Figure 12 Schematic diagram of electrical connection 

 

note 

 

If one set of arrays is connected to another with the 

opposite  polarity,  it  will  cause  irreparable  damage 

to  the  product.  Before  connecting  in  parallel,  be 

sure  to  confirm  the  voltage  and  polarity  of  each 

column.  If  the  measurement  finds  that  the  polarity 

between  the  columns  is  reversed  or  the  voltage 

difference is greater than 10V,  you  must check the 

structure  and  configuration  before  making  the 

connection. 

 

The  number  of  photovoltaic  modules  in  series  and 

parallel  must  be  designed  reasonably  according  to 

the system configuration. 

 

Photovoltaic  modules  of  different  electrical 

performance  models  cannot  be  connected  in  a 

string. 

 

Special solar cables and connectors should be used 

in  the  system,  and  all  connections  should  be 

securely tightened. The cable size should be 4mm2 

(12  AWG)  and  must  be  able  to  withstand  the 

maximum  open  circuit  voltage  of  the  photovoltaic 

system. 

 

When  the  cable  is  fixed  on  the  bracket,  it  is 

necessary to avoid mechanical damage to the cable 

or photovoltaic module, and do not press the cable 

with force. To fix the cable through the proper way, 

a  specially  designed  tying  coil  and  wire  clip  must 

be  used  to  fix  it  on  the  bracket.  Avoid  direct 

sunlight and water soaking cables. 

 

Please keep the connector dry and clean, and make 

sure  that  the  nut  of  the  connector  is  tightened 

before  connecting.  Do  not  connect  the  connector 

when it is found that the connector is wet, dirty, or 

in  other  bad  conditions.  Avoid  direct  sunlight  and 

immersion  of  the  connector  in  water.  Avoid  the 

connector falling on the ground or roof. 

 

When  the  photovoltaic  module  is  in  a  live  state, 

Summary of Contents for ASTRONERGY CHSM54M-HC

Page 1: ...1 Crystalline Silicon PV Module Installation Manual Rev1 2 Released in August 2021 ...

Page 2: ...l safety measures 5 4 Handling and unpacking 7 4 1 Transport 8 4 2 Unpack 8 5 Mechanical installation 9 5 1 Installation conditions 9 5 2 Installation angle selection 10 5 3 Installation Method 10 6 Electrical Installation 15 6 1 Electrical properties 15 6 2 Electrical connection 16 6 3 Grounded 18 7 Maintenance 19 7 1 Routine inspection 19 Modified version and date 20 ...

Page 3: ...SM6610M CHSM6610M BL CHSM6610M HV CHSM60M HC CHSM60M BL H C CHSM6610P CHSM6610P HV CHSM60P HC CHSM6612M CHSM6612M HV CHSM72M HC CHSM60M LV HC CHSM6612P CHSM6612P HV CHSM72P HC CHSM72M LV H C CHSM54M HC CHSM54M BL H C 1 2 Limitation of Liability Since the use of this manual and the installation operation use and maintenance of photovoltaic modules are beyond the control of Chint Solar this manual d...

Page 4: ...he relevant local authority to determine the installation permit and installation inspection requirements that meet the local requirements The installation process should comply with the safety rules applicable to all components in the system including cables terminals charging monitors batteries inverters etc If you install or operate photovoltaic modules on a rainy day or in the morning with dew...

Page 5: ... from the photovoltaic module The cover of the junction box should always be kept closed Avoid partial shading of photovoltaic modules for a long time Otherwise the temperature of the shaded solar cells will rise hot spot effect and in severe cases the photovoltaic modules may be burned or even a fire may occur For photovoltaic modules used in deserts or windy and sandy areas it is recommended to ...

Page 6: ...s When the photovoltaic modules are electrically connected choose a dry and weak morning or evening or use opaque materials to completely cover the surface of the photovoltaic modules to prevent current generation A certain distance between the photovoltaic module and the installation surface should be kept to prevent the installation surface from touching the junction box When installing on the r...

Page 7: ...t damage the surrounding photovoltaic modules or their support structures When cleaning photovoltaic modules you must follow the cleaning requirements of photovoltaic modules The connectors must be kept dry and clean to ensure that they are in good working condition Do not insert other metal objects into the connector or make electrical connections in any other way 4 Handling and unpacking If the ...

Page 8: ... the frame with both hands in the same direction to take out the photovoltaic module one piece time and remove the photovoltaic module by tearing off a piece of fixing glue The photovoltaic modules in the box are dumped if the internal packaging is fixed by the internal packing belt first cut the internal packing belt use anti inverted sticks and other non sharp and reliable items to hold one side...

Page 9: ...n 5 1 Installation conditions Recommended ambient temperature 20 C to 50 C extreme working environment temperature of photovoltaic modules 40 C to 85 C Photovoltaic module mechanical load Under standard installation conditions the maximum test snow wind load is 5400Pa 2400Pa and the design load considering a safety factor of 1 5 is 3600Pa 1600Pa For specific installation methods and mechanical loa...

Page 10: ...angle PV modules connected in series should be installed in the same orientation and angle If the orientation and angle are different the solar radiation received by each module may be different resulting in power loss 5 3 Installation Method The photovoltaic module mounting bracket must be made of durable corrosion resistant and UV resistant materials The mounting bracket must be inspected and te...

Page 11: ...g 4 Outer four hole bolt installation for 72cell Fig 5 Internal four hole bolt installation for 72cell Fig 6 400mm pitch bolt installation for 72cell note In order to achieve maximum safety precautions against wind and snow loads it is recommended that all available mounting holes should be used Bolts are inserted as described in the process below Sketch figure 7 Figure 7 Schematic diagram of bolt...

Page 12: ...must be longer than the length of module frame otherwise please confirm with our product team to get approval The above two diagrams show the installation method using aluminum clamps also called fixtures D indicates the allowable installation range of the aluminum press block Please refer to 4 3 3 for the specific recommended installation location and corresponding load indicates that the photovo...

Page 13: ... the side clamps for reference Suggest the dimensions for middle clamps are a 40mm b 26mm c 5mm d 28mm and Ø 9mm The torque for tightening the nut and bolts are recommended 17 23Nm when the property class of bolts and screws is Class 8 8 Figure 10 Schematic diagram of intermediate pressing block Figure 11 Schematic diagram of side pressing block For the installation method shown in Figure 9 the mo...

Page 14: ...LV HC 1666 992 35 5400Pa 2400Pa 5400 2400Pa Installation scope 207 408mm 2400 2400Pa Installation scope 50 200mm 1675 992 35 5400Pa 2400Pa 5400 2400Pa Installation scope 215 415mm 2400 2400Pa Installation scope 50 200mm 1692 1002 35 5400Pa 2400Pa 5400 2400Pa Installation scope 350 50mm 2400 2400Pa Installation scope 50 200mm 1755 1038 35 1765 1048 35 5400Pa 2400Pa 5400 2400Pa Installation scope 40...

Page 15: ...a 2400Pa 2400Pa 2400Pa 5400 2400Pa Installation scope 350 50mm 2400Pa 2400Pa Bumper 2108 1048 35 2094 1038 35 5400Pa 2400Pa 2400Pa 2400Pa 5400 2400Pa Installation scope 400 50mm 2400Pa 2400Pa Bumper 2256 1133 35 5400Pa 2400Pa 2400Pa 2400Pa 5400 2400Pa Installation scope 400 450mm 1800Pa 1800Pa Bumper 6 Electrical Installation 6 1 Electrical properties For details of the electrical performance para...

Page 16: ...the PV output Refer to Section 690 8 of the National Electrical Code for an additional multiplying factor of 125 80 derating which may be applicable That means when determining the voltage rating conductor capacity fuse rating and photovoltaic output control size the parameters need to be multiplied by the square of 1 25 According to the max fusing rate of modules and local electical installation ...

Page 17: ...ectors should be used in the system and all connections should be securely tightened The cable size should be 4mm2 12 AWG and must be able to withstand the maximum open circuit voltage of the photovoltaic system When the cable is fixed on the bracket it is necessary to avoid mechanical damage to the cable or photovoltaic module and do not press the cable with force To fix the cable through the pro...

Page 18: ...uspect or find that the diode is malfunctioning please contact Chint please do not try to open the junction box cover by yourself 6 3 Grounded Chint Solar modules use an anodic oxidized aluminum frame to resist corrosion So the frame of modules should be connected to the equipment grounding conductor to prevent thunder and electrical shock The grounding device should fully contact with the inside ...

Page 19: ...otovoltaic modules in the photovoltaic array are damaged such as glass breakage cable breakage junction box damage cell damage backplane breakage and other factors that lead to functional and safety failures of photovoltaic modules When the above problems occur the supplier must be notified in time to replace the same type of photovoltaic modules It is recommended to perform a preventive inspectio...

Page 20: ... bristles to clean the surface of the photovoltaic module For more detailed instructions related to cleaning and maintenance please refer to the Photovoltaic Module Cleaning Manual Modified version and date Rev1 0 released in June 2018 Rev1 2 released in August 2021 ...

Page 21: ...21 CHINT SOLAR ZHEJIANG Co Ltd Add 1335 Bin an Rd Binjiang District Hangzhou China 310053 Tel 86 571 5603 1888 Fax 86 571 5603 2333 http energy chint com ...

Reviews: