Control Installation
Chore-Tronics® 3 Control
98
MT2398C
To route the Static Pressure Hoses into the Chore-Tronics
®
3 Main Box, first drill two 5/8" holes in the
side of the Box, next to the sensor. Place a ½" water tight connector
(Item 3, Figure 24)
into each hole
and tighten using the hardware provided. Route a 3/16" ID hose
(Chore-Time part number 43071)
through each of the Water Tight Connectors. Connect one hose to the low pressure barb on the SP module,
and run that house into the house. Connect another hose to the high pressure barb on the Sp Module. Run
that hose into the attic or to outside air. Make sure the high pressure hose is in still air. Once the hoses
have been routed and connected, place the Barb Reducer Plugs into the end of the hose opposite of the SP
sensor.
2
1
Item
Description
1
Static Pressure Sensor
2
Static Pressure Hose
3
1/2" Water Tight Connector
4
Barb Reducer Plugs
Figure 24. Static Pressure Sensor Hose Routing
Low Pressure Barb
High Pressure Barb
Run into Attic
Run into House
4
3