background image

 

12 

RPMX-100U Installation Manual

 

 

 

 

Figure 10. 

 

  

Step 7 ñ Adjust Image Geometry 

The projection head module is mounted to a uniquely designed 6-axis adjustment 
mechanism that is used during the setup process to fine-tune the geometry of the 
image. It does this by moving the module about the X, Y and Z-axes in varying 
degrees. How closely the image appears to match between screens is determined by 
the quality of adjustments made during this step in the setup process. 

To begin adjusting a wall

it is recommended that you begin with an end unit on the 

bottom row then adjust the units adjacent to it. Once these are closely matched, then 
move to the next unit and continue the process. Work your way across and up until 
all units have been adjusted. Once you have completed adjusting the entire wall lock 
the adjustments in place by tightening the four lock screws – refer to Figure 11. for 
location – and the smaller set screws on the collar of each adjustment screw before 
moving on to the next step. 

 Do not over-adjust the screws on the adjuster. If you are finding it difficult 

to adjust the adjuster, it is probably because you have reached the end of the 
adjustment range. In this case, it is recommended that you return the adjuster 
back to the nominal position and begin adjustment again. 

TIP: It is recommended that you take note of the position of the screws on the side 

of the adjuster before you begin adjusting. By taking notice of where these screws are 
located, you can quickly and easily return the adjuster back to its original position, if 
required.  

 

 

How to adjust the 6-axis adjuster mechanism: 

TIP: Refer to Figure 12. when adjusting. This 

illustration identifies how to adjust the mechanism to 
correct the most common geometric adjustments 
required during setup for both possible projector 
configurations. 

1.  Unlock the adjuster, by loosening the four main 

lock screws (see Figure 11.) and the set screw 
located on the collar of each adjustment screw.  

2.  Center the image on the screen, by adjusting 

vertical and/or horizontal position. 

 

Figure 11. Adjuster 

Lock Screws (4) 

Summary of Contents for Graph-X-Master RPMX-100U

Page 1: ...search the information in this manual is subject to change without notice legacy 54 017201 02P Overview 1 Components Shipped 1 Installation and Setup Process 2 Pre Installation Considerations 2 Instal...

Page 2: ...you have received all components before you begin assembly 4 6 32 x 3 8 hex screws projector mounting screws mounting bracket used in 90 degree configurations 4 20 x 2 hex screws for 90 degree bracke...

Page 3: ...hat type and size of screen to use Choose a screen size most appropriate for your lens and application Keep in mind if the intended use of the projector is to display text information the image size m...

Page 4: ...lighting conditions When designing a projection room consider positioning the projector and screen where maximum audience coverage and space efficiency is achieved For example placing the screen along...

Page 5: ...Remove the mounting bracket on the adjuster used for mounting the PHM assembly in a lens horizontal configuration 5 Install the mounting bracket required for lens vertical configurations on the adjust...

Page 6: ...pointing up 90 degrees Lower it back down on the adjuster aligning the mounting holes on the PHM with the new mounting bracket on the adjuster installed in Step 5 Secure the PHM in its new position us...

Page 7: ...6 RPMX 100U Installation Manual Step 3 Projector Position and Mounting Applies to RPMX 100U 38 GFX101 01 only Figure 5 Calculating Projection Distance...

Page 8: ...7 RPMX 100U Installation Manual Applies to RPMX 100U 38 GFX101 02 only Figure 6...

Page 9: ...8 RPMX 100U Installation Manual Applies to RPMX 100U 38 GFX101 05 only...

Page 10: ...eight and center of gravity 2 Allow adequate airflow around the projector if you are going to mount it in an enclosure such as a display cube Step 4 Connect Sources With the projector mounted connect...

Page 11: ...t is recommended that you wait at least 10 minutes after powering down the projector and before unplugging it from the power outlet The cooling fans in the projector DO NOT automatically turn off when...

Page 12: ...set up of the projector and is not required each time you focus 1 Power down the projector to perform this procedure Press POWER 2 Loosen the lock ring on the lens Figure 8 3 Grasp the projection len...

Page 13: ...of each adjustment screw before moving on to the next step Do not over adjust the screws on the adjuster If you are finding it difficult to adjust the adjuster it is probably because you have reached...

Page 14: ...time software setup The User s Manual describes in detail how to access and change projector software settings 1 Unless otherwise indicated instructions apply to both stand alone and multi projector...

Page 15: ...d V Position in Size and Position menu to re center the image on screen 11 Adjust Size in Size and Position menu first until the image is at the desired width then adjust Vertical Stretch Adjusting on...

Page 16: ...15 RPMX 100U Installation Manual Appendix A Technical Information RPMX 100U 38 GFX101 01 Dimensions Lens Horizontal Lens Vertical Weight Includes adjuster but not projection lens 44lbs...

Page 17: ...16 RPMX 100U Installation Manual RPMX 100U 38 GFX101 02 Dimensions Lens Horizontal Lens Vertical...

Page 18: ...17 RPMX 100U Installation Manual RPMX 100U 38 GFX101 05 Dimensions Lens Horizontal Lens Vertical...

Page 19: ...U Installation Manual Interconnections Drawing NOTE The IR PCB is located in the electronic module in RPMX 38 GFX101 01 and in the PHM in RPMX 38 GFX101 02 05 In both cases the IR PCB connects to the...