Use this section for service procedures and test inspection criteria.
Test Equipment Needed
• PC or laptop with WUXGA/1080p resolution
• DVD player with Multi-system, equipped "Component", "S-Video", "Composite" and "HDMI".
• HDTV Source (480P, 720P, 1080P)
• Quantum Data 802B or CHROMA2327 (Color Video Signal & Pattern Generator)
• CL200 or CL200A
Factory Mode
Enter into Factory Mode
1. Turn on the projector.
2. On the Remote or Keypad, press Power, left, right, menu buttons sequentially.
On-Screen Display (OSD) Reset
Use this procedure to erase all end-user settings and restore the default OSD setting:
1. Enter Factory Mode, as described in
2. Select Factory Reset.