Installation Instructions

PAC527 Series

9

3.

Wire the outlet box(es) as required. Refer to Table 1 and
Table 2 for input and output specifications. (See Figure 2)

Table 1: Input Specifications

Table 2: Output Specifications

CAUTION:

Isolated ground-mounting means NOT

grounded. Grounding wire connection required.

IMPORTANT ! :

If a separate isolated green/yellow

ground wire is installed in the building wiring, attach it
separately to the green/yellow isolated ground wire on

box. If there is no separate green/yellow isolated ground
wire, connect green ground wire to both green/yellow

isolated ground wire and green box ground wire on box.

NOTE:

The grounding conductors serving this outlet are to be
connected to earth ground at the service equipment or
other acceptable building earth ground such as the
building frame in the case of a high-rise steel-frame
structure. Connections should be made with minimum
AWG 14 copper wire intended for use on a 15 Amp
circuit. The conductors used to connect the outlet to the
line or bus and ground shall not be any longer than
necessary and shall avoid unnecessary bends.

NOTE:

An insulated grounding conductor that is identical in

size and insulation material and thickness to the
grounded and ungrounded circuit supply conductors,
except that it is green with or without one or more
yellow stripes, is to be installed as part of the circuit that
supplies the outlet. Refer to Table 250-122 of the
National Electrical Code regarding the appropriate size
of the grounding conductor.

NOTE:

Pressure terminal or pressure splicing connectors and
soldering lugs used in the installation of the outlet shall
be identified as being suitable for the material of the
conductors. Conductors of dissimilar metals shall not
be intermixed in a terminal or splicing connector where
physical contact occurs between dissimilar conductors
unless the device is identified for the purpose and
conditions of use.

Figure 2

4.

Replace the power kit in the PAC527, fitting the two slots in
the power kit lower tab around two fasteners in the PAC527.
(See Figure 1) and (See Figure 2)

5.

Tighten three Phillips screws to secure power kit in the
PAC527. (See Figure 2)

Outlet Box Use

NOTE:

The "PROTECTED" light indicates that the surge

protection circuitry is active and operational.

Figure 3

Input

Input voltage, frequency

125 V AC, 60 Hz

Input connection type

4x14 AWG stranded, UL Style
1015, CSA TEW

Input Wire colors

Black - Line

White - Neutral

Green - Box Ground

Green/Yellow - Isolated Ground

Input wire length (ft.)

1 (with a 3/4" stripped end)

Output

Output

15 A, 1875 W

Power consumption

<0.5 watt

Fuses

Thermal current interrupting circuits
are in MOVs

Quantity/Type

Duplex NEMA 5-15R Isolated Ground
Receptacle

Color/Markings

Grey with protection symbol (Orange
triangle)

4

    GREEN

(box ground)

5

x 3

       (PAC527FxP4
  shown as example)

 WHITE

(neutral)

 BLACK

   (line)

    GREEN/YELLOW

     (isolated ground)

Lower tab
on power kit

"PROTECTED"

indicator light

(PAC527FxP4
shown as example)

Summary of Contents for PAC527 Series

Page 1: ...PDF provided by Conference Room AV Chief PAC527FBP6 XL In Wall Storage Box with 6 Receptacle Filter and Surge ...

Page 2: ...I N S T A L L A T I O N I N S T R U C T I O N S PAC527 PAC527F PAC527FC PAC527FxP4 PAC527FxP6 PAC527F KIT PAC527CVR KIT PACPL1 In Wall Box and Accessories PAC527 Series ...

Page 3: ...ombined weight of all equipment Reinforce the structure as required before installing the accessory WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located in the accessory does not exceed 40 lbs 18 1 kg Each PAC527 may hold up to 4 individual backplanes 2 comp...

Page 4: ...Make sure the outlet is properly grounded See grounding instructions CAUTION This equipment must be installed and assembled by qualified service personnel in accordance with local building and electrical codes NOTE Knockouts are provided for ease of installation Any unused knockouts that have been punched are to be closed up with a metal plug Ambient Temperature The manufacturer s maximum ambient ...

Page 5: ...el Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche By Hand A mano Von Hand Com a mão A mano Met de hand À la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perfo...

Page 6: ...4 OPTIONAL E 1 PAC527 F 1 Template A 4 1 4 x 2 1 2 C 8 06 x 3 8 B 8 06 32 D 4 3 8 Temporary Cover G 1 PAC527F F 1 Template A 4 1 4 x 2 1 2 C 8 06 x 3 8 B 8 06 32 D 4 3 8 Temporary Cover H 1 PAC527FC F 1 Template A 4 1 4 x 2 1 2 C 8 06 x 3 8 B 8 06 32 D 4 3 8 Temporary Cover PAC527 PAC527F PAC527FC ...

Page 7: ...8 Temporary Cover PAC527FxP4 K 1 PAC527FxP6 F 1 Template A 4 1 4 x 2 1 2 C 8 06 x 3 8 B 8 06 32 D 4 3 8 Temporary Cover PAC527FxP6 L 1 Flange F 1 Template M 8 10 24 x 1 4 Temporary Cover PAC527F KIT N 1 Cover PAC527CVR KIT P 2 06 x 1 1 4 Q 2 06 x 1 1 2 S 2 259 x 156 x 625 T 2 06 R 1 1 8 security PACPL1 U 2 Backplane V 8 10 24 x 3 8 ...

Page 8: ...posed The wall then must be finished around the opening of the box after the box has been installed Locating PAC527 1 Identify a suitable wall location for the accessory 2 Locate and mark studs using a stud sensor 3 Identify possible structural conflicts electrical wiring plumbing gas lines HVAC WARNING ELECTRICAL SHOCK HAZARD CUTTING OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR ...

Page 9: ...on to the panel board grounding terminal bar as permitted in 408 40 Exception so as to terminate within the same building or structure directly at an equipment grounding conductor terminal of the applicable derived system or service Where installed in accordance with the provisions of this section this equipment grounding conductor shall also be permitted to pass through boxes wire ways or other e...

Page 10: ...t that supplies the outlet Refer to Table 250 122 of the National Electrical Code regarding the appropriate size of the grounding conductor NOTE Pressure terminal or pressure splicing connectors and soldering lugs used in the installation of the outlet shall be identified as being suitable for the material of the conductors Conductors of dissimilar metals shall not be intermixed in a terminal or s...

Page 11: ...ing a utility knife and remove drywall 5 Check stud depth within the wall If 3 1 2 or greater proceed to PAC527 Box Preparation and Installation If less than 3 1 2 deep proceed to Step 6 6 If present remove box flange by loosening screws See Figure 5 CAUTION Injury may occur on sharp edges Carefully discard the removable tabs Avoid sharp edges 7 Snap off removable tabs at perforations provided 8 R...

Page 12: ...AC527 into studs through mounting holes in PAC527 Wood studs use 3 16 drill bit Steel studs use 1 4 drill bit 5 Install PAC527 to studs using four 1 4 x 2 1 2 Phillips flat head screws A and four 3 8 flat washers D through PAC527 and pilot holes See Figure 8 Figure 8 NOTE If installing in a stud wall BEFORE the drywall is installed remove outer flange from PAC527 before installing the PAC527 See F...

Page 13: ...lowing component manufacturer s instructions 4 PACPL1 ONLY Loosely install two 10 24 x 3 8 Phillips external tooth screws V into each backplane half See Figure 11 5 Reinstall backplanes directly under tabs located at any of the three levels in the PAC527 6 Fasten in place using Phillips screws loosened in Step 1 OR Phillips screws V installed in Step 4 See Figure 11 NOTE Each individual section of...

Page 14: ...ws and tighten screws See Figure 15 Figure 15 PAC527CVR KIT 1 Break away the tab s on the cover N to allow wire exit from the PAC527 and to meet ventilation needs of the components See Figure 16 Figure 16 2 Gather all wires and route through the cover opening s See Figure 17 3 Install cover N and fasten with two 6 x 1 1 4 Phillips self tapping screws P 6 x 1 1 2 button head self tapping screws Q f...

Page 15: ... 8 10 00 254 0 5 00 127 0 0 50 12 7 TYPICAL 1 50 38 1 TYPICAL 1 25 31 8 TYPICAL 0 20 5 2 X 0 95 24 2 1 00 25 4 FINGER HOLD BREAK OFF LINE NOTE SCREWS ARE THREADED TO THE BACKPLANE 1 TWO PIECES ONE PIECE SHOWN ABOVE 2 INCLUDED WITH ENCLOSURE PAC527 DIMENSIONS INCHES MILLIMETERS ...

Page 16: ... 304 8 10 00 254 0 5 00 127 0 0 50 12 7 TYPICAL 1 50 38 1 TYPICAL 1 25 31 8 TYPICAL 0 20 5 2 X 0 95 24 2 1 00 25 4 FINGER HOLD BREAK OFF LINE NOTE SCREWS ARE THREADED TO THE BACKPLANE 1 TWO PIECES ONE PIECE SHOWN ABOVE 2 INCLUDED WITH ENCLOSURE PAC527F DIMENSIONS INCHES MILLIMETERS ...

Page 17: ...0 127 0 THREE BACKPLANE DEPTH POSITIONS AVAILABLE 3 88 98 4 2 88 73 0 1 73 44 0 2 00 50 8 0 34 8 6 MOUNTING HOLE KNOCKOUT 11 00 279 4 20 00 508 0 BREAK OFF REGION FOR 2 1 2 WALL INSTALLATION 2 38 60 3 2 38 60 3 2 00 50 8 3 63 92 1 2 00 50 8 3 63 92 1 1 37 34 8 A B RECOMMENDED ELECTRICAL BOX RACO 560 3 X 2 BOX 2 3 4 DEEP GANGABLE OR EQUIVALENT RECOMMENDED ELECTRICAL BOX COVER RACO 864 SINGLE DUPLEX...

Page 18: ...3 13 90 353 0 USEABLE STORAGE SPACE 15 40 391 1 22 18 563 4 3 88 98 4 23 26 590 9 0 09 2 4 SEE PAC527F FOR ADDITIONAL BOX DIMENSIONS AC LINE POWER CONDITIONER 125 V 60 Hz 15 A 4x14 AWG STRANDED WIRE W ISOLATED GROUND SURGE PROTECTION EMI RFI FILTERING POWER CONSUMPTION 0 5 WATT PAC527FxPx DIMENSIONS INCHES MILLIMETERS ...

Page 19: ...NSIONS continued 23 26 590 9 15 40 391 1 13 90 353 0 21 76 552 8 4 75 120 7 0 43 11 0 PAC527F KIT DIMENSIONS INCHES MILLIMETERS 13 38 339 7 13 81 350 8 21 75 552 5 1 50 38 0 5 00 127 0 3 63 92 1 0 69 17 5 PAC527CVR KIT DIMENSIONS INCHES MILLIMETERS ...

Page 20: ...00 304 8 10 00 254 0 5 00 127 0 0 50 12 7 TYPICAL 1 50 38 1 TYPICAL 1 25 31 8 TYPICAL 1 00 25 4 FINGER HOLD 0 95 24 2 0 20 5 2 BREAK OFF LINE NOTE SCREWS ARE THREADED TO THE BACKPLANE 1 PACPL1 KIT INCLUDES TWO BACK PLANE PIECES AS 2 SHOWN ABOVE PACPL1 DIMENSIONS INCHES MILLIMETERS ...

Page 21: ...94 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 Chief a products division of Milestone AV Technologies 8800 002967 Rev01 2017 Milestone AV Technologies www milestone com 09 17 ...

Reviews: