Command
Description
Values
LAS+WHTX <value>
Defines the white x color target value. The
value is expressed with four decimal points.
(Saved value)
Only applies to: Christie M RGB Series and
Griffyn Series
2500 to 4500, where 4500 = 0.4500
3127 (Default)
LAS+WHTY <value>
Defines the white y color target value. The
value is expressed with four decimal points.
(Saved value)
Only applies to: Christie M RGB Series and
Griffyn Series
2500 to 4500, where 4500 = 0.4500
3290 (Default)
Examples
Enable LiteLOC:
(LAS+MODE 0)
Disable the green laser:
(LAS+EGRN 0)
Change the red laser drive level to 100%:
(LAS+REDP 1000)
Return the color sensor Z reading:
(LAS+CSRZ?)
Set the expected maximum ambient temperature to 25°C:
(LAS+MAXA 25)
Adjust the overall output of the lasers to 80%:
(LAS+POWR 800)
LCB–Lens Motor Calibration
Calibrates all of the lens motors.
This command is only enabled when the projector is on.
Commands
Command
Description
Values
LCB 1
Runs calibration on all lens motors.
1
LCB+HOME
Moves all lens motors back to the center flag for each
axis and sets their respective positions to 0.
—
LCB+LOCK <0 | 1>
Locks all lens motors preventing the lens from moving.
This overrides all other lens functions.
0 = Unlocks motors (Default)
1 = Locks motors
Serial API commands
Christie Technical Reference–Serial Commands
41
020-103316-07 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.