CP2220 Setup Guide
2-1
020-100476-05 Rev. 1 (05-2014)
2 Installation and Setup
This section provides information and procedures for positioning and installing the cinema projector.
2.1
Site Requirements
To safely install and operate the CP2220 cinema projector, the installation location must meet these minimum
requirements:
• Physical Operating Environment
• Maximum Ambient Temperature (operating) 35°C
• Minimum Ambient Temperature (operating) 10°C
• External Exhaust Ducting
• The installation site must provide a minimum of 450 CFM (ft
3
/min) external exhaust airflow to ensure
adequate cooling of the Xenon arc lamp at less than or equal to 25°C ambient and less than 3,000 feet ele-
vation. Above 25°C or 3,000 feet, 600 CFM is required. For detailed instructions for measuring CFM,
see
2.8 Connect External Exhaust Ducting, on page 2-8.
•
Permanent Power Connection
• A
30-32A double pole, UL listed
wall circuit breaker is required. It must be part of the building installa-
tion and easily accessible.
• Single-phase 30A connection of AC supply to the terminal block.
• Protection from overcurrents, short circuits, and earth faults must be part of the building installation. The
disconnect device (double pole switch or circuit breaker with minimum 3mm contact gap) must be readily
accessible within the projection room.
2.2
Tools Required for Installation
You need these tools to install the CP2220 cinema projector:
• 12” screwdrivers: Phillips #2 (magnetic) and flat
• 19mm and 7/8” wrenches
• Assorted Allen keys (metric)
• Heat extractor
• Christie approved protective safety clothing if you are working with the lamp
• Lamp
• Lens cleaning tissue and solution