm Phone Number Note If user want to check or edit the stored phone number enter Alarm Number1 6 to check and edit Delete Alarm Phone Number Note If user wants to set CMS center phone...

Page 11: ...choose Edit press Enter Press or choose Sensor 01 50 press Enter Press or choose Edit Sensor Type press Enter Press or choose one type of Normal Sensor 24 Hour Sensor Delay Sensor Home Sensor press E...

Page 12: ...D display will collect the triggering time of the sensors Then you can count the connected sensors based on the numbers displayed on the LCD screen Exit by pressing Esc button 3 System Settings 3 1 Da...

Page 13: ...delay is set to leave time for user to disarm the system before the sensors send signal to control panel after triggering after the set time User can set timed arm and disarm according to daily sched...

Page 14: ...low 1 2 3 4 Note Alarm system will hang up after 30 seconds with no operation Remote Phone Control Instruction Table When linecut alarm function is on the control panel will alarm once the PSTN land l...

Page 15: ...he panel will silently dial alarm telephone numbers stored 1 2 3 4 Log on the menu press or choose System Settings press Enter Press or choose Access Code press Enter Press or choose Duress Code press...

Page 16: ...ion Turn on off wireless siren Log on the menu press or choose System Settings press Enter Press or choose Siren Setup press Enter Press or choose Wireless Siren press Enter Press or choose Siren On O...

Page 17: ...ng Time Set Ringing Time for All Sirens Press or choose Siren Setup press Enter Press or choose Siren Alert Time press Enter Input the ringing time press Enter Siren ringing time is calculated as seco...

Page 18: ...nter Press or choose Del Phone Number press Enter Press or choose in order CMS Number1 2 press Enter Delete stored CMS phone no Press Enter User ID 1 2 3 Log on the menu press or choose System Setting...

Page 19: ...ol panel for disposal of recycling according to the local regulation Disassembly for this product can not be done by non professionals FAQ Phenomena Cause of Malfunction Troubleshoot Method No respons...

Page 20: ...ensors 50 pcs Maximum RFID Tags 50 pcs Maximum Event Logs 150 events Housing Material ABS plastic Operation Condition Temperature 10 C 55 C Relative Humidity 80 non condensing Dimension L x W x H 185x...

Page 21: ...n one beep is heard and the Home Mode LED Indicator lights on All the Normal Sensors are armed except the Home Mode Sensors which are disarmed so that users can move freely at home Mute Mode When arm...

Page 22: ...magnet mounted near the sensor is moved away External input for wired accessory is available at the N C interface The tamper protection ensures that sabotage attempts to move the contact will result i...

Page 23: ...smitter and magnet with double sided tapes or screws Avoid mounting sensors in areas with a large quantity of metal or electrical wiring such as a furnace or utility room 40 39 Specifications Power su...

Page 24: ...res pet immunity for small animals up to 25kgs Appearance 1 Detection window 2 LED indicator 3 Snap joint 4 Test button 5 Bracket 1 2 Infrared sensor It detects the infrared rays released by human bod...

Page 25: ...will switch to the sleeping state to save power At this time the LED will not blink even human movement is detected and no alarm After no movement within the next 3 minutes the detector switches back...

Page 26: ...ted the LED blinks once Side view Top view Adjust the angle Adjust the bracket angle to achieve the best detection effect Note If pet immune function is applied please do not adjust the angle up or do...

Page 27: ...Strong light interferes with detection sensitivity In addition complicated situations such as traffic flow stream of people also should be avoided Mount the detector in a proper angle The installatio...

Page 28: ...n Scope 8m 110 Pet Immunity 25kg Transmitting Distance 80m in open area Radio Frequency 433 92MHz 75KHz Housing Material ABS plastic Operation Condition Temperature 10 C 55 C Relative Humidity 80 non...

Reviews: