Section 4: Parts and Module Replacement
Entero RPMSP/RPMWU/RPMHD-LED01 Service Manual
4-5
020-100368-05 Rev. 1 (06-2012)
4.4.3 Light Module (LM)
Estimated Replacement Time: 5 minutes
The LM is located on the left-side of the projector
head module (PHM) assembly when facing the
lens. This assembly houses the RGB LED light
sources and contains no serviceable parts. Its
purpose is to supply light in the form of red, green
and blue, to be routed through the IRO and
processed at the DMD.
1. Tilt the PHM on its back.
2. Remove (2) slotted screws securing the
electronics module (EM) harness to the LM.
3. Remove (2) screws securing the top of the label
mounting plate to the original LM.
4. Loosen (2) screws securing the bottom of the
label mounting plate to the original LM.
5. Pull upwards on the label mounting plate to remove it from the original LM.
6. Install the label mounting plate onto the replacement LM and secure it with (4) screws (2 on the top/2 on
the bottom).