ChoiceMMed MD300W11 Instruction Manual Download Page 12

V1.0W11                                                                                                                                                                WRIST PULSE OXIMETER  

                                                                                                               

12 

 

Pic.8 

NOTE: DO NOT insert the sensor incorrectly; otherwise there is no Oxygen Saturation signal.   

1. 

Place  the  user

’s  finger  inside  the  sensor.  Refer  to  the  respective  sensor  instructions  for  specific 

information about placement and user safety, shown as picture 9.

   

2. 

Place  the  user

’s  finger  inside  the  sensor.  Refer  to  the  respective  sensor  instructions  for  specific 

information about placement and user safety, shown as picture 9. 

 

 
 
 
 

 
 

Pic.9 

 
 
 

 

Summary of Contents for MD300W11

Page 1: ...WRIST PULSE OXIMETER INSTRUCTION MANUAL Non Medical Equipment Edition V1 0W11...

Page 2: ...his manual may not copy use or disclose the information in this work unless expressly authorized by our company to do so All information contained in this manual is believed to be correct Our company...

Page 3: ...osive atmosphere or in the presence of flammable anesthetics or gas Warnings General operation of the Wrist Oximeter might be affected by the presence of an electrosurgical unit ESU The wrist oximeter...

Page 4: ...device should be observed carefully to verify normal operation The use of accessories sensors and cables other than those listed in this manual may result in increased emission and or decreased immuni...

Page 5: ...t be repaired by trained personnel only The wrist oximeter measures arterial oxygen saturation of functional hemoglobin Significant levels of dysfunctional hemoglobin caused by sickle cell anemia carb...

Page 6: ...V1 0W11 WRIST PULSE OXIMETER 6 Contents of package One 1 5V AAA alkaline Battery An instruction manual Finger clip sensor model M 50G07CSO One reusable wristband MedView software CD Data cable...

Page 7: ...nserting and Replacing the Batteries 10 3 Setting up the Wrist Oximeter and Attaching the Sensor 11 4 Measurement 17 5 Specifications 18 6 Error code 21 7 Key symbols 21 8 Maintenance and storage 22 9...

Page 8: ...ng or after sport activities It is intended to be used by outdoor sport enthusiast mountain climber high altitude sporter and gymnasium exerciser Scope of application Outdoor sport Athletics sport Gym...

Page 9: ...for a long time you can turn on or turn off the unit under setting menu press this button for a short time you can set the data Low battery voltage Sensor 1 2 Product Features Exquisite compact light...

Page 10: ...g to local applicable regulations 4 Carefully re position the battery cover Do not force the cover into place it fits only when positioned properly 5 If the wrist oximeter does not turn on when you pr...

Page 11: ...hould be threaded first 2 Continue threading the wrist strap until it is pulled securely through both spring bars on the rear of the Wrist Oximeter Pic 3 Pic 4 Pic 5 3 Press the long segment of the wr...

Page 12: ...lace the user s finger inside the sensor Refer to the respective sensor instructions for specific information about placement and user safety shown as picture 9 2 Place the user s finger inside the se...

Page 13: ...ering on the following information will appear shown as Pic 11 If the probe is inserted into the oximeter but no finger the information will be shown as Pic 12 Pic 11 Pic 12 Pic 13 Regardless of the i...

Page 14: ...re shown as picture 14 Press button to set the right year The setting range is 0 20 it means that the year is from 2000 to 2020 After finishing setting the year press the button for about one second t...

Page 15: ...to enter into the hour setting screen or press the button for about three seconds to return to the measuring screen Pic 16 3 2 2 4 Hour setting After finishing setting the date press the button for ab...

Page 16: ...ing screen or press the button for about three seconds to return to the measuring screen Pic 18 3 2 2 6 Second setting After finishing setting the minute press the button for about one second to enter...

Page 17: ...20 Refer to the respective sensor instructions for specific information about placement and user safety The signal searching picture is shown as Pic 21 Pic 20 Pic 21 Pic 22 2 The measuring result show...

Page 18: ...ct application of the sensor Placement of the sensor on an extremity with a blood pressure cuff arterial catheter or intravascular line User s moving 5 Specifications 5 1 Parameters SpO2 Display range...

Page 19: ...width height 5 5 Automatic storage Total storage time 30 h Frequency the interval between two records is 1s Note Data is saved automatically when the oximeter is started If the register of the oximet...

Page 20: ...wer off automatically Probe off indication when the probe is not connected to the unit the following indication picture will appear Refer to Pic 11 No finger indication when the probe is connected to...

Page 21: ...to store and read data but can enter into normal state E13 Low battery voltage Note Please DO NOT repair or disassemble the unit when the error code appears Please contact to our service department i...

Page 22: ...to dry thoroughly before reusing 4 Store the wrist oximeter within the stated environmental specifications See Specifications for additional information 9 Warranty and Repair 9 1 Service Method 1 Ser...

Page 23: ...install replace the parts of the oximeter The damage and failure caused by user or its representative doesn t comply with the operator s manual 3 The oximeter is installed or connected with such exter...

Page 24: ...damages and failures Any product of any other manufacturer 9 5 User s Special Request for Guarantee Time Our guarantee constitution for oximeter complies with electronic product after sale service st...

Page 25: ...The customer is responsible for any freight insurance charges for returned product 9 6 Repackage Take all the accessories and put them into plastic cover Try to use original package and packing mater...

Page 26: ...PR11 Group 1 The MD300W11 pulse oximeter uses RF energy only for its internal function Therefore its PR emissions are very low and are not likely to cause any interference in nearby electronic equipme...

Page 27: ...C 61000 4 8 3A m 3A m Guidance and manufacture s declaration electromagnetic immunity For EQUIPMENT and SYSTEMS that are not LIFE SUPPORTING Guidance and manufacture s declaration electromagnetic immu...

Page 28: ...n the compliance level in each frequency range b NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is...

Page 29: ...r can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the MD300w11 pulse oximeter as recommended be...

Page 30: ...mitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is...

Page 31: ...V1 0W11 WRIST PULSE OXIMETER 31 Pic 4 Pic 5...