Chore-Time 49000-4 Installation And Operator'S Manual Download Page 12

Flushing The System

PDS™ Control 4 and 8 Station

12

MW1402D

Minutes to Flush and Total Line Capacity 

for Chore-Time Nipple Systems

Estimated flush times above are to completely exchange the water in the pipe. The water line length must include 

the length of the supply line from the water source to completely exchange the water. The flush time to stimulate 

bird drinking may be less, depending on the frequency of flushes.

Water Line Length in Feet

100’

200’

300’

400’

500’

600’

700’

800’

G

a

llo

ns

 pe

r Mi

nu

te

 

Fl

ow Rate

1

3.4

6.8

10.2

13.6

17.0

20.4

23.8

27.2

2

1.7

3.4

5.1

6.8

8.5

10.2

11.9

13.6

3

1.1

2.3

3.4

4.5

5.7

6.8

7.9

9.1

4

0.9

1.7

2.6

3.4

4.3

5.1

6.0

6.8

5

0.7

1.4

2.0

2.7

3.4

4.1

4.8

5.4

6

0.6

1.1

1.7

2.3

2.8

3.4

4.0

4.5

7

0.5

1.0

1.5

1.9

2.4

2.9

3.4

3.9

8

0.4

0.9

1.3

1.7

2.1

2.6

3.0

3.4

Estimated Flush Time in Minutes

Total Line 

Capacity 

3.4 

Gallons

Total Line 

Capacity 

6.8 

Gallons

Total Line 

Capacity 

10.2 

Gallons

Total Line 

Capacity 

13.6 

Gallons

Total Line 

Capacity 

17.0 

Gallons

Total Line 

Capacity 

20.4 

Gallons

Total Line 

Capacity 

23.8 

Gallons

Total Line 

Capacity 

27.2 

Gallons

Gallons of water in one foot of 3/4" Chore-Time water pipe=.034

Water Line Length in Meters

30m

60m

90m

120m

150m

180m

210m

240m

Lite

rs

 Pe

r Mi

nu

te

Fl

ow Rate

4

3.2

6.3

9.5

12.7

15.8

19.0

22.2

25.3

6

2.1

4.2

6.3

8.4

10.6

12.7

14.8

16.9

8

1.6

3.2

4.7

6.3

7.9

9.5

11.1

12.7

10

1.3

2.5

3.8

5.1

6.3

7.6

8.9

10.1

12

1.1

2.1

3.2

4.2

5.3

6.3

7.4

8.4

14

0.9

1.8

2.7

3.6

4.5

5.4

6.3

7.2

16

0.8

1.6

2.4

3.2

4.0

4.7

5.5

6.3

18

0.7

1.4

2.1

2.8

3.5

4.2

4.9

5.6

20

0.6

1.3

1.9

2.5

3.2

3.8

4.4

5.1

22

0.6

1.2

1.7

2.3

2.9

3.5

4.0

4.6

24

0.5

1.1

1.6

2.1

2.6

3.2

3.7

4.2

26

0.5

1.0

1.5

1.9

2.4

2.9

3.4

3.9

28

0.5

0.9

1.4

1.8

2.3

2.7

3.2

3.6

30

0.4

0.8

1.3

1.7

2.1

2.5

3.0

3.4

Estimated Flush Time in Minutes

Total 

Line 

Capacity 

12.7 

Liters

Total 

Line 

Capacity 

25.3 

Liters

Total 

Line 

Capacity 

38.0 

Liters

Total 

Line 

Capacity 

50.6 

Liters

Total 

Line 

Capacity 

63.3 

Liters

Total 

Line 

Capacity 

76.0 

Liters

Total 

Line 

Capacity 

88.6 

Liters

Total 

Line 

Capacity 

101.3 

Liters

Liters of water in one meter of 3/4" (1.90 cm) Chore-Time water pipe=.422

Summary of Contents for 49000-4

Page 1: ...PDS Control 4 and 8 Station Pneumatic Drinking System Installation and Operators Manual MW1402D August 2008...

Page 2: ...considered defects under the Warranty 5 This Warranty applies only to systems for the care of poultry and livestock Other applications in industry or commerce are not covered by this Warranty Chore Ti...

Page 3: ...ultiple House Layout 6 Installation 7 Wiring 7 CHORE TRONICS 7 Tubing 9 Compressed Air Supply 9 Water Column Gauge Calibration 10 Air Leak Test 10 Operation 11 Flushing The System 11 Flushing Recommen...

Page 4: ...ntent that is different from the authoritative CTB published English version of the manual For current product installation and operation information please contact the customer service and or technic...

Page 5: ...t for any other purpose or in a way not within the operating recommendations specified in this manual will void the warranty and may cause personal injury This manual is designed to provide comprehens...

Page 6: ...talling the PDS system Refer to Parts List Section page 15 for item part numbers Broiler System Layout Figure 1 Broiler Layout Multiple House Layout Figure 2 4 House Layout Air can be run from a centr...

Page 7: ...rol is still disconnected and no backup battery is installed All wiring must be done by a qualified electrician in accordance with local and national codes CHORE TRONICS When using CHORE TRONICS to mo...

Page 8: ...tation 8 MW1402D Figure 4 Rain Bird Chore Tronics Wiring Figure 5 Internal Wiring OPTIONAL SECOND I O BOARD MODEL 32 40 ONLY CHORE TRONICS CONTROL 24VAC COIL RELAY NOT SUPPLIED Rain Bird Timer 8 7 6 5...

Page 9: ...regulator with 1 4 fitting and has adjustable range of 0 125 psi Approved air regulators Grainger Industrial Supply Part number 4ZMO8 Grainger Industrial Supply Part number 4ZMO6 NAPA Part number 90...

Page 10: ...he water column gauge remove the plastic cover with a small screwdriver Then turn the calibration screw see figure 9 until the gauge reads the correct water column height Replace the plastic cover on...

Page 11: ...all of them running all the start times in the undesired programs must be set to off The unused programs except the start times are retained but will not run until the start times are re entered This...

Page 12: ...s TotalLine Capacity 17 0 Gallons TotalLine Capacity 20 4 Gallons TotalLine Capacity 23 8 Gallons TotalLine Capacity 27 2 Gallons Gallons of water in one foot of 3 4 Chore Time water pipe 034 Water Li...

Page 13: ...often until these problems disappear The sediments could react with medications vaccines and electrolytes They will also hamper the effects of disinfectants and cleaners chlorine and acids Flushing Af...

Page 14: ...air source and that house 2 With the incoming air off and the gauge indicates that there is a 2 PSI drop or more within 1 minute the problem is in the control lines or regulators 3 Shut off or pinch o...

Page 15: ...19 Control Decal 2529 883 2529 883 7 Control Box Latch Pivot 30863 30863 20 Pigtail Connector 5907 1 5907 1 8 Airloader W Adjustment Knob 48837 48584 21 120V Timer Control 50819 1 50819 2 9 1 4 OD 1...

Page 16: ...ore Time distributor or representative for additional parts and information CTB Inc P O Box 2000 Milford Indiana 46542 2000 U S A Phone 574 658 4101 Fax 877 730 8825 E mail poultry choretime com Inter...

Reviews: