65
(1) The inverter can be started and shut down with “1 ON/OFF” menu.
Move the cursor to “ON” and press
ENT
, “ON State” will then be indicated at
the bottom of LCD screen; move the cursor to “OFF” and press
ENT
, then
“OFF State” will be indicated as well. The inverter will stand by instead of
working normally if the startup conditions do not meet the set value even if
“ON”
is selected. The inverter will be shut down immediately if “OFF” is selected in
any case.
(2) Five languages, i.e. Chinese, French, English, German, and Italian are
available in “2 Language” menu.
(3) Key beep and Alarm
beep can be set mute/unmute in “3 Buzzer” menu.
“Key beep” and “Alarm beep” can be chosen by pressing
UP
and
DOWN
. Shift
between “Enable” and “Disable” by pressing
UP
and
DOWN
if the cursor is on
the “Key beep”. Complete the setup by pressing
ENT
. Similarly, the Alarm
beep can be set up in the same way.
(4) Set up the system date and time with “4 SysTime” menu (These
parameters are of critical importance and will be used in history information).
(5) Set the 485 communication parameters with “5 Commun.” menu.
(6) There are 5 submenus i
n the “6 MPPTScan” menu:
1.
“ARCOption” is used to enable/disable the ARC function. Press ENT
and use
UP
and
DOWN
to enable/disable the ARC function, and press ENT to
confirm the setting.
2.
“ARCFaultClear” is used to clear the ARC fault. Move the cursor to this
menu, and press
ENT
. The operation result will appear on the LCD, ie.
“Succeed” or “Failed”.
3.
“MPPTOption” is used to enable the MPPT Scan. Move the cursor to
this menu, press
ENT
to set up the function. Use
UP
and
DOWN
to
enable/disable the
“MPPTOption” function. Press
ENT
to confirm the setting.