
Oil filler plug
This procedure should be carried out at the end of the compressor’s service life.
Step
Action
1
Stop the compressor and close the air outlet valve .
2
Switch off the voltage and disconnect the compressor from the mains.
3
Depressurise the compressor by opening plug (3) one turn.
Open condensate drain valve (4) of the air receiver.
4
Shut off and depressurise the part of the air net which is connected to the outlet valve.
Disconnect the compressor from the air net.
5
Drain the oil and condensate circuits.
6
Disconnect the compressor condensate outlet and valve from the condensate net.
Instruction book
60
2920 7114 70
Summary of Contents for QRS 10
Page 2: ......
Page 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7114 70 ...
Page 23: ...Electric cubicle UL DOL Instruction book 2920 7114 70 21 ...
Page 51: ...208 230 460V 60Hz Instruction book 2920 7114 70 49 ...
Page 74: ...8 Problem solving Control panel Air outlet valve Instruction book 72 2920 7114 70 ...
Page 75: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7114 70 73 ...
Page 84: ......
Page 85: ......
Page 86: ...No 2920 7114 70 2017 03 Printed in Belgium People Passion Performance www cp com ...