Serial Command Reference
Matrix StIM™ WQ/SIM WQ User Manual
97
020-100883-01 Rev. 2 (06-2013)
Fan Assist (FAS)
Frame Lock Enable (FLE)
FAS
CONTROL GROUP:
Saved
SUBCLASS:
Power Down
ACCESS LEVEL:
Operator
Description
This control is used to increase fan speed in environments with high ambient temperatures. Default of 0 will use
normal fan speed control which should be sufficient under normal circumstances. To increase fan speed select
larger values.
Subcode
<No Subcode >
Description of Use
Examples:
(FAS 25) Use fan assist.
(FAS 0) Use default fan speed control.
FLE
CONTROL GROUP:
Saved
SUBCLASS:
Power Down
ACCESS LEVEL:
Operator
Description
This controls which input is used to control the output frame timing. When set to Lock, output image frames are
locked to the main input. When set to Lock Secondary, the output is locked to the secondary input (provided one
is present).
Subcode
<No Subcode >
Description of Use
Sets input used to lock output.
Examples:
(FLE 1) Enables frame lock.
(FLE 2) Enables frame lock.
(FLE ?) Get frame lock enabled status.