Chore-Time 49000-4 Installation And Operator'S Manual Download Page 2

Warranty

PDS™ Control 4 and 8 Station

2

MW1402D

C

hore-Time Poultry Production Systems, 

a division of CTB, Inc., (“Chore-Time”), warrants each new 

CHORE-TIME® product manufactured by it to be free from defects in material or workmanship for one (1) year 
from and after the date of initial installation by or for the original purchaser.  If such a defect is found by Chore-
Time to exist within the one-year period, the Chore-Time will, at its option, (a) repair or replace such product free 
of charge, F.O.B. the factory of manufacture, or (b) refund to the original purchaser the original purchase price, 
in lieu of such repair or replacement.  Labor costs associated with the replacement or repair of the product are not 
covered by the Manufacturer.

Conditions and Limitations

1. The product must be installed by and operated in accordance with the instructions published by the 

Manufacturer or Warranty will be void

.

2. Warranty is void if 

all components

 of the system are not original equipment supplied by the 

Manufacturer

.

3. This product must be purchased from and installed by an authorized distributor or certified representative 

thereof or the Warranty will be void.

4. "Malfunctions or failure resulting from misuse, abuse, mismanagement,  negligence, alteration, accident, or 

lack of proper maintenance, or from lightning strikes, electrical power surges or interruption of electricity 
shall not be considered defects under the Warranty.  Corrosion, material deterioration and/or equipment 
malfunction caused by or consistent with excessive additions of chemicals, minerals, sediments or other 
foreign elements with the product shall not be considered defects under the Warranty."

5. This Warranty applies only to systems for the care of poultry and livestock. Other applications in industry 

or commerce are not covered by this Warranty.

Chore-Time shall not be liable for any 

Consequential or Special Damage

 which any purchaser may suffer or 

claim to suffer as a result of any defect in the product.  

“Consequential”

 or 

“Special Damages”

 

as used herein 

include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders, 
lost income, increased overhead, labor and incidental costs and operational inefficiencies.

THIS WARRANTY CONSTITUTES THE MANUFACTURER’S ENTIRE AND SOLE WARRANTY AND 
THIS MANUFACTURER DISCLAIMS ANY AND ALL OTHER WARRANTIES, INCLUDING, BUT NOT 
LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTABILITY, FITNESS FOR 
PARTICULAR PURPOSES SOLD AND DESCRIPTION OR QUALITY OF THE PRODUCT FURNISHED 
HEREUNDER.

Chore-Time Distributors are not authorized to modify or extend the terms and conditions of this Warranty in any 
manner or to offer or grant any other warranties for CHORE-TIME® products in addition to those terms expressly 
stated above. An officer of CTB, Inc. must authorize any exceptions to this Warranty in writing.  Chore-Time 
reserves the right to change models and specifications at any time without notice or obligation to improve previous 
models.

Effective: 

August 2008

Chore-Time Poultry Production Systems

A Division of CTB, Inc.

410 N. Higbee Street • Milford, Indiana 46542 • U.S.A.

Phone (574) 658-4101 • Fax (877) 730-8825

E-mail: [email protected] • Internet: www.choretimepoultry.com

Thank You

The 

employees of CTB, Inc. would like to thank your for your recent Chore-Time purchase. If a problem should 

arise, your Chore-Time distributor can supply the necessary information to help you.

Warranty

Summary of Contents for 49000-4

Page 1: ...PDS Control 4 and 8 Station Pneumatic Drinking System Installation and Operators Manual MW1402D August 2008...

Page 2: ...considered defects under the Warranty 5 This Warranty applies only to systems for the care of poultry and livestock Other applications in industry or commerce are not covered by this Warranty Chore Ti...

Page 3: ...ultiple House Layout 6 Installation 7 Wiring 7 CHORE TRONICS 7 Tubing 9 Compressed Air Supply 9 Water Column Gauge Calibration 10 Air Leak Test 10 Operation 11 Flushing The System 11 Flushing Recommen...

Page 4: ...ntent that is different from the authoritative CTB published English version of the manual For current product installation and operation information please contact the customer service and or technic...

Page 5: ...t for any other purpose or in a way not within the operating recommendations specified in this manual will void the warranty and may cause personal injury This manual is designed to provide comprehens...

Page 6: ...talling the PDS system Refer to Parts List Section page 15 for item part numbers Broiler System Layout Figure 1 Broiler Layout Multiple House Layout Figure 2 4 House Layout Air can be run from a centr...

Page 7: ...rol is still disconnected and no backup battery is installed All wiring must be done by a qualified electrician in accordance with local and national codes CHORE TRONICS When using CHORE TRONICS to mo...

Page 8: ...tation 8 MW1402D Figure 4 Rain Bird Chore Tronics Wiring Figure 5 Internal Wiring OPTIONAL SECOND I O BOARD MODEL 32 40 ONLY CHORE TRONICS CONTROL 24VAC COIL RELAY NOT SUPPLIED Rain Bird Timer 8 7 6 5...

Page 9: ...regulator with 1 4 fitting and has adjustable range of 0 125 psi Approved air regulators Grainger Industrial Supply Part number 4ZMO8 Grainger Industrial Supply Part number 4ZMO6 NAPA Part number 90...

Page 10: ...he water column gauge remove the plastic cover with a small screwdriver Then turn the calibration screw see figure 9 until the gauge reads the correct water column height Replace the plastic cover on...

Page 11: ...all of them running all the start times in the undesired programs must be set to off The unused programs except the start times are retained but will not run until the start times are re entered This...

Page 12: ...s TotalLine Capacity 17 0 Gallons TotalLine Capacity 20 4 Gallons TotalLine Capacity 23 8 Gallons TotalLine Capacity 27 2 Gallons Gallons of water in one foot of 3 4 Chore Time water pipe 034 Water Li...

Page 13: ...often until these problems disappear The sediments could react with medications vaccines and electrolytes They will also hamper the effects of disinfectants and cleaners chlorine and acids Flushing Af...

Page 14: ...air source and that house 2 With the incoming air off and the gauge indicates that there is a 2 PSI drop or more within 1 minute the problem is in the control lines or regulators 3 Shut off or pinch o...

Page 15: ...19 Control Decal 2529 883 2529 883 7 Control Box Latch Pivot 30863 30863 20 Pigtail Connector 5907 1 5907 1 8 Airloader W Adjustment Knob 48837 48584 21 120V Timer Control 50819 1 50819 2 9 1 4 OD 1...

Page 16: ...ore Time distributor or representative for additional parts and information CTB Inc P O Box 2000 Milford Indiana 46542 2000 U S A Phone 574 658 4101 Fax 877 730 8825 E mail poultry choretime com Inter...