background image

BARCO PROJECTION SYSTEMS

Date :
151101

INSTALLATION MANUAL

KIT ANALYSER FOR 6500/6400I, RSIM6(HB/HBMLA/LL) & HELIOS PROJECTORS

R817211K

R8172112K

R820349K

R8172122K

R8172121K

R817214K

R821060K

R8172132K

Art. No. :

R5976207

Rev :

01

ANALYSER

6500 Kit

Summary of Contents for R8172112K

Page 1: ...YSTEMS Date 151101 INSTALLATION MANUAL KIT ANALYSER FOR 6500 6400I RSIM6 HB HBMLA LL HELIOS PROJECTORS R817211K R8172112K R820349K R8172122K R8172121K R817214K R821060K R8172132K Art No R5976207 Rev 01 ANALYSER 6500 Kit ...

Page 2: ...Produced by BARCO NV November 2001 All rights reserved Trademarks are the rights of their respective owners BARCO n v Projection Systems Noordlaan 5 B 8520 Kuurne Belgium Tel 32 56 368211 Fax 32 56 351651 E mail sales bps barco com Visite Barco at the web http www barco com Printed in Belgium ...

Page 3: ...k of Electrical Shock Power down the projector and unplug the power cord from the wall outlet Once the projector is cooled down and the power is off continue with the replacement procedure Antistatic Protection Steps Wear a wrist band which is connected to the ground while handling the static sensitive parts Sensitive Device LCD panels are very sensitive devices Observe full precautions for handli...

Page 4: ...d R5976207 1 1 1 1 1 Analyser red Analyser green Analyser green for SSS cube Analyser blue Manual ins analyser 6500 RSIM6 Helios Part Number Description Qty Antistatic Protection Steps Wear a wrist band which is connected to the ground while handling the static sensitive parts Analyser Kits Where used Analyser Red R817211K Analyser Green R820349K Analyser Gr SSS R8172121K Analyser Bleu R821060K An...

Page 5: ...part and pivote it upwards Open both lens locks by pulling them backwards Take the lens out of the lens house Step Action Image To be continued on next page Necessary Parts None Illustrations on Removing the Lens Image 2 Image 1 Lens lockings Motor part Fixation screws What has to be done The lens has to be removed and the top cover has to be opened For projectors with a black cover it is not nece...

Page 6: ...ube Continued Removing the Top Cover 1 2 3 1 2 Pull the 3 rubber sealing pieces Turn out the 3 fixing screws Take off the top cover Step Action Image To remove the top cover follow the next procedure Illustrations on Top Cover Removal Image 1 Image 2 ...

Page 7: ...s Philips screwdriver Necessary Parts None 1 2 3 4 5 1 1 2 Begin with unscrewing the screw B retaining the elecrical conductor Turn out the screws retaining the little plate A Remove the little plate Turn carefuly the remaining screws out be aware not to drop these screws into the apparatus Remove the EMC plate Step Action Image Removing the plate Illustrations Image 1 ...

Page 8: ...very carefully on both sides of the indicated points to unlock Pull out the cable Step Action Illustration Press to lock Press to unlock Connector connector cable Necessary Parts None Removing the X Cube Adjustment Unit To remove the LCD X cube unit together with the adjustment unit follow the next procedure 1 2 3 1 1 Unplug the power cable Loosen both fixing screws down under by inserting Philips...

Page 9: ...e X Cube assembly it must be electrically disconnected from the adjustment board Follow the next procedure 1 2 Press very carefully on both sides of the indicated points to unlock Pull out the cable see image 1 Step Action Illustration Press to lock Press to unlock Connector connector cable Necessary Parts None Tip While removing the screws and the parts put them on a row to find them back the cor...

Page 10: ...2 Image 3 Disassembling the X cube Assembly To disassemble the X cube assembly follow the next procedure 1 2 3 4 1 2 2 3 Turn out the 4 fixing screws with Philips screwdriver Take off the unit Turn out the 4 fixing screws with a nutdriver 5 5 o flat screwdriver Take off the metal holder Step Action Image ...

Page 11: ...ld analyser has to be removed Necessary Tools None Necessary Parts None To be continued on next page Analyser Position The analyser can be found between the LCD panel and the X cube see image 1 1 Red side X cube 2 Green side X cube 3 Blue side X cube 1 3 2 Illustration Image 1 ...

Page 12: ...move the analyser follow the next procedure 1 2 1 2 Free the analyser by pushing it backwards an pulling it out therefore use the thumb the index and the middlefinger Slide out the analyser carefully Avoid making scratches into the LCD panel Step Action Image Illustration Image 1 Image 2 ...

Page 13: ...rotection coating from the new analyser With the sealed side to the LCD panel slide in the analyser carefully Avoid making scratches into the LCD panel or X cube Hook the bottom side in the gap between the metal holder and the X cube Push with both fingers as shown on the image until the analyser hooks on the 2 clips Step Action Image Illustration Image 1 What has to be done The new analyser has t...

Page 14: ...BARCO 14 Projection Systems Mounting the Analyser Continued Illustration Image 1 ...

Page 15: ... disassembled part and continue to the first one in the queu To be continued on next page Illustration Image 1 Image 2 Assembling the X cube Assembly To assemble the X cube assembly follow the next procedure 1 2 3 4 Put the metal unit holder on its place Turn in the 4 fixing screws with a nutdriver or flat screw driver Put the adjustment unit on its place Secure this position with the 4 fixing scr...

Page 16: ...Electrical Connection of the X Cube Electrically connected to the adjustment board Follow the next procedure 1 2 Insert the cable see image Press very carefully on both sides of the indicated points to lock Step Action Illustration Press to lock Press to unlock Connector connector cable ...

Page 17: ...y inserting a flat screwdriver Step Action Image To mount the LCD X cube follow the next procedure Electrical Connection of the X Cube Mounting the X Cube it must be electrically connected to the driver board Follow the next procedure 1 2 3 Insert the cable into the connector Press very carefully on both sides of the indicated points to lock Mount the power cable Step Action Illustration Press to ...

Page 18: ...ot always present Necessary Tools Philips screwdriver Necessary Parts None 1 2 3 4 5 1 2 1 1 2 Put the plate back on the PMP Turn in the indicated screws Put the little plate A back on its place and fix it with the 2 screws Fix the cable B with its screw Turn the remaining screws in Step Action Image Illustrations Image 2 Image 1 Remounting the EMC plate ...

Page 19: ...er has to be remounted Necessary Tools Screwdriver 8 mm Necessary Parts None To be continued on next page Installing the Top Cover 1 2 3 1 2 Put the top cover on the projector Turn in the 3 fixing screws Cover the fixing screws with the rubber sealing pieces Step Action Image To install the top cover follow the next procedure Illustrations on Top Cover installation Image 1 Image 2 ...

Page 20: ...e D to the upside if a motorized lens Fix the lens by closing the both locks until they are se cured Pivot the motor part fully downwards Ensure that the teeth of the motor matches 100 those of the tooth profile only for a motorized lens If not turn the lens a little While pushing down tighten wing bolts B firmly to ensure good functioning of safety latches and motorization Reinstall the lens cove...

Reviews: