3.19 Calling up/modifying the unit of pressure
The unit of pressure measurement can only be changed when the compressor is stopped.
Starting from the Main screen:
• Press Enter button (7) for 3 seconds to enter the Main menu.
• Select <ProG> and press Enter button (7) to enter the Programming menu.
• After <PASS> blinking, confirm <0> with Enter button (7).
• Scroll Up or Down buttons (4-8) to <diSp> for display settings.
• Press Enter button (7) to enter the submenu.
• Scroll Up or Down buttons (4-8) to <PrES> and press Enter button (7).
• The actually used unit is shown. Possible settings are <bar>, <psi> and <MPa>.
• Scroll Up or Down buttons (4-8) to set the unit of pressure and press Enter button (7) to
confirm. The unit blinks and is saved.
3.20 Calling up/modifying backlight time
The backlight will be activated after pressing any button and for the interval of time set in the
parameter <bC.LG> (in sec).
Starting from the Main screen:
• Press Enter button (7) for 3 seconds to enter the Main menu.
• Select <ProG> and press Enter button (7) to enter the Programming menu.
• After <PASS> blinking, confirm <0> with Enter button (7).
• Scroll Up or Down buttons (4-8) to <diSp> for display settings.
• Press Enter button (7) to enter the submenu.
• Scroll Up or Down buttons (4-8) to <bC.LG> and press Enter button (7).
• The current backlight setting is shown. It is possible to set a value between 0s and 120s.
• Scroll Up or Down buttons (4-8) to set the time of backlight and press Enter button (7) to
confirm. The unit blinks and is saved.
3.21 Activating automatic restart after voltage failure
Description
This function allows the compressor to restart automatically after voltage failure. The activation
can only be done by your supplier. Please contact him for further details.
After any power failure, before restarting, the compressor will wait for a fixed time. When delay
time is running, the display will show the related countdown value (in seconds) as below:
Example countdown delay time of automatic restart after power failure.
Instruction book
42
2920 7114 70
Summary of Contents for QRS 10
Page 2: ......
Page 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7114 70 ...
Page 23: ...Electric cubicle UL DOL Instruction book 2920 7114 70 21 ...
Page 51: ...208 230 460V 60Hz Instruction book 2920 7114 70 49 ...
Page 74: ...8 Problem solving Control panel Air outlet valve Instruction book 72 2920 7114 70 ...
Page 75: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7114 70 73 ...
Page 84: ......
Page 85: ......
Page 86: ...No 2920 7114 70 2017 03 Printed in Belgium People Passion Performance www cp com ...