Period (1)
Running hours
(1)
Operation
“
“
Install the drain wear kit.
“
“
Have the safety valve tested.
“
“
Have the operation of sensors, electrical interlockings and
components checked.
“
“
Have the temperature shutdown switch tested.
“
“
Inspect the air receiver.
The air receiver must no longer be used and must be replaced if the
wall thickness is less than the minimum value, specified in the
technical documentation of the air receiver.
“
8000 (3)
If Roto Extend oil is used, change the oil.
“
8000
Replace the thermostatic valve and overhaul the minimum pressure
valve.
“
“
Check and clean the inlet valve. Use the unloader kit.
“
“
Replace the electronic drain.
(1): whichever comes first.
(2): more frequently in a dusty environment
(3): The indicated oil exchange intervals are valid for standard operating conditions (see section
Reference conditions and limitations
) and nominal operating pressure (see section
Compressor
data
). Exposure of the compressor to external pollutants or operation at high humidity combined
with low duty cycles may require a shorter oil exchange interval. Contact your supplier if in doubt.
Important
• Always consult your supplier if a service timer setting has to be changed.
• For the change interval of oil and oil filter in extreme conditions, consult your
Customer Centre.
• Any leakage should be attended to immediately. Damaged hoses or flexible joints
must be replaced.
6.2
Drive motor
General
Keep the outside of the electric motor clean for efficient cooling. If necessary, remove dust with a
brush and/or compressed air jet.
Description
The motor bearings are greased for life.
Instruction book
62
2920 7114 70
Summary of Contents for QRS 10
Page 2: ......
Page 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7114 70 ...
Page 23: ...Electric cubicle UL DOL Instruction book 2920 7114 70 21 ...
Page 51: ...208 230 460V 60Hz Instruction book 2920 7114 70 49 ...
Page 74: ...8 Problem solving Control panel Air outlet valve Instruction book 72 2920 7114 70 ...
Page 75: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7114 70 73 ...
Page 84: ......
Page 85: ......
Page 86: ...No 2920 7114 70 2017 03 Printed in Belgium People Passion Performance www cp com ...