background image

PAC527 Series

Installation Instructions

2

DISCLAIMER

Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively “Milestone”), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.

Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.

DEFINITIONS

MOUNTING SYSTEM:

A MOUNTING SYSTEM is the

primary Chief product to which an accessory and/or component

is attached.

ACCESSORY:

AN ACCESSORY is the secondary Chief

product which is attached to a primary Chief product, and may

have a component attached or setting on it.

COMPONENT:

A COMPONENT is an audiovisual item

designed to be attached or resting on an accessory or mounting
system such as a video camera, CPU, screen, display,
projector, etc.

WARNING:

A WARNING alerts you to the possibility of

serious injury or death if you do not follow the instructions.

CAUTION:

A CAUTION alerts you to the possibility of

damage or destruction of equipment if you do not follow the
corresponding instructions.

 IMPORTANT SAFETY INSTRUCTIONS

WARNING:

Failure to read, thoroughly understand, and

follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all accessories are
properly assembled and installed using the instructions
provided.

WARNING:

Failure to provide adequate structural strength

for this accessory can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this accessory is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
accessory.

WARNING:

Exceeding the weight capacity can result in

serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components located in the accessory does not exceed
40 lbs (18.1 kg).

Each PAC527 may hold up to 4 individual backplanes
(2 complete) and each individual backplane may hold a
maximum weight of 10 lbs (4.5 kg)

A half backplane (after separation) may hold a
maximum weight of 5 lbs (2.3 kg).

WARNING:

Use this accessory only for its intended use as

described in these instructions. Do not use attachments not
recommended by the manufacturer.

WARNING:

Never operate this accessory if it is damaged.

Return the accessory to a service center for examination and
repair.

WARNING:

For indoor use only.

IMPORTANT ! :

The PAC527 accessory is designed to be

mounted to either a 2" x 3" or 2" x 4" wood stud wall 16" on
center, or a 2" x 3"-25ga (minimum) or 2" x 4"-25ga (minimum)
steel studs wall.

NOTE:

Spacings - Minimum spacings between the 120 Vac

power components and the A/V components shall be
maintained for safe operation of the equipment when
installed in accordance with the National Electric Code,
ANSI/NFPA 70.

NOTE:

When selecting a Listed 120 Vac Receptacle for use as

the main power source for the PAC series boxes (to
power the A/V equipment), make sure that AC
Receptacle is rated at least 15A and it is used in the
building’s AC branch circuit that is connected to a
circuit breaker rated at least 15A. Do not connect more
than 12A from the Receptacle.

In the U.S., the equipment shall be installed per the applicable
requirements of the National Electrical Code, CSA C22.1.

In Canada, the equipment shall be installed per the applicable
requirements of the National Electrical Code, ANS/NFPA 70.

NOTE:

It is the installer’s responsibility to ensure that the

enclosure is bonded to the ground in the switch box, in
accordance with the National Electric Code, ANSI/NFPA
70 or Canadian Electrical Code, CSA C22.1. A green
grounding screw is provided in the enclosure for the
purpose, if required.

IMPORTANT ! :

The PAC527 mounts are designed to

accommodate the following Chief power kits ONLY:

PAC527P4-KIT

PAC527P6-KIT

--SAVE THESE INSTRUCTIONS--

DIMENSION DRAWINGS

are located at the end of these

Installation Instructions.

Summary of Contents for PAC527 Series

Page 1: ...PDF provided by Conference Room AV Chief PAC527FBP6 XL In Wall Storage Box with 6 Receptacle Filter and Surge ...

Page 2: ...I N S T A L L A T I O N I N S T R U C T I O N S PAC527 PAC527F PAC527FC PAC527FxP4 PAC527FxP6 PAC527F KIT PAC527CVR KIT PACPL1 In Wall Box and Accessories PAC527 Series ...

Page 3: ...ombined weight of all equipment Reinforce the structure as required before installing the accessory WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located in the accessory does not exceed 40 lbs 18 1 kg Each PAC527 may hold up to 4 individual backplanes 2 comp...

Page 4: ...Make sure the outlet is properly grounded See grounding instructions CAUTION This equipment must be installed and assembled by qualified service personnel in accordance with local building and electrical codes NOTE Knockouts are provided for ease of installation Any unused knockouts that have been punched are to be closed up with a metal plug Ambient Temperature The manufacturer s maximum ambient ...

Page 5: ...el Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche By Hand A mano Von Hand Com a mão A mano Met de hand À la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perfo...

Page 6: ...4 OPTIONAL E 1 PAC527 F 1 Template A 4 1 4 x 2 1 2 C 8 06 x 3 8 B 8 06 32 D 4 3 8 Temporary Cover G 1 PAC527F F 1 Template A 4 1 4 x 2 1 2 C 8 06 x 3 8 B 8 06 32 D 4 3 8 Temporary Cover H 1 PAC527FC F 1 Template A 4 1 4 x 2 1 2 C 8 06 x 3 8 B 8 06 32 D 4 3 8 Temporary Cover PAC527 PAC527F PAC527FC ...

Page 7: ...8 Temporary Cover PAC527FxP4 K 1 PAC527FxP6 F 1 Template A 4 1 4 x 2 1 2 C 8 06 x 3 8 B 8 06 32 D 4 3 8 Temporary Cover PAC527FxP6 L 1 Flange F 1 Template M 8 10 24 x 1 4 Temporary Cover PAC527F KIT N 1 Cover PAC527CVR KIT P 2 06 x 1 1 4 Q 2 06 x 1 1 2 S 2 259 x 156 x 625 T 2 06 R 1 1 8 security PACPL1 U 2 Backplane V 8 10 24 x 3 8 ...

Page 8: ...posed The wall then must be finished around the opening of the box after the box has been installed Locating PAC527 1 Identify a suitable wall location for the accessory 2 Locate and mark studs using a stud sensor 3 Identify possible structural conflicts electrical wiring plumbing gas lines HVAC WARNING ELECTRICAL SHOCK HAZARD CUTTING OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR ...

Page 9: ...on to the panel board grounding terminal bar as permitted in 408 40 Exception so as to terminate within the same building or structure directly at an equipment grounding conductor terminal of the applicable derived system or service Where installed in accordance with the provisions of this section this equipment grounding conductor shall also be permitted to pass through boxes wire ways or other e...

Page 10: ...t that supplies the outlet Refer to Table 250 122 of the National Electrical Code regarding the appropriate size of the grounding conductor NOTE Pressure terminal or pressure splicing connectors and soldering lugs used in the installation of the outlet shall be identified as being suitable for the material of the conductors Conductors of dissimilar metals shall not be intermixed in a terminal or s...

Page 11: ...ing a utility knife and remove drywall 5 Check stud depth within the wall If 3 1 2 or greater proceed to PAC527 Box Preparation and Installation If less than 3 1 2 deep proceed to Step 6 6 If present remove box flange by loosening screws See Figure 5 CAUTION Injury may occur on sharp edges Carefully discard the removable tabs Avoid sharp edges 7 Snap off removable tabs at perforations provided 8 R...

Page 12: ...AC527 into studs through mounting holes in PAC527 Wood studs use 3 16 drill bit Steel studs use 1 4 drill bit 5 Install PAC527 to studs using four 1 4 x 2 1 2 Phillips flat head screws A and four 3 8 flat washers D through PAC527 and pilot holes See Figure 8 Figure 8 NOTE If installing in a stud wall BEFORE the drywall is installed remove outer flange from PAC527 before installing the PAC527 See F...

Page 13: ...lowing component manufacturer s instructions 4 PACPL1 ONLY Loosely install two 10 24 x 3 8 Phillips external tooth screws V into each backplane half See Figure 11 5 Reinstall backplanes directly under tabs located at any of the three levels in the PAC527 6 Fasten in place using Phillips screws loosened in Step 1 OR Phillips screws V installed in Step 4 See Figure 11 NOTE Each individual section of...

Page 14: ...ws and tighten screws See Figure 15 Figure 15 PAC527CVR KIT 1 Break away the tab s on the cover N to allow wire exit from the PAC527 and to meet ventilation needs of the components See Figure 16 Figure 16 2 Gather all wires and route through the cover opening s See Figure 17 3 Install cover N and fasten with two 6 x 1 1 4 Phillips self tapping screws P 6 x 1 1 2 button head self tapping screws Q f...

Page 15: ... 8 10 00 254 0 5 00 127 0 0 50 12 7 TYPICAL 1 50 38 1 TYPICAL 1 25 31 8 TYPICAL 0 20 5 2 X 0 95 24 2 1 00 25 4 FINGER HOLD BREAK OFF LINE NOTE SCREWS ARE THREADED TO THE BACKPLANE 1 TWO PIECES ONE PIECE SHOWN ABOVE 2 INCLUDED WITH ENCLOSURE PAC527 DIMENSIONS INCHES MILLIMETERS ...

Page 16: ... 304 8 10 00 254 0 5 00 127 0 0 50 12 7 TYPICAL 1 50 38 1 TYPICAL 1 25 31 8 TYPICAL 0 20 5 2 X 0 95 24 2 1 00 25 4 FINGER HOLD BREAK OFF LINE NOTE SCREWS ARE THREADED TO THE BACKPLANE 1 TWO PIECES ONE PIECE SHOWN ABOVE 2 INCLUDED WITH ENCLOSURE PAC527F DIMENSIONS INCHES MILLIMETERS ...

Page 17: ...0 127 0 THREE BACKPLANE DEPTH POSITIONS AVAILABLE 3 88 98 4 2 88 73 0 1 73 44 0 2 00 50 8 0 34 8 6 MOUNTING HOLE KNOCKOUT 11 00 279 4 20 00 508 0 BREAK OFF REGION FOR 2 1 2 WALL INSTALLATION 2 38 60 3 2 38 60 3 2 00 50 8 3 63 92 1 2 00 50 8 3 63 92 1 1 37 34 8 A B RECOMMENDED ELECTRICAL BOX RACO 560 3 X 2 BOX 2 3 4 DEEP GANGABLE OR EQUIVALENT RECOMMENDED ELECTRICAL BOX COVER RACO 864 SINGLE DUPLEX...

Page 18: ...3 13 90 353 0 USEABLE STORAGE SPACE 15 40 391 1 22 18 563 4 3 88 98 4 23 26 590 9 0 09 2 4 SEE PAC527F FOR ADDITIONAL BOX DIMENSIONS AC LINE POWER CONDITIONER 125 V 60 Hz 15 A 4x14 AWG STRANDED WIRE W ISOLATED GROUND SURGE PROTECTION EMI RFI FILTERING POWER CONSUMPTION 0 5 WATT PAC527FxPx DIMENSIONS INCHES MILLIMETERS ...

Page 19: ...NSIONS continued 23 26 590 9 15 40 391 1 13 90 353 0 21 76 552 8 4 75 120 7 0 43 11 0 PAC527F KIT DIMENSIONS INCHES MILLIMETERS 13 38 339 7 13 81 350 8 21 75 552 5 1 50 38 0 5 00 127 0 3 63 92 1 0 69 17 5 PAC527CVR KIT DIMENSIONS INCHES MILLIMETERS ...

Page 20: ...00 304 8 10 00 254 0 5 00 127 0 0 50 12 7 TYPICAL 1 50 38 1 TYPICAL 1 25 31 8 TYPICAL 1 00 25 4 FINGER HOLD 0 95 24 2 0 20 5 2 BREAK OFF LINE NOTE SCREWS ARE THREADED TO THE BACKPLANE 1 PACPL1 KIT INCLUDES TWO BACK PLANE PIECES AS 2 SHOWN ABOVE PACPL1 DIMENSIONS INCHES MILLIMETERS ...

Page 21: ...94 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 Chief a products division of Milestone AV Technologies 8800 002967 Rev01 2017 Milestone AV Technologies www milestone com 09 17 ...