Installation Instructions
IR10
7
OPERATIONS
Dry Contact Closures
The IR-10 provides dry contacts based on IR input.
Example: Pressing the ’UP’ button on the remote will cause a
connection to be made between COM and C1. This connection
can be used to trigger other devices (SL, Cinematic, or any third
party device that required this type of input).
NEC Protocol
The modulated carrier is usually derived from 455kHz and is
1/12 of the frequency with 1/3 duty cycle.
When data are transmitted repeatedly, the frame cycle is
107.9ms or 186 period.
A frame consists of a syn pulse, an eight-bit custom code, an
eight-bit inverted custom code, an eight-bit data code and an
eight-bit inverted data code.
IR-10 Programming
IR-10 Control Features:
•
Carrier Frequency: 38KHz
•
Protocol: NEC - Full Repeat
•
System Code(s): 6E (Default) - Multiple Codes
Selected via Key-Press (see Figure 3 and Table 1-2)
Table 1-3: IR Command Code
Figure 5
Key Number
Key Name
Hex Code
1
HOME
02
2
SAVE
1A
3
UP
07
4
LEFT
09
5
STOP
0A
6
RIGHT
0B
7
DOWN
0D
8
PRESET 1
12
9
PRESET 2
13
10
PRESET 3
14
C3
C3
(B)
C2
C1
COM
12V
C1
COM
C2
(A)
(C)
(D)
(E)
(F)