5

Follow Safety Instructions

Carefully read all safety messages in this manual and on your equipment safety signs. Follow recommended 
precautions and safe operating practices.

Keep safety signs in good condition. Replace missing or damaged safety signs.

Decal Descriptions

DANGER: Electrical Hazard

Disconnect electrical power before inspecting or servicing equipment 
unless maintenance instructions specifically state otherwise.

Ground all electrical equipment for safety.

All electrical wiring must be done by a qualified electrician in accordance 
with local and national electric codes.

Ground all non-current carrying metal parts to guard against electrical 
shock.

With the exception of motor overload protection, electrical disconnects and 
over current protection are not supplied with the equipment.

Support Information

The Chore-Time 4 and 8 Station Pneumatic Drinking System (PDS™) Control is designed to control water line 
regulators in a Chore-Time Nipple Watering System. Using this equipment for any other purpose or in a way not 
within the operating recommendations specified in this manual will void the warranty and may cause personal 
injury.

This manual is designed to provide comprehensive planning and installation information. The Table of Contents 
provides a convenient overview of the information in this manual.

Installation Information

Please read the installation instructions in this manual prior to beginning the installation. This manual provides 
the necessary information on the installation, operation and maintenance of the Chore-Time equipment you have 
purchased.

The 4 and 8 Station PDS™ Control is available in as either a 4 or 8 station control. Each station is capable of 
controlling up to two (2) individual VOLUMATIC™ regulators. For example a 4 station control can regulate and 
flush up to 8 individual water regulators.

Compressed air must be available and regulated between 6 and 12 psi 

[41.37 and 68.95 kPa].

 Each PDS™ control 

consumes a low volume of air when in operation. Therefore, one centrally located air compressor with a holding 
tank can easily supply enough air for multiple PDS™ controls. See “Compressed Air Supply” on page 9 of this 
manual for recommended air compressor specifications.

Safety Instructions

General

Summary of Contents for 49000-4

Page 1: ...PDS Control 4 and 8 Station Pneumatic Drinking System Installation and Operators Manual MW1402D August 2008...

Page 2: ...considered defects under the Warranty 5 This Warranty applies only to systems for the care of poultry and livestock Other applications in industry or commerce are not covered by this Warranty Chore Ti...

Page 3: ...ultiple House Layout 6 Installation 7 Wiring 7 CHORE TRONICS 7 Tubing 9 Compressed Air Supply 9 Water Column Gauge Calibration 10 Air Leak Test 10 Operation 11 Flushing The System 11 Flushing Recommen...

Page 4: ...ntent that is different from the authoritative CTB published English version of the manual For current product installation and operation information please contact the customer service and or technic...

Page 5: ...t for any other purpose or in a way not within the operating recommendations specified in this manual will void the warranty and may cause personal injury This manual is designed to provide comprehens...

Page 6: ...talling the PDS system Refer to Parts List Section page 15 for item part numbers Broiler System Layout Figure 1 Broiler Layout Multiple House Layout Figure 2 4 House Layout Air can be run from a centr...

Page 7: ...rol is still disconnected and no backup battery is installed All wiring must be done by a qualified electrician in accordance with local and national codes CHORE TRONICS When using CHORE TRONICS to mo...

Page 8: ...tation 8 MW1402D Figure 4 Rain Bird Chore Tronics Wiring Figure 5 Internal Wiring OPTIONAL SECOND I O BOARD MODEL 32 40 ONLY CHORE TRONICS CONTROL 24VAC COIL RELAY NOT SUPPLIED Rain Bird Timer 8 7 6 5...

Page 9: ...regulator with 1 4 fitting and has adjustable range of 0 125 psi Approved air regulators Grainger Industrial Supply Part number 4ZMO8 Grainger Industrial Supply Part number 4ZMO6 NAPA Part number 90...

Page 10: ...he water column gauge remove the plastic cover with a small screwdriver Then turn the calibration screw see figure 9 until the gauge reads the correct water column height Replace the plastic cover on...

Page 11: ...all of them running all the start times in the undesired programs must be set to off The unused programs except the start times are retained but will not run until the start times are re entered This...

Page 12: ...s TotalLine Capacity 17 0 Gallons TotalLine Capacity 20 4 Gallons TotalLine Capacity 23 8 Gallons TotalLine Capacity 27 2 Gallons Gallons of water in one foot of 3 4 Chore Time water pipe 034 Water Li...

Page 13: ...often until these problems disappear The sediments could react with medications vaccines and electrolytes They will also hamper the effects of disinfectants and cleaners chlorine and acids Flushing Af...

Page 14: ...air source and that house 2 With the incoming air off and the gauge indicates that there is a 2 PSI drop or more within 1 minute the problem is in the control lines or regulators 3 Shut off or pinch o...

Page 15: ...19 Control Decal 2529 883 2529 883 7 Control Box Latch Pivot 30863 30863 20 Pigtail Connector 5907 1 5907 1 8 Airloader W Adjustment Knob 48837 48584 21 120V Timer Control 50819 1 50819 2 9 1 4 OD 1...

Page 16: ...ore Time distributor or representative for additional parts and information CTB Inc P O Box 2000 Milford Indiana 46542 2000 U S A Phone 574 658 4101 Fax 877 730 8825 E mail poultry choretime com Inter...

Reviews: