Service setups
HS Series 2K Service Manual—D13HD2-HS, D13WU2-HS, D16HD-HS, D16WU-HS, D20HD-HS, D20WU-HS
24
020-001468-02 Rev. 1 (01-2020)
Copyright ©2020 Christie Digital Systems USA Inc. All rights reserved.
Performing a PC calibration
To perform the PC calibration, complete the steps below.
1. On the IR remote keypad, press
Menu
and select
Size & Position > Size Presets > Full
Size
.
2. Enter
Service mode
.
See
3. Select
ADC Calibration
.
4. Press
Enter
.
After a few seconds, the ADC calibration status changes from
Doing
to
Done
.
Performing a video calibration
To perform the video calibration, complete the steps below.
1. On the IR remote keypad, press
Menu
and select
Size & Position > Size Presets > Full
Size
.
ID
Part name
Description
1
Test equipment
Video generator (output level: 700 mv)
2
Test signal
Timing: 800 x 600 @60Hz
3
Test pattern
16 Gray
4
Inspection item
Check if the ADC calibration status has changed from
Doing
to
Done
.
ID
Part name
Description
1
Test equipment
Video generator (output level: 700 mv)
2
Test signal
• D20HD-HS, D16HD-HS,D13HD2-HS; Analog 1920 x 1080 @60Hz
• D20WU-HS, D16WU-HS,D13WU2-HS; Analog 1920 x 1200 @60Hz
3
Test pattern
SMPTE BAR
4
Inspection items
Check if the ADC calibration status has changed from
Doing
to
Done
.