Serial Command Reference
Matrix StIM™ WQ/SIM WQ User Manual
115
020-100883-01 Rev. 2 (06-2013)
Real Time Events (RTE)
RTE
CONTROL GROUP:
Unsaved
SUBCLASS:
Power Down
ACCESS LEVEL:
Operator
Description
Real time events allow custom user actions to occur based on a system trigger. There are various triggers in the
system such as power up, input change, errors, or based on time. Time can be absolute, (e.g. 12:00:00 on
December 25, 2008) or relative (e.g. 5 hours and 30 minutes from now).
Special Function keys can also be used as a trigger. An example would be pressing
F
UNC
+1
on the remote.
Events can also be connected to external hardware triggers via the General Purpose IO port (GPIO).
Events:
Single Occurrence Events:
(RTE T YYYY/MM/DD HH:MM:SS S "description" "command")
Daily Occurring Event:
(RTE T YYYY/MM/DD HH:MM:SS YYYY/MM/DD D R "description" "command")
Where the first date and time is the start date and occurrence time. The second date is the end date.
R is the "Repeat Every" interval i.e. repeat every R days
Weekly Occurring Event:
(RTE T YYYY/MM/DD HH:MM:SS YYYY/MM/DD W R "D" "description" "command")
Where the first date and time is the start date and occurrence time. The second date is the end date.
R is the "Repeat Every" interval i.e. repeat every R weeks
D is the weekday or weekdays that the command should run on:
M = Monday
W = Wednesday
F = Friday Su = Sunday
Tu = Tuesday
Th = Thursday
S = Saturday
I.E. "MT" will run on Monday and Tuesday "TTh" will run on Tuesday and Thursday "MTWFSSu" will run on
Monday, Tuesday, Wednesday, Friday, Saturday, and Sunday
Monthly Occurring Event:
(RTE T YYYY/MM/DD HH:MM:SS YYYY/MM/DD M R "description" "command")
Where the first date and time is the start date and occurrence time. The second date is the end date.
R is the "Repeat Every" interval i.e. repeat on the same date every R months
NOTE:
If there are not 31 days in the next run cycle month, the event will not run in that month.
Function Key Events:
(RTE F K "description" "command"), where K = the specific function key (1-5,7-9). Key 6 is reserved and cannot
be used.
System Events:
(RTE S E T "description" "command"), where E is the event to respond to:
0 = Boot Up
1 = Power ON/OFF
T = 0 (Either a Power ON or OFF event)
T = 1 (Power ON only)
T = 2 (Power OFF only)
2 = Any System Error
3 = Good Signal
4 = No Signal
5 = Input Change
Summary of Contents for 130-002103-01
Page 1: ...Matrix StIM WQ SIM WQ U s e r M a n u a l 020 100883 01...
Page 2: ......
Page 3: ...Matrix StIM WQ SIM WQ U S E R M A N U A L 020 100883 01...
Page 6: ......
Page 16: ......
Page 36: ......
Page 80: ......
Page 86: ......
Page 88: ......
Page 138: ......
Page 142: ......
Page 143: ...000 103893 01 ASSY TECH DOCS Matrix StIM WQ SIM WQ...