5-36
CP2230 Service Manual
020-100562-06 Rev. 1 (05-2016)
Section 5: Parts and Module Replacement
5.13.2 Douser Motor
The Douser Motor is located in the lamp compartment behind the reflector assembly.
(Estimated Replacement Time: 12 m 10
minute LampLOC™ Alignment)
1. Remove front top lid. Refer to
2. Rotate the rear top lid to gain access to the douser
bracket.
3. Remove the rear skin. Refer to
.
4. Using a 3mm hex key, remove the three screws
securing the douser bracket. (
Figure 5-52
)
5. Disconnect the harness from the IMCB.
6. Slide the douser assembly back, and lift up and out
from the top of the projector.
7. When installing, repeat instructions in reverse. Once installed, perform LampLOC
™
alignment. See
Adjusting Lamp Position (LampLOC™), on page 3-3
5.13.3 Ceramic Plate on Douser Blade
The ceramic plate is located in the lamp compartment and is mounted to the douser blade. It is used to absorb
heat from the light emitted by the lamp.
(Estimated Replacement Time: 4 m 10 minute LampLOC
™
Alignment)
1. Open the lamp door. Refer to
2. Remove the lamp (if installed). Refer to
.
3. Using a #2 Phillips
™
, remove the four screws securing the
ceramic plate to the douser blade. (
Figure 5-53
)
4. When installing, repeat instructions in reverse. Once
installed, perform LampLOC
™
alignment. See
Lamp Position (LampLOC™), on page 3-3
.
Figure 5-52 Douser Motor
Figure 5-53 Ceramic Plate