background image

RMT2/RLT2/RXT2

Installation Instructions

6

TOOLS REQUIRED FOR INSTALLATION

PARTS

          7/32" (5.5mm)

#2

1/2" (12.7mm)

5/16" (7.9mm)

GC(6)

M4 x 25mm

GG(6)

M5 x25mm

GK(6)

M6 x 35mm

GN(6)

M8 x 40mm

1/2"(12.7mm)

A(1)

[wall plate]

B(1)

[left upright]

GA(8)

M4 x 16mm

GB(6)

M4 x 20mm

GD(6)

M4 x 35mm

GE(6)

M5 x16mm

GF(6)

M5 x20mm

GI(6)

M6 x16mm

GJ(6)

M6 x 25mm

GL(6)

M8 x 20mm

GM(6)

M8 x 30mm

GO(6)

M8 x 50mm

GP(8)

1/4"(6.4mm)

GQ(8)

GS(8)

[universal washer]

D(4 or 6)

   5/16 x 2 1/2"

E(4 or 6)

        5/16"

F(4 or 6)

  [concrete anchor]

C(1)

[right upright]

For below kit, quantities
are 4 for RMT2 and RLT2,
6 for RXT2.

(RXT2 shown)

GH(6)

M5 x 35mm

G(1)

Hardware Bag

Summary of Contents for RLT2

Page 1: ...de Instalação Istruzioni di installazione Installatie instructies Instructions d installation RMT2 RLT2 RXT2 Universal Tilt Mounts Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description RMT2 RLT2 RXT2 ...

Page 2: ...ty to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Rein...

Page 3: ... TO BOTTOM OF WALL PLATE OPENING 22 00 34 1 00 8 38 11 00 16 00 5 19 11 49 1 96 TILTS BACK 5 4 CABLE ACCESS WHEN KICKSTAND IS ACTIVATED 12 MAX TILT 16 50 15 75 MAX 28 69 7 87 TOP MOUNTING HOLE TO CENTERLINE NOTCH ON WALL PLATE 7 00 WALL OPENING 30 75 34 1 00 8 38 15 38 16 00 5 19 24 00 2 50 CENTERLINE TO BOTTOM OF WALL PLATE OPENING 11 49 1 96 TILTS BACK 5 CABLE ACCESS WHEN KICKSTAND 12 ...

Page 4: ...IONS RXT2 7 00 WALL OPENING 38 00 1 00 8 38 34 19 68 MAX 35 94 19 00 16 00 5 19 24 00 32 00 9 84 TOP MOUNTING HOLE TO CENTERLINE NOTCH ON WALL PLATE 11 49 2 50 CENTERLINE TO BOTTOM OF WALL PLATE OPENING 1 96 TILTS BACK 5 CABLE ACCESS WHEN KICKSTAND 12 ...

Page 5: ...el Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche By Hand A mano Von Hand Com a mão A mano Met de hand À la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perfo...

Page 6: ...l plate B 1 left upright GA 8 M4 x 16mm GB 6 M4 x 20mm GD 6 M4 x 35mm GE 6 M5 x16mm GF 6 M5 x20mm GI 6 M6 x16mm GJ 6 M6 x 25mm GL 6 M8 x 20mm GM 6 M8 x 30mm GO 6 M8 x 50mm GP 8 1 4 6 4mm GQ 8 GS 8 universal washer D 4 or 6 5 16 x 2 1 2 E 4 or 6 5 16 F 4 or 6 concrete anchor C 1 right upright For below kit quantities are 4 for RMT2 and RLT2 6 for RXT2 RXT2 shown GH 6 M5 x 35mm G 1 Hardware Bag ...

Page 7: ...Figure 1 Figure 1 2 Level wall plate A and mark locations of pilot holes See Figure 2 NOTE The RMT2 must be installed on two 16 studs The RLT2 can be installed on 16 studs inner holes or 24 studs outer holes For the RXT2 it can be mounted over two or three 16 studs or two 24 studs If mounting to three 16 studs it must be mounted to all three studs using the outer holes and center holes See Figure ...

Page 8: ...repare it for mounting to wall See Figure 1 2 Level wall plate A and mark locations of pilot holes at desired mounting location See Figure 5 IMPORTANT The RMT2 RLT2 RXT2 mounts are designed to be mounted to an 8 concrete or 8 x8 x16 concrete block wall NOTE For the RLT2 either the inner or outer four holes may be used NOTE For the RXT2 use the outer four holes and the two middle holes on wall plat...

Page 9: ...nsert SHORTEST length screw of selected diameter GA GE GI or GL through bracket B or C universal washer GS selected spacer GP or GQ if required into display mounting hole Do NOT thread screw into hole at this time Proper screw length requires base of screw head to protrude above flat washer a distance equal to or greater than the screw diameter If screw length is inadequate select longer screw Sel...

Page 10: ...erface brackets are in the kickstand position by pulling down on handles as far as possible See Figure 10 2 Hang display with brackets B and C on upper rail of wall plate A Kickstand should be engaged with lower portion of wall plate See Figure 10 Figure 10 NOTE Any cable management or rear display adjustments should be made when the display is resting on the kickstand 3 Unlock kickstand by pushin...

Page 11: ...on the other side 2 Replace the knob washer and screw in the opposite order See Figure 11 Figure 11 3 Repeat for the other interface bracket 4 Install interface brackets according to instructions in Install Brackets to Display section Tilt Adjustment 1 Adjust tilt tension adjustment knobs to desired tension See Figure 12 2 Adjust tilt of display by pulling the top of display away from the wall unt...

Page 12: ...P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 RMT2 RLT2 RXT2 Installation Instructions Chief Manufacturing a products divi sion of Milestone AV Technologies 8800 002428 Rev00 2013 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 11 13 ...

Reviews: