![Christie CS50-D100U User Manual Download Page 81](http://html1.mh-extra.com/html/christie/cs50-d100u/cs50-d100u_user-manual_2603506081.webp)
MAINTENANCE & TROUBLESHOOTING
4-8
RPMS, CS50 & CS70-D100U/UF
User’s Manual
3)
REMOVE LAMP
: Loosen the two screws securing the lamp in the lamp module.
Holding the lamp door open with one hand, grasp the lamp handle and pull
straight up to remove the lamp. (Figure 4.3. and Figure 4.4) The lamp
disconnects from the terminal block much like unplugging something from an
outlet.
Figure 4.3.
DO NOT touch the glass surface of the lamp. Set it aside for proper
disposal once it has cooled down.
Figure 4.4.
WARNING
Never look or stick hands inside an open lamp
compartment while the other lamp is still ON. Power is
still present in the lamp module and the heat and U.V.
light from the remaining operational lamp could cause
physical injury.