ISSUE 011

Installation Instructions

PSE90 Flat Screen Electric Wall Mount

Design Highlights

-Quiet Smooth Action with Variable Speed Motion
-Full Cable Management
-Stylish Look and Finish 
-Onboard Electronics
-Wide Range of Mounting Options

Thank you for choosing

future

automation

Summary of Contents for PSE90

Page 1: ...38 833565 ISSUE 011 InstallationInstructions PSE90FlatScreenElectricWallMount Design Highlights Quiet Smooth Action with Variable Speed Motion Full Cable Management Stylish Look and Finish Onboard Electronics Wide Range of Mounting Options Thank you for choosing futureautomation ...

Page 2: ... can result in serious personal injury or damage to equipment Future Sound Vision trading as Future Automation intend to make this and all documentation as accurate as possible However Future Automation makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of thi...

Page 3: ...ackage Contents 4 Stage 1 Screen Fitment 5 Before You Start Check 5 Stage 2 Vertical Height Alignment 6 Stage 3 Fitting The Mechanism To The Wall 7 Stage 4 Removing The Side Panel Cable Management 8 Stage 5 Mounting The Screen 9 Stage 6 Final Checks Set Up 10 Electrical Connections Contact Closure 11 RS232 12 Operation Details 12 Operations IR Control 13 IR Operation Buttons 13 Changing Batteries ...

Page 4: ...ed by misuse or damage accidental or otherwise or service modification by persons not authorised by Future Automation or the use of any non Future Automation supplied parts Any electrical or other environmental work external to your Future Automation mechanism including power cuts surges or lightning strikes Additional items not supplied by Future Automation although they may have been supplied to...

Page 5: ...Mechanism 1 1 Screen Mount Plate 1 2 Wall Mount Plate 1 3 Mechanism Cover 1 4 Link Arm 2 IR Remote Control Not Shown On Page 3 x2 AAA Batteries 4 Multi Pack Of Nut Bolts Washers 5 Mains Power Other Leads Your pack may also contain a custom adapter if your screen is not VESA compatible Nuts Bolts Multipack A range of nuts bolts washers and spacers to help add in the mounting for your screen ...

Page 6: ... suit your screen Further instructions relating to any custom mount will be included with the custom adapter When fitting the screen to the mechanism make sure that the centre of any adaptor plate is in line with the centre hole on the mechanism Screen fitment Before you start check the following The product is in good condition No damage to any parts Wiring is all secure The unit is in the closed...

Page 7: ...of 16 email info futureautomation co uk tel 44 0 1438 833577 fax 44 0 1438 833565 PSE90FlatScreenElectricWallMount Measure the distance from the top of the screen down to the top mounting hole on the wall plate From this measurement it is possible to determine where to drill the holes in the wall Remove screen from the mount before attaching the mechanism to the wall ...

Page 8: ...d at all times to ensure mechanism is always level It is the installers responsibility to choose the appropriate fixings when attaching to the wall and to make sure the mechanism is safe and secure Make sure the wall which the PSE90 is being mounted to is structurally suitable Step 1 Step 2 1 Fix the top 2 screws into the wall Keyhole details are 200mm apart symmetrical about screen centre 2 Hang ...

Page 9: ... cables through the mechanism Take off the side panel as shown by removing the 4 bolts 2 top and 2 bottom that hold it in place Replace side panels before using the PSE90 Cable management Now you can feed the cables through the inner tube along the lower strut and back down the outer tube Keep all the cables well secured Use as low profile cables as possible Disconnect the mains power before remov...

Page 10: ...eenElectricWallMount Attach the screen to the mounting plate using the appropriate fixings found in the fixtures pack It may be necessary with some screens to use spacers to provide clearance for AV cables at the rear Mounting the screen Mechanism with screen attached Make sure the mechanism is out when mounting the screen ...

Page 11: ...set options IN HOME PRESET A B C D E F OUT The PSE90 has standard preset positions linked to the buttons shown above The preset options are not active until the mechanism has gone fully OUT and IN If the mechanism is moving and the power is cut to revise ALL positions the mechanism needs to go back to the IN position after which the previously stored programmed positions will be retained Storing n...

Page 12: ...ED indicators 568A 568B 1 12V SUPPLY 12V SUPPLY CURRENT LIMITED W G W O 2 12V LATCH When 12V attached device will go OUT to PRESET position When 12V removed device will go IN G O 3 GROUND GROUND W O W G 4 DEVICE LATCH Short to GROUND pin 3 device will go OUT to PRESET position remove short device will go IN BL BL 5 PIN 4 NOT USED W BL W BL 6 DEVICE STOP Momentary short to GROUND pin 3 stops device...

Page 13: ...d positional counters Details Baud rate 9600 Stop bit 1 Parity None Databits 8 IMPORTANT Ensure protocol is entered exactly as written including Carriage Return Enter ASCII 13 After pressing STORE you have a 2 second window to select your save button after 2 seconds the command is void Mains Voltage Input IR LED IR Input Jack RS232 Contact Closure SLQV RS232 Use an RJ25 connector in the socket mar...

Page 14: ...racket fully out 90 to the wall In Brings the bracket fully in parallel to the wall Stop Will stop the operation at any position Preset Brings the bracket back out to the stored position Store and then Preset Stores the current location into the PSE90 memory PSE90FlatScreenElectricWallMount Operation buttons for the IR remote 1 Press IN before starting 2 Press STOP to stop at desired position 3 Th...

Page 15: ...8 833565 PSE90FlatScreenElectricWallMount Wall Mount PSE90 Trouble shooting For information on our products please refer to our web site www futureautomation co uk or for questions on installations and our product range please phone us on 44 0 1438 833577 and ask for our technical support department ...

Page 16: ...idth 1400mm 55 1 Control IR Remote RF Remote Contact Closure RS232 Power Supply 240V or 110V Control Of 3rd Party Product No Output Power Supply No Shipping Details Dimensions W D H 700x600x200mm 27 6x23 6x7 9 Weight Kg 25Kg 55 1lb A general technical overview of the PSE90 flat screen electric wall mount Technical overview Page 15 of 16 email info futureautomation co uk tel 44 0 1438 833577 fax 44...